6
4. Each ACM door can detect three possible events:
Zone
,
Forced Entry
, and
Door Ajar
.
a) "
Zone
" – normal opening of the door.
b) "
Forced Entry
" – forceful opening of the door without unlocking it first.
c) "
Door Ajar
" - the door is opened and remains open (not closed) for more then 30 seconds.
Each of these events can be mapped to a separate zone on the GEM-X255 control panel. When the
door event occurs, the associated GEM-X255 zone will be tripped.
5. When
Arm All Areas Allowed
and
Disarm All Areas Allowed
are selected, simultaneous arming
and disarming of multiple Areas from a selected reader will be allowed. Note that Arming/Disarming is
only allowed from ACM's Reader #1. A user attempting to Arm/Disarm multiple areas must have their
proximity card enabled in those areas and must have arming and disarming privileges.
For example, in the image above, multiple arming can be accomplished from the ACM#1 Reader #1
and multiple disarming can be accomplished from ACM# 1 Reader #1 and ACM #2 Reader #1.