20 

Your alarm specialist may have 

programmed your system to be monitored 
by a central station.  The built-in digital 
communicator can transmit emergency 
signals and status reports to the central 
station 24 hours a day. 

 

Communicator Features 

Abort Delay.

 Ask your installer which of 

your zones have Abort Delay, a delay 
that enables you to reset the system 
before it communicates to the central 
station.  Your system has a SIA CP-01 
required Abort Delay of 30 seconds.  It 
may be removed or increased up to 45 
seconds (at your option) by consulting 
with your installer.  

Note:  

If an alarm 

signal is cancelled during the Abort De-
lay or cancelled after the report is sent 
(and an acknowledgement of the can-
cellation is received), a "

C

" will appear in 

the keypad window. 

Regular Burglary 

(Non-24-Hour) Zone 

reports are aborted by disarming within 
the delay period. 

24 - H o ur   Z o n es 

a nd   z on es 

programmed to report restores must be 

restored first, then the panel armed and 
disarmed, all within the delay period. 

 

Opening and/or Closing Reporting.  

Your system can notify the central station 
every time it is disarmed or armed.  Any or 
all of up to 96 different users can each be 

identified.  If your system reports on arming 
(Closing Report), the central station will 
acknowledge arming.  This will signal at the 
keypad as a “ringback” beep.  

Note:

 If the 

ringback signal is not heard, call for service. 

 

C E N T R AL   S T AT I O N   M O N I T O R I N G  

Содержание Gemini GEM-DXRP3

Страница 1: ...1 OPERATING GUIDE for your GEM DXRP3 KEYPAD NAPCO 2006 OI324 11 06...

Страница 2: ...y standards To assure optimum safety and security familiarize yourself with this equipment Periodically check its condition and state of readiness by testing it at least once a week in both the ac bat...

Страница 3: ...S 21 PROGRAMMING USER CODES 22 GLOSSARY 24 SYSTEM TROUBLE ERROR CODES 27 TROUBLESHOOTING 31 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS J FOR SERVICE CALL __________________ CENTRAL STATION ________...

Страница 4: ...4 96 INTERIOR BYPASS FIRE TBL SYS TBL CHIME KEYPAD CONTROLS INDICATORS 7 12 8 9 10 11 2 4 5 6 1 3 13...

Страница 5: ...1 Resets various system troubles displays etc See text 2 Resets residential smoke detectors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ON OFF Button Entry key Causes the entered code or...

Страница 6: ...e the premises Leave through the exit door before the exit time expires Priority Arming If you attempt to arm the system with a faulted Zone a 3 second tone will sound at the keypad and P will display...

Страница 7: ...rs remain disarmed Manager s Mode The Manager s Mode allows the user to arm disarm other areas in a partitioned system To arm a different area 1 Press the numerical key representing the other area num...

Страница 8: ...r Bypass which allows it to recognize that you have armed the system and remained in the house prompting it to automatically adjust the interior protection accordingly If you arm the system and remain...

Страница 9: ...Emergency programmed YES NO Easy Exit Optional Easy Exit programmed YES NO Your system may have been programmed for Easy Exit which allows a user to exit the premises while the system is armed By acti...

Страница 10: ...call authorities from a neighbor s phone To silence an audible alarm 1 Enter your code and press J After the system is disarmed the window will continue to display the number s of the zone s violated...

Страница 11: ...ll be on After the alarm condition is corrected thermostat cooled down smoke cleared from detector etc pressing C again will reset the keypad within about 10 seconds Fire Zone Trouble The system is co...

Страница 12: ...with all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not s...

Страница 13: ...13 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Страница 14: ...es because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen...

Страница 15: ...ts normal operating mode if no activity is detected for longer than one minute Display Zone Status Displays the zone number of zones that are not secured Press the NEXT and PRIOR Buttons as displayed...

Страница 16: ...sound a tone at the keypad when the programmed zone is opened while disarmed To deactivate the Chime Mode execute Function 7 once again Note The Chime Mode is disabled while armed 8 Activate Watch Mo...

Страница 17: ...To reset press C to clear the display enter the Function Menu scroll to Reset Sensor Watch Failure and press D If you cannot correct the problem call for service 11 Start Exit Time Optional Start Exit...

Страница 18: ...4 hours To Delay Arm the system With Function 16 in the window enter the desired Delay Arming time in hours 1 2 3 or 4 followed by D At the end of this 1 4 hour Delay Arming period the siren will sou...

Страница 19: ...f press NEXT E to proceed to the next group or PRIOR F to scroll back to the previous group Press C when done Relay Group 01 ____________________________________ Relay Group 02 _______________________...

Страница 20: ...lled during the Abort De lay or cancelled after the report is sent and an acknowledgement of the can cellation is received a C will appear in the keypad window Regular Burglary Non 24 Hour Zone report...

Страница 21: ...all for service Function 11 Start Exit Time may then be used to manually start the exit delay however reporting capability may be sacrificed If your system does not report or the ringback feature was...

Страница 22: ...g Reprogramming a User Code 1 Press A followed by the the 2 digits of the user number to be programmed Example for User 4 enter 04 2 Press A followed by the new User Code Note User Codes may be up to...

Страница 23: ...ode 5 Press C to exit the Program Mode Notes If the system contains more than one keypad only the keypad designated No 1 may be used for programming if in doubt which is No 1 ask your installer While...

Страница 24: ...Turning the system on off by entering your code at the keypad then pressing J Battery Backup power source in the control panel enclosure to provide protection in the event of a power failure BYPASS Bu...

Страница 25: ...port A transmission to a central station notifying of a change in the status of the system alarm trouble low battery etc RF Low Battery Wireless systems only Weak transmitter battery RF Supervisory Wi...

Страница 26: ...ce through the normal exit entry door first Fire Zone Detects fire alarms or trouble conditions Interior Zones Circuits within the premises usually including space protection devices interior doors et...

Страница 27: ...uble Condition Action E 01 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker otherwise call i...

Страница 28: ...B The replacement battery for the GEM SMK is the Duracell MN1604 9 Volt Alkaline 2 required The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warning Replace batteries only with t...

Страница 29: ...service E 15 NN RF Transmitter Tamper Wireless Transmitter Tamper Cover removed NN Transmitter Number Call installing company for service E 16 NN Wireless Receiver Jam A problem has been detected with...

Страница 30: ...talling company for service E 24 Service Message The system is in need of a preventive maintenance service call E 27 00 Printer Failure Call installing company for service E 39 00 Receiver Capacity Er...

Страница 31: ...the scrolling error codes which represent the trouble Press C and you will now be able arm to the system but the trouble must be fixed as soon as possible See Page 7 27 The Fire Alarm is sounding and...

Страница 32: ...any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system ma...