NAPCO Gemini GEM-P3200 Скачать руководство пользователя страница 37

L

 NAPCO Security Systems  

X

  GEM-P3200 Programming Instructions 

 

Page 37

 

WI818G  10/05 

RIGHT 

blank (•) 


OPTION 

Not Used 

Area 1 
Area 2 

KEYPAD AREA 

ASSIGNMENT  

KEYPAD OPTIONS (ADDRESS 2425-2446) 

KEYP

A

D

 OPTIONS 

[Default = blank (•) blank (•)] 

LEFT 

RIGHT 

blank (•) 

 

ADDRESS 2428  

Keypad 4 Type  

& Area            

Assignment 

[Default = blank (•) 1] 

LEFT 

RIGHT 

 

 

ADDRESS 2425  

Keypad 1 Type  

& Area            

Assignment 

[Default = blank (•) blank (•)] 

LEFT 

RIGHT 

blank (•) 

 

ADDRESS 2426  

Keypad 2 Type  

& Area            

Assignment 

[Default = blank (•) blank (•)] 

LEFT 

RIGHT 

blank (•) 

 

ADDRESS 2427  

Keypad 3 Type  

& Area            

Assignment 

[Default = blank (•) blank (•)] 

LEFT 

RIGHT 

blank (•) 

 

ADDRESS 2429  

Keypad 5 Type  

& Area            

Assignment 

[Default = blank (•) blank (•)] 

LEFT 

RIGHT 

blank (•) 

 

ADDRESS 2430  

Keypad 6 Type  

& Area            

Assignment 

[Default = blank (•) blank (•)] 

LEFT 

RIGHT 

blank (•) 

 

ADDRESS 2431  

Keypad 7 Type  

& Area            

Assignment 

KEYPAD TYPE & AREA ASSIGNMENT: 

Up to 7 keypads may be programmed, if they 

are connected. 
 

NOTE:

 See Keypad Configuration Mode. By default from the factory, each keypad is 

configured as number 1.  

1. Select keypad type & area assignment for each keypad from the tables shown. 

2. Enter in corresponding right and left digit address locations above.   

LEFT 

OPTION 

blank 

(•) 

Burg Keypad 

Wizard Keypad 

KEYPAD TYPE  

KEYPAD NUMBER 

 

KEYPAD OPTIONS 

ADDR 

KEYPAD 

FIRE 

KEYPAD 

AUXILIARY 

KEYPAD 

PANIC 

Rem. Acc. 

Only * 

AMBUSH 

EASY 

ARMING 

PANEL 

ACCESS 

TOUR  

STATION 

 

2440 

default ON  default ON  default ON 

 

default ON 

 

 

 

2441 

default ON  default ON  default ON 

 

default ON 

 

 

 

2442 

default ON  default ON  default ON 

 

default ON 

 

 

 

2443 

default ON  default ON  default ON 

 

default ON 

 

 

 

2444 

default ON  default ON  default ON 

 

default ON 

 

 

 

2445 

default ON  default ON  default ON 

 

default ON 

 

 

 

2446 

default ON  default ON  default ON 

 

default ON 

 

 

 

[Defaults as noted for address 2440-2446] 

KEYPAD OPTIONS:

  Select options for any of the 7 keypads. 

* Note:  

For Remote Access Control only (no Arm/Disarm capability). 

 

1.     Select the desired option entering the option number (1-8) for each digit. 

2.     Enter corresponding option number in address location. 

3.     Press 

U

 or 

D

 to save. 

NOTE:

  Dark shaded data value box shows option not available. 

Содержание Gemini GEM-P3200

Страница 1: ...ield K Series GEM K1CA G E M I N I SYSTEM READY 01 01 06 12 00 AM ARMED COMPUTERIZED SECURITY SYSTEM STATUS R 1 2 3 B 4 5 6 C 7 8 9 0 U NEXT YES P PRIOR NO Q AREA G PROGRAMMING INSTRUCTIONS R Classic...

Страница 2: ...t is recommended that all keypads either be all classic or all K Series both keypad types should not be used in one alarm system NAPCO Security Group Inc 333 Bayview Avenue Amityville New York 11701 F...

Страница 3: ...AL SYSTEM TROUBLE REPORTING OPTIONS ADDRESS 1082 1116 28 AREA SYSTEM TROUBLE REPORTING OPTIONS ADDRESS 1120 1137 29 ZONE OPTIONS ZONES 1 16 ADDRESS 1200 1386 30 ZONE OPTIONS ZONES 17 32 ADDRESS 1402 1...

Страница 4: ...the Dealer Program Mode wherein data is entered at the keypad by location This mode is accessed from the Easy Menu Driven Program Mode by pressing the C button at any time User Program Mode Keypad Pr...

Страница 5: ...the Dealer Program Mode press the C button to enter the Direct Address Program Mode b access Location 4091 Clear Program c press the U button and start over 1 Press EEEEEE R 2 Press Q Until ACTIVATE...

Страница 6: ...n designated as Fire Zones can be programmed as 2 Wire Fire zones JP3 must be set to 2 WF position for 2 wire fire for zones 7 8 refer to Installation Instructions Local or Central Station Reporting S...

Страница 7: ...zones to be Sensor Watch zones Valid entries are from 01 to 48 Directly enter each zone number including leading zeros Press U to save and then repeat for any additional zone s Press the NEXT YES but...

Страница 8: ...ss G 1 through G 5 for letters B F respectively Pre Dial Delay D G 4 Dial Tone Detection E G 5 Press U to save and press the NEXT YES button to proceed NOTE Central Station Receiver 2 and 3 Telephone...

Страница 9: ...Press G1 through G4 for letters B E Press U to save and press the NEXT YES button to proceed Direct Entry Central Station Account ____ Direct Entry See WI for Info Rcvr Format 0 DATA ENTRY CS RECEIVE...

Страница 10: ...r entries greater than 9 press the G1 buttons through the G5 buttons for B through F respectively For Keypad Access Control press the R button once again to program applicable keypads Refer to the tab...

Страница 11: ...LANATION Disabled User Code not active in this area Blocked View Allows User Code to block another code from being viewed by another user An unblocked code cannot view a blocked code but a blocked cod...

Страница 12: ...0 9 Note Press the 0 button for a zero No blank spaces in between leave blank any trailing boxes Refer to the tables below and WI1221 for the available User Level data entries Enter the level data in...

Страница 13: ...which transmitter is assigned 0 to disable keyfob 1 or 2 The 6 digit RF ID and 1 digit checksum number printed on the transmitter and box The Aux 1 Option see keyfob aux 1 aux 2 options The Aux 2 Opti...

Страница 14: ...Press U to save Press the NEXT YES button to proceed Enter Time Press R to set cursor Enter the current time in format HH MMA P where HH hours 01 12 MM minutes 00 59 Select AM or PM by pressing any nu...

Страница 15: ...Bit Format Settings such as Zone Features display and accept data in number format For example Zone Features are turned on by the pressing of keypad buttons 1 through 8 with the activated Zone s displ...

Страница 16: ...ically moving to the right upon each key press EXAMPLE DECIMAL Format with the GEM RP1CAe2 GEM K1CA Program Abort Delay to be 15 seconds DETERMINE THE DATA ENTRIES Referring to SYSTEM DELAYS TIMEOUTS...

Страница 17: ...below EXAMPLE HEXADECIMAL Format with the GEM RP1CAe2 GEM K1CA Program an Ambush CS Reporting Code to be 1B DETERMINE THE DATA ENTRIES Referring to CS REPORTING CODES in the Programming Worksheets tha...

Страница 18: ...s PCD Windows software following any keypad programming and that the PCD Windows s error check feature be utilized to reduce the possibility of programming omissions or conflicts 3 Keep the Keypad Pr...

Страница 19: ...ty of 1 sec so a time of 1 second may actually timeout IMMEDIATELY Select delay timeout 0 255 seconds EXIT ENTRY DELAYS Apply only to zones programmed with the following options Exit Entry 1 Exit Entr...

Страница 20: ...address locations 2 Valid entries are 0 9 Note Also Access Control on Aux Output Address 2418 and Aux Output Access Control Timeout Address 2402 must both be enabled LEFT RIGHT ADDRESS 0495 Ambush Co...

Страница 21: ...the zone and 1234 is the Subscriber ID number For example if the Leading Digits are programmed as 98 the Pager report will now appear as 983 022 1234 1 Enter in 1st and 2nd Leading Digits in right di...

Страница 22: ...mes 15 rings 1 Enter digits only 2 Valid entries are 003 015 NOTE Default is 15 Rings Press U or D to save CALLBACK TELEPHONE NUMBERS Enter telephone numbers to be used when downloading from a compute...

Страница 23: ...83 0684 0685 CS TELCO 1 SUBSCRIBER EVENT ID NUMBERS AREA 2 ADDRESS 0686 0689 DIGITS 1 4 0686 0687 0688 0689 SYSTEM ADDRESS 0714 0717 DIGITS 1 4 0714 0715 0716 0717 AREA 1 ADDRESS 0720 0723 DIGITS 1 4...

Страница 24: ...CS TELCO SUBSCRIBER ID NUMBERS Enter the Subscriber Opening Closing and Event ID Numbers for any of the 3 CS Receivers 1 Enter 3 or 4 digits depending on the CS receiver format for each subscriber nu...

Страница 25: ...ADDRESS 0900 0904 KEYPAD REPORTING CODES Ambush Panic Fire Auxiliary Tamper CAUTION For all 2 Digit Reporting Formats see CS Receiver Format Options use the following Example The 2 digit reporting co...

Страница 26: ...ire Panic Burglary Hold up ZONE REPORT CODE OPTIONS DATA ENTRIES NOTE Zones 1 8 are included in the control panel and Zones 9 32 are EZM Zones Zones 33 48 are wireless See Address 2555 2560 to enable...

Страница 27: ...ng Telco 1 1043 1044 User Opening Telco 3 1056 1057 User Closing Telco 3 1069 1070 Enable Users to Report USERS 17 24 USERS 25 32 ADDR U17 U18 U19 U20 4 U21 U22 U23 U24 ADDR U25 U26 U27 U28 U29 U30 U3...

Страница 28: ...emetry Failure RSRVD RSRVD RSRVD RSRVD 1 2 3 4 5 6 7 8 Burglary Alarm Output 1094 Pulsed Burg Output 1095 Fire Output Lug E9 1096 Reset Relay 1097 Auxiliary Relay 1098 Report Event Telco 1 1099 Defaul...

Страница 29: ...TO OPEN FAIL TO CLOSE RSRVD 1 2 3 4 5 6 7 8 Pulsed Burg Output 1120 Default ON Burglary Output 1121 Default ON Default ON Fire Output Lug E9 1122 Reset Relay 1123 Auxiliary Relay 1124 Report Alarm Te...

Страница 30: ...RPT Trouble Restore Tel 1 1230 1330 RPT Alarm Tel 3 1235 1335 RPT Alarm Restore Tel 3 1236 1336 RPT Trouble Tel 3 1237 1337 RPT Trouble Restore Tel 3 1238 1338 No EOL Resistor 1239 1339 Sensor Watch...

Страница 31: ...1526 RPT Alarm Tel 1 1427 1527 RPT Alarm Restore Tel 1 1428 1528 RPT Trouble Tel 1 1429 1529 RPT Trouble Restore Tel 1 1430 1530 RPT Alarm Tel 3 1435 1535 RPT Alarm Restore Tel 3 1436 1536 RPT Trouble...

Страница 32: ...1726 RPT Alarm Tel 1 1627 1727 RPT Alarm Restore Tel 1 1628 1728 RPT Trouble Tel 1 1629 1729 RPT Trouble Restore Tel 1 1630 1730 RPT Alarm Tel 3 1635 1735 RPT Alarm Restore Tel 3 1636 1736 RPT Trouble...

Страница 33: ...he zones if YES is entered for REPORT ALL ZONES TO CENTRAL ZONES Y N Entry Exit 1 and Chime are enabled for zone numbers entered in EXIT ENTRY ZONES Exit Entry Follower and Interior Bypass are enabled...

Страница 34: ...ions Default Option OFF 1 Interior 1 Normally Bypassed OFF 2 Enable Exit Delay Restart OFF 3 Reset Day Zone with Arm Disarm Only OFF 4 Enable Local Alarm on First Zone AND Trip OFF 5 Disable Keypad Fu...

Страница 35: ...or this address contingent on EZ Menu selections 2422 System Options 3874 System Options Default Option Default Option ON 1 Pulse Burg Output Cadence OFF 1 Enable GEM PRINT OFF 2 Wireless Smoke Low Ba...

Страница 36: ...c Dial Tone Detect Note Right digit is RESERVED not used Enter data in left digit only SYSTEM OPTIONS ADDRESS 3882 3901 3903 3905 4084 Telephone Dialing Prefix Digits 1 20 ADDRESS 3882 3901 RIGHT DIGI...

Страница 37: ...ad is configured as number 1 1 Select keypad type area assignment for each keypad from the tables shown 2 Enter in corresponding right and left digit address locations above LEFT OPTION blank Burg Key...

Страница 38: ...Entry Zone 2751 2756 Door Ajar Zone 2752 2757 ADDR Area for Door 2 2758 Reserved 2753 2759 Reserved 2754 2780 ACM Global Flags Default Option OFF 1 Enable Two Swipe Arming OFF 2 Enable NAPCO Proprieta...

Страница 39: ...or 2 2787 Default blank blank from address 2784 2787 ACM DOOR AREA OPTIONS 1 Select the desired option entering the option number 1 3 for each address 2 Enter corresponding option number in address lo...

Страница 40: ...or Keypad and 1 for ACM The right digit nibble determines the home area 1 or 2 of the specified device Press U or D to save KEYPAD HOME AREA ACM DOOR 1 AREA HEX ADDRESS 2425 2431 KEYPAD HOME AREA ACM...

Страница 41: ...try time delay display or if a valid user code is entered at the keypad while the system is armed 2 Press U or D to save NOTE Dark shaded data value box shows option not available ADDRESS 2423 SYSTEM...

Страница 42: ...8 ON 15 2469 ON 16 2470 ON 17 2471 18 2472 19 2473 20 2474 21 2475 22 2476 23 2477 24 2478 25 2479 26 2480 27 2481 28 2482 29 2483 30 2484 31 2485 32 2486 33 2487 34 2488 35 2489 36 2490 37 2491 38 24...

Страница 43: ...Groups of 4 Zones each may be programmed depending on the number of zones used and which EZM modules are connected Each group represents 4 zones 1 Select EZM type from the table shown 2 Enter either...

Страница 44: ...LOGGING ADDRESS 3184 REMOTE ACCESS LOGGING Enable logging of every keypad access event 1 Select the desired option entering the option number 1 7 for each digit 2 Enter corresponding option number in...

Страница 45: ...inary Bit Format NOTE See Direct Address Programming Example on page 15 3 Press U or D to save AREA OUTPUT CONTROL OUTPUT SILENCED TURNED OFF DISARMING AREA 1 TURNS OFF AREA OUTPUT ADDR A1 A2 1 2 Burg...

Страница 46: ...in 680 min 690 min 700 min 2550 min 42 Hr 30 min RF SUPERVISORY TIMERS RF SUPERVISORY TIMERS RF Supervisory Timers may be programmed for each type of transmitter used A transmitter will send a transmi...

Страница 47: ...ry 11 3788 2840 2841 2842 2843 L R L R L R L R ADDRESS 3789 2844 2847 RELAY entry 12 3789 2844 2845 2846 2847 L R L R L R L R ADDRESS 3790 2848 2851 RELAY entry 13 3790 2848 2849 2850 2851 L R L R L R...

Страница 48: ...cal to the relay entry address table number in the selected address table s above STEP 3 TIMEOUTS Each relay event can be assigned a timeout depending on Alarm Type option If Alarm Type is selected fo...

Страница 49: ...15 1 blank 16 1 1 17 1 2 18 1 3 19 1 4 20 1 5 21 1 6 22 1 7 23 1 8 24 Note blank blank option affects the relay with the same entry number All other options affect the relay number specified Ex Suppo...

Страница 50: ...2 F Zone 40 3 blank Zone 41 3 1 Zone 42 3 2 Zone 43 3 3 Zone 44 3 4 Zone 45 3 5 Zone 46 3 6 Zone 47 3 7 Zone 48 C blank Area 1 disarm C 1 Area 2 disarm 6 8 Area 1 Keypad Ambush 6 9 Area 1 Keypad Panic...

Страница 51: ...ENT CONDITION OPTIONS Each relay event can be assigned an alarm type and an activation condition also select a timeout type for each 5A Select Alarm Type and Timeout Type from Table 5A below enter in...

Страница 52: ...configure address jumpers as Keypad 1 See WI1184 NOTE For ease of programming it is recommended that a GEM K1CA or GEM RP1CAe2 be used as Keypad 1 A new GEM K1CA and a new GEM RP1CAe2 are automaticall...

Страница 53: ...r buttons The cursor will then advance to the User Code and read the existing code if any Enter the new User Code using the number buttons 0 9 If an old code is displayed program over it To erase the...

Страница 54: ...released during the 1 second window the current character will change to upper case Press U to save To proceed to the next description place the cursor under the Zone Number e g 1 and press the number...

Страница 55: ...from Pins 1 2 top two to Pins 2 3 bottom two NOTE See Wiring Diagram on page 68 2 After about 15 seconds the display will read XX OUT OF SYSTEM where XX indicates the keypad address 3 Press 11123 R an...

Страница 56: ...duced to 50mS as follows 1 Of the following circle the number s in parentheses associated with the zone s to be changed Zone 1 1 Zone 2 2 Zone 3 4 Zone 4 8 2 Add up the circled numbers 3 At the keypad...

Страница 57: ...1022 22 CALLBACK TELEPHONE NUMBER 1 AND 2 22 CANCEL A CODE 11 CANCEL NEXT TEST TIMER ON ANY REPORT ADDRESS 1027 25 CANCELING A CODE 11 CENTRAL STATION RECEIVER 1 ACCOUNT NUMBER 9 CENTRAL STATION RECE...

Страница 58: ...A FAR ADDRESS 3905 35 ENABLE EXIT DELAY RESTART ADDRESS 2419 34 ENABLE FACILITY CODE ADDRESS 2780 38 ENABLE GEM PRINT ADDRESS 3874 35 ENABLE KEYPAD BLANKING ADDRESS 2423 41 ENABLE KEYPAD TIME DATE DIS...

Страница 59: ...R OF RELAY BOARD MODULES ADDRESS 3777 51 NUMBER OF RF RECEIVERS ADDRESS 3776 46 NUMBERING KEYPADS 55 OPENING REPORT ONLY AFTER ALARM REPORT ADDRESS 2417 34 OPENING CLOSING REPORTING CODES ADDRESS 0864...

Страница 60: ...ION 4 TELCO FAIL ONLY WHEN ARMED ADDRESS 2420 35 TELEPHONE DIALING PREFIX DIGITS 1 20 ADDRESS 3882 3901 36 TELEPHONE LINE TEST DELAY ADDRESS 2414 19 TELEPHONE NUMBERS CS RECEIVER 22 3 1 WITH EXTENDED...

Страница 61: ...21 ADDRESS 0526 SINGLE DIGIT ONLY 21 ADDRESS 0526 SUM CHECK 21 ADDRESS 0526 3 1 WITH EXTENDED RESTORES 21 ADDRESS 0527 0546 CS RECEIVER TELEPHONE NUMBERS 22 ADDRESS 0550 CS RECEIVER 2 FORMAT 21 ADDRES...

Страница 62: ...027 CS SYSTEM REPORT OPTIONS 25 ADDRESS 1027 DISABLE WAIT FOR HANDSHAKE 25 ADDRESS 1027 DISABLE WAIT FOR SILENCE 25 ADDRESS 1027 HANDSHAKE FOR LOCAL TELEMETRY 25 ADDRESS 1027 TOUCH TONE DIALING ONLY 2...

Страница 63: ...DDRESS 2418 START EXIT DELAY AFTER RINGBACK 34 ADDRESS 2418 SUPPRESS BYPASS ICON WHEN ARMED 34 ADDRESS 2418 SYSTEM OPTIONS 34 ADDRESS 2419 DISABLE ANSWERING MACHINE DOWNLOAD 34 ADDRESS 2419 DISABLE AU...

Страница 64: ...OPTIONS 37 ADDRESS 2455 2502 USER AREA OPTIONS 42 ADDRESS 2555 2576 EZM GROUP OPTIONS 43 ADDRESS 2650 2651 AREA ARMING OPTIONS 44 ADDRESS 2700 2739 AREA OUTPUT CONTROL OPTIONS 45 ADDRESS 2740 2769 ACM...

Страница 65: ...T ENTER EXIT TEST MODE 35 ADDRESS 3905 DISABLE CALL WAITING ON FIRST ATTEMPT 35 ADDRESS 3905 ENABLE AMBUSH IN USER ASSIGNMENT CODE TYPE 35 ADDRESS 3905 ENABLE BELL ON EXIT ERROR 35 ADDRESS 3905 ENABLE...

Страница 66: ...X GEM P3200 Programming Instructions L NAPCO Security Systems Page 66 WI818G 10 05 NOTES...

Страница 67: ...L NAPCO Security Systems X GEM P3200 Programming Instructions Page 67 WI818G 10 05 NOTES...

Страница 68: ...X GEM P3200 Programming Instructions L NAPCO Security Systems Page 68 WI818G 10 05 GEM P3200 WIRING DIAGRAM...

Отзывы: