background image

17 

K E Y P AD   F U N C T I O N S  

9.

 

Reset System Trouble?  

System troubles display and sound at the keypad.  Correcting 

the trouble will clear most indications, however the following error codes will require manual 
reset: E11; E13; E19; E20 and E22.  (See SYSTEM TROUBLE ERROR CODES for a 
description of error codes). 

 
 
 
 
 

10. 

Reset Sensor Watch Failure  

(Sensor Watch programmed? 

‰

YES  

‰

NO).  

Your system may have been programmed for Sensor Watch, a feature which supervises the 
motion sensors in the system.  If a Sensor Watch failure occurs, a System Trouble E22-NN 
will result, where NN represents the zone number of the sensor in question.  To reset, press 

C

 to clear the display, enter the Function Menu, scroll to Reset Sensor Watch Failure 

and press 

D

.  If you cannot correct the problem, call for service.   

(

Note:  

This function available with GEM-P9600 and GEM-P3200 control panels only.  With the GEM-P816/1632 

panels, "Sensor Watch Fail" is reset by "Reset System Trouble" function).

 

 
 

 
 

 
 

 
 

 
 

 
 

 

11. 

Start Exit Time?  

(Optional)  (Start Exit Time programmed? 

‰

YES  

‰

NO) 

In Commercial Burglary systems, exit delay may have been programmed to start after a 
central-station “ringback” (verification) signal has been received.  If the ringback tone has not 
been received within about 30 seconds after arming, a communication problem may exist.  
Use this function to start exit delay manually, then exit the premises immediately.  Be sure to 
have your alarm specialist check communications with the central station as soon as 
possible.   

(

Note:  

This function available with GEM-P9600 and GEM-P3200 control panels only).

 

CHIME 

 

 

 

 

09 

CHIME 

 

 

 

 

10 

CHIME 

 

 

 

 

11 

Содержание Gemini GEM-RP4C

Страница 1: ...ING GUIDE for your GEM RP4C and GEM RP4RFC KEYPAD NAPCO 2006 ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI A 1 2 3 B 4 5 6 C 7 8 9 0 E F G J INTERIOR 96 NEXT YES PRIOR NO AREA 96INTERIOR BYPASS OI2...

Страница 2: ...ighest industry standards To assure optimum safety and security familiarize yourself with this equipment Periodically check its condition and state of readiness by testing it at least once a week in b...

Страница 3: ...S 21 PROGRAMMING USER CODES 22 GLOSSARY 24 SYSTEM TROUBLE ERROR CODES 27 TROUBLESHOOTING 31 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS J FOR SERVICE CALL __________________ CENTRAL STATION ________...

Страница 4: ...NDICATORS ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI A 1 2 3 B 4 5 6 C 7 8 9 0 E F G J INTERIOR 96 1 2 3 4 5 6 7 12 8 9 10 11 13 NEXT YES PRIOR NO AREA 96 RESET INTERIOR FIRE INSTANT CANCELLED T...

Страница 5: ...Keys 1 9 0 Used to enter codes zone numbers etc ON OFF Button Entry key Causes the entered code or selected function to be executed INTERIOR Button 1 Bypasses all Interior Zones simultaneously to all...

Страница 6: ...dicating an error Re enter your code 3 Leave the premises Leave through the exit door before the exit time expires Priority Arming If you attempt to arm the system with a faulted Zone a 3 second tone...

Страница 7: ...s may be armed while others remain disarmed Manager s Mode The Manager s Mode allows the user to arm disarm other areas in a partitioned system To arm a different area 1 Press the numerical key repres...

Страница 8: ...d for Automatic Interior Bypass which allows it to recognize that you have armed the system and remained in the house prompting it to automatically adjust the interior protection accordingly If you ar...

Страница 9: ...Emergency programmed YES NO Easy Exit Optional Easy Exit programmed YES NO Your system may have been programmed for Easy Exit which allows a user to exit the premises while the system is armed By acti...

Страница 10: ...call authorities from a neighbor s phone To silence an audible alarm 1 Enter your code and press J After the system is disarmed the window will continue to display the number s of the zone s violated...

Страница 11: ...icator light will be on After the alarm condition is corrected thermostat cooled down smoke cleared from detector etc pressing C again will reset the keypad within about 10 seconds Fire Zone Trouble T...

Страница 12: ...with all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not s...

Страница 13: ...13 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Страница 14: ...es because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen...

Страница 15: ...no activity is detected for longer than one minute 1 Display Zone Status Displays the zone number of zones that are not secured Press the NEXT and PRIOR Buttons as displayed on screen to scroll fault...

Страница 16: ...l zones required for GEM P3200 9600 panels GEM P816 1632 panels will auto scroll 7 Activate Chime The Chime Mode will sound a tone at the keypad when the programmed zone is opened while disarmed To de...

Страница 17: ...set Sensor Watch Failure and press D If you cannot correct the problem call for service Note This function available with GEM P9600 and GEM P3200 control panels only With the GEM P816 1632 panels Sens...

Страница 18: ...ally after a delay period of 1 to 4 hours To Delay Arm the system With Function 16 in the window enter the desired Delay Arming time in hours 1 2 3 or 4 followed by D At the end of this 1 4 hour Delay...

Страница 19: ...to turn the displayed group on or off press NEXT E to proceed to the next group or PRIOR F to scroll back to the previous group Press C when done Relay Group 01 ____________________________________ Re...

Страница 20: ...econds at your option by consulting with your in staller Regular Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report restore...

Страница 21: ...ntral station acknowledges receipt ringback exit delay will start If ringback is not heard within about 30 seconds a communication problem may exist call for service Function 11 Start Exit Time may th...

Страница 22: ...ll beep while in the User Program Mode Programming Reprogramming a User Code 1 Press A followed by the the 2 digits of the user number to be programmed Example for User 4 enter 04 2 Press A followed b...

Страница 23: ...e Notes If the system contains more than one keypad only the keypad designated No 1 may be used for programming if in doubt which is No 1 ask your installer While in Program Mode the ARMED and STATUS...

Страница 24: ...rough Managers Mode Arming Disarming Turning the system on off by entering your code at the keypad then pressing J Battery Backup power source in the control panel enclosure to provide protection in t...

Страница 25: ...port A transmission to a central station notifying of a change in the status of the system alarm trouble low battery etc RF Low Battery Wireless systems only Weak transmitter battery RF Supervisory Wi...

Страница 26: ...ce through the normal exit entry door first Fire Zone Detects fire alarms or trouble conditions Interior Zones Circuits within the premises usually including space protection devices interior doors et...

Страница 27: ...ng company for service as soon as possible Trouble Indication System Trouble Condition Action E 01 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is p...

Страница 28: ...B The replacement battery for the GEM SMK is the Duracell MN1604 9 Volt Alkaline 2 required The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warning Replace batteries only with t...

Страница 29: ...service E 15 NN RF Transmitter Tamper Wireless Transmitter Tamper Cover removed NN Transmitter Number Call installing company for service E 16 NN Wireless Receiver Jam A problem has been detected with...

Страница 30: ...talling company for service E 24 Service Message The system is in need of a preventive maintenance service call E 27 00 Printer Failure Call installing company for service E 39 00 Receiver Capacity Er...

Страница 31: ...the scrolling error codes which represent the trouble Press C and you will now be able arm to the system but the trouble must be fixed as soon as possible See Page 7 27 The Fire Alarm is sounding and...

Страница 32: ...any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system ma...

Отзывы: