3
Installing the Freedom F-TPBR Touchpad
Care should be taken to select a mounting area that provides a proper field of view for the PIR sensor. See page 4
for more information. The following instructions illustrate the steps required for installation of the F-TPBR Touchpad.
Make Connections and
Create Service Loop
Punch holes with an awl in
the F-TPBR Touchpad base fit-
ting the wire sizes used and pull
wires through base. Secure
base to wall. Wire to F-TPBR
Touchpad using wiring diagram
as a guide.
Push all excess wire back into
wall leaving a short loop (about
3”-4”) of slack wires for service
purposes.
4
Install the F-TPBR Touchpad
Face
Double-check all connections to the F-
TPBR Touchpad using the wiring dia-
gram as a guide. Snap the front of the
F-TPBR Touchpad onto the base by
first inserting the 2 slots in the top onto
the corresponding tabs on the base
and then snapping the bottom into
place.
6
Seal access holes--
IMPORTANT:
After creating your
service loop of wires, seal
the access holes with putty
(supplied) to ensure F-
TPBR Touchpad is air tight.
This important step is nec-
essary to prevent air drafts
from entering the F-TPBR
Touchpad from the wall
cavity.
5
Cut access hole
Install (4) wall anchors and
cut access hole in wall.
Pull 4 conductor bus wire from
F-8 Panel into opening.
Warning:
Use caution when cut-
ting holes. There may be high
voltage wiring in wall.
3
Mark the holes
. Mount any-
where in a room with a favor-
able PIR field of view, ap-
proximately 60" high (measured
from the floor to the top of the F-
TPBR Touchpad).
Affix the template to the wall and
mark or punch through the 4 oval
mounting holes and the wire ac-
cess opening
.
2
60”
Ç
TOP UP
Open the F-TPBR
Touchpad
. Remove
the front of the F-
TPBR Touchpad housing
by inserting a screw-
driver into the (2) slots in
the bottom of pad.
Push the screwdriver up
and gently twist to un-
hook the plastic tabs
which secure the face of
the F-TPBR Touchpad to
its base.
1
Access
Hole
Wall
anchors
(4)
Push tabs up
and twist