Wiring the IQ Profiler using the
I
nstall
Q
uick Terminals
The IQ Profiler incorporates innovative
I
nstall
Q
uick wiring
terminals which allow wiring within seconds. Strip approx.
1/4” of insulation from the end of each wire, insert into the
top of the terminal and press the lever down to secure the
wire.
Wiring & Terminal Descriptions
Refer to the wiring diagram and terminal descriptions, connect the
appropriate wire to the corresponding terminal. When you have
finished wiring the terminals seal the opening around the wire entry
hole and any other unused holes with the supplied sealer.
Power (Terminals 1 [+] & 2 [-]): Connect 12 volt regulated or
unregulated power.
N.C. (Terminals 3 & 4) Normally closed alarm relay: Connect
to zone wiring, either detection of an intruder or loss of power will
cause relay to open.
TRBL (Terminal 5) (Optional) Active low (open collector
transistor) auxiliary output, can be configured to provide an
activation on high temperature, low temperature or self test failure.
Using the appropriate jumper settings this output can activate on
any combination of the the above items including all or none.
Tamper (Terminals 6 & 7): With lens cover in place, the contacts
are closed.