NAPCO F-TPBR Скачать руководство пользователя страница 4

4

 

TOUCHPAD PIR 

 

The F-TPBR TOUCHPAD includes an integral PIR sensor 
which provides the following system functions: 

 

Activity Sensor 

The PIR is always gathering activity information which pro-
vides the system with data that is used to insure proper use of 
the system and prevent user errors.  For example, if the user 
arms AWAY and the F-TPBR TOUCHPAD senses movement 
in the room within 1 minute after arming AWAY, the system 
will automatically default to STAY mode arming, preventing a 
false alarm.  If additional PIR sensors are installed, the activ-
ity of these sensors will also be included in these decision 
making processes.     

 

Intrusion Protection Device 

When the system is armed AWAY, the PIR provides intrusion 
protection with a range of 25’ at a 90° pattern of protection.  
An intruder detected in this protected area will cause a Zone 8 
alarm with a corresponding central station report and audible 
alarm.  

NOTE:  

If Touchpad PIR Intrusion Protection is not 

desired, it may be disabled by installing configuration jumper 
JP1.2. 
 

Pet Protection 

The F-TPBR Touchpad is provided with a Pet Alley Lens in-
stalled, creating a low-sensitivity zone close to the ground that 
will not detect pets under 24” in height.  

Note:  

For installa-

tions with pets, additional perimeter and/or interior protection 
may be required to ensure system integrity. 
 

Protection Pattern

 

The diagrams at right illustrate the Pet Alley pattern of protec-
tion.  The 

Side View 

pattern of protection illustrated reflects 

an F-TPBR Touchpad installation height of 5 feet.   
 

IMPORTANT:

  If the F-TPBR TOUCHPAD can be accessed 

from an area that is not protected by the pattern of protection 
provided by the Touchpad PIR, then additional protection is 
required.  This may include protecting other doors and win-
dows or additional space protection. 

25’ 

90º 

5º 

Anti-Tamper Beams

 

Intrusion Protection 
Beams

 

Top 

View 

5’ 

25’ 

5’ 

10’ 

15’ 

20’ 

 

Side View 

Содержание F-TPBR

Страница 1: ...n the AWAY mode During an entry delay or an alarm the system may only be disarmed and si lenced by inserting the F IFOB digital key into the F IFOB slot on the F TPBR Touchpad or F TP Touchpad By allo...

Страница 2: ...Wire the F TPBR Touchpad to the F 8 Panel as shown on wiring diagram Terminal 1 is 12 V DC Term 2 is GND and Term 3 is Data Terminal 4 Alarm Output The F TPBR Touchpad has an integral sounder but unli...

Страница 3: ...ttom into place 6 Seal access holes IMPORTANT After creating your service loop of wires seal the access holes with putty supplied to ensure F TPBR Touchpad is air tight This important step is nec essa...

Страница 4: ...m with a corresponding central station report and audible alarm NOTE If Touchpad PIR Intrusion Protection is not desired it may be disabled by installing configuration jumper JP1 2 Pet Protection The...

Страница 5: ...o secure the plug 7 Plug Receptacle Wires Be certain retainer latch secures plug PC Board In the center of the PC board is a speaker with black and red wires connected to a plug mated to a receptacle...

Страница 6: ...Touchpad Face Double check all connections to the F TPBR Touchpad using the wiring diagram as a guide Be sure all ac cess holes are sealed with putty to ensure F TPBR Touchpad is air tight Snap the f...

Страница 7: ...TRANSFORMER TRF12 OR QUIVALENT SEE WI1431 Class 2 Transformer DO NOT connect to switched outlet 1 2 3 4 5 6 7 8 12 13 14 15 16 17 18 19 FIRE BELL GND GREEN BLACK RED 2 WIRE SMOKE DETECTORS RED BLACK G...

Страница 8: ...8 MOUNTING TEMPLATE 6 1 4 TOP UP 2 0 3 5 2 3 8 4 3 8 3 5 16 Wire Access Hole Cut in Wall SINGLE GANG MOUNTING HOLES...

Отзывы: