P R O G R AM M I N G   ( O P T I O N A L )  

Programming Example: 

Program the User 3 Code to “3784”: 

1.

 Select the Program Mode as follows: 

(a) 

Enter your User Code, followed by 

A

(b) 

Answer NO (press 

F

 

) repeatedly until “TurnOn 

Prog Yes/No” is displayed, then press YES (

E

).  

The display will briefly read:  “UPXXXX” then 
"User01" (User 1's Code). 

2.

 

Press 

03

 for User No. 3. 

3.

 

Press 

A

 

to advance to the User Code screen. 

4.

 

Press 

3784

 to program the code.  

If any other digits are left over from a previous User-3 
Code, delete each by pressing 

G

 

0

.   

Note:  

Do not attempt to program the "OPTion" or 

"ACCess" screens (if they display) as they will not be 
saved.

 

5.

 

Press 

J

 to save the code. 

6.

 

Press 

C

 to exit the Program Mode. 

Notes:

 

Note:  

Duplicate Codes are not allowed; therefore a dupli-

cate Code entered in the LCD Window will erase when 

D

 is 

pressed. 

If the system contains more than one keypad, only the 
keypad designated “No. 1” may be used for programming 
(if in doubt which is No. 1, ask your installer). 

While in Program Mode, the ARMED and STATUS lights 
remain off and burglar and fire alarm functions are 
disabled. 

In selecting your codes, do not program repetitive 
numbers (1111), consecutive numbers (1234), your birth 
date, address, or other obvious combinations.  Choose a 
code of up to six digits (a minimum of four is 
recommended, and required in UL installations).  If the 
keypad detects no Program Mode activity for more than 4 
minutes, a tone will sound.  Press 

C

 to silence.  

Содержание GEM-DXRP2

Страница 1: ...1 OPERATING GUIDE for your GEM DXRP2 KEYPAD NAPCO 2006 OI323 11 06 AC ON READY...

Страница 2: ...the highest industry standards To assure optimum safety and security familiarize yourself with this equipment Periodically check its condition and state of readiness by testing it at least once a wee...

Страница 3: ...PROGRAMMING 25 KEYPAD MESSAGES 28 GLOSSARY 32 SYSTEM TROUBLE ERROR CODES 35 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS J FOR SERVICE CALL _____________________ CENTRAL STATION _____________________...

Страница 4: ...4 KEYPAD CONTROLS INDICATORS 7 12 8 9 10 11 AC ON READY 2 4 5 6 1 3...

Страница 5: ...system troubles displays etc See text 2 Resets residential smoke detectors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ON OFF Button Entry key Causes the entered code or selected functio...

Страница 6: ...locate or repair the problem yourself call for assistance If you cannot get immediate help bypass the problem zone s from the system by pressing B then the zone number or vice versa Note Bypassed zon...

Страница 7: ...ne in trouble Be sure to have the trouble repaired as soon as possible Silence Alarm If you enter your code while the alarm is sounding the message CAN T ArmSil will be displayed The system will silen...

Страница 8: ...other areas without the system status display This is NOT a high security feature To arm any area 1 Press the numerical key representing the area number 2 Press G followed by J In effect you will now...

Страница 9: ...tic Interior Bypass programmed YES NO Your system may have been programmed for Automatic Interior Bypass which allows it to recognize that you have armed the system and remained in the house prompting...

Страница 10: ...o indicate instant protection Emergency Buttons Only available if programmed The Blue Emergency Buttons 7 8 9 if programmed are always active whether the system is armed or disarmed The emergency sign...

Страница 11: ...an invalid code the keypad display Wrong Code Re enter your code immediately Alarm Indication Silencing an Alarm If the red ARMED light is flashing and ALARM is displayed an alarm occurred while you...

Страница 12: ...y Zone Day Zone s programmed YES NO A Day Zone is used to monitor a secured exit door window foil etc A problem on this type of burglary zone will cause a DAY ZN dis play followed by ZONEXX xx represe...

Страница 13: ...dence of a fire enter your User Code and press J to turn off the alarm 4 Check smoke detector s If a smoke detector tripped its red alarm indicator light will be on After the alarm condition is correc...

Страница 14: ...th all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not sto...

Страница 15: ...15 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Страница 16: ...es because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen...

Страница 17: ...ypass Display Zones Bypassed will not ap pear In addition functions that are intended for use by the installer or servicer will not be displayed Note Functions may be manually scrolled forward or back...

Страница 18: ...e s Use NEXT E and PRIOR F to scroll fire troubles Activate Overview OPTIONAL For GEM P9600 3200 panels only Overview programmed for user YES NO In a partitioned system this mode displays the status o...

Страница 19: ...ror codes Start Exit Time OPTIONAL Start Exit Time programmed YES NO In Com mercial Burglary systems exit delay may have been programmed to start after a central station ringback verification signal h...

Страница 20: ...nd the key pad will begin a 15 minute countdown with the sounder pulsing During this time arm ing may be delayed an additional 1 to 4 hours as above or autoarming may be can celled by arming and disar...

Страница 21: ...as a battery that is weak and requires replacement A display of Z01TAM tamper condition indicates that the case of the transmitter on Zone 1 is open A display of Z01SUP supervisory failure indicates t...

Страница 22: ...to 45 sec onds at your option by consulting with your installer Regular Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report...

Страница 23: ...nds a communication problem may exist call for service The Start Exit Time function may then be used to manually start the exit delay however reporting capability may be sacrificed If your system does...

Страница 24: ...24 NOTES...

Страница 25: ...blue G button 6 The programmed code or description will not be permanently stored until you press D 7 To exit the Program Mode press C Programming User Codes Do not attempt to program a code contain i...

Страница 26: ...Press D to save the code in mem ory Repeat steps 3 6 for each user Note Duplicate Codes are not allowed therefore a duplicate Code entered in the LCD Window will erase when D is pressed Note To void...

Страница 27: ...Press J to save the code 6 Press C to exit the Program Mode Notes Note Duplicate Codes are not allowed therefore a dupli cate Code entered in the LCD Window will erase when D is pressed If the system...

Страница 28: ...es that Chime or Watch Mode is on Note If Watch Mode is programmed MONITOR ON will not dis play for Chime Mode Panel reporting to central station on arming If necessary wait for ringback signal before...

Страница 29: ...ode Arming attempted with a system trouble present To arm press C and the sys tem troubles will disappear The alarm signal has been cancelled during the Abort Delay before an alarm signal report was s...

Страница 30: ...Bypassed Dsp Bypass displayed indicates zone s that have been de activated where XX represents the zone number s OPTIONAL For partitioned systems only Code not valid for area For Commercial Systems O...

Страница 31: ...checked in E05 01 Transmitter on Zone 1 has a low battery E15 01 Transmitter on Zone 1 has its case open tamper condition OPTIONAL Commercial Systems Only Overview Mode Simultaneously shows status of...

Страница 32: ...ing the system on off by entering your code at the keypad then pressing J Battery Backup power source in the control panel enclosure to provide protection in the event of a power failure BYPASS Button...

Страница 33: ...em that has been subdivided into two or more up to eight independent subsystems areas Pre Alarm Warning A keypad sounder alert of an impending alarm This option is programmable by zone for the same du...

Страница 34: ...d entry delay for interior devices Entry delay only occurs if re entry takes place through the normal exit entry door first Fire Zone Detects fire alarms or trouble conditions Interior Zones Circuits...

Страница 35: ...NN Keypad Response Failure NN Keypad Number E11 NN Keypad Tamper Condition NN Keypad Number E12 NN Expansion Zone Module Re sponse Failure NN Module Number E13 NN Expansion Zone Module Tam per Conditi...

Страница 36: ...any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system ma...

Отзывы: