NAPCO Continental Access SUPER TWO CICP1300IOCOMBO Скачать руководство пользователя страница 25

25                                 

Supervised Alarm / Relay / Power Expansion Unit

 

 
Ordering 

Orders for Continental products may be placed by 
calling Continental’s order department or by issuing a 
purchase order specifying the quantity of Products, the 
desired delivery date, shipping method, and the loca-
tion to which product should be shipped.  If an order is 
placed by telephone, it must be confirmed in writing 
by fax or mail. 
If the customer requests a guaranteed ship date or ex-
pedited shipping, Continental reserves the right to add 
to the price, with the customer’s approval, expenses 
which increase the cost of production and delivery, i.e. 
freight charges, overtime expenses, etc.  Continental 
reserves the right to change any price on this price list 
and all prices are subject to factory reconfirmation at 
the time of placing an order. 
 

Sales Assistance 

Continental will furnish to customers, reasonable 
quantities of product-related catalogs and other sales 
and promotional literature. 
Continental will provide customer training, both tech-
nical and sales at Continentals facilities in New York.  
Contact the factory for costs and requirements. 
 

Payment Terms 

Sales terms are Cash on Delivery (COD) unless 
prior credit arrangements are established. 

If credit arrangements are established with Conti-
nental, terms of sale are net 10 days. 

Interest charges shall accrue on all past due ac-
counts at a rate of 1.5% per month (18% APR). 

Continental reserves the right to place a customer 
on a C.O.D. status in the event that customer’s ac-
count becomes delinquent or Continental becomes 
unsure about customer’s financial capabilities. 

Continental will charge a Service Fee of $50.00 
for any returned check. 

If customer believes an invoice to be in error, cus-
tomer shall notify Continental of the error within 
thirty (30) days. 

Continental reserves a security interest in all prod-
ucts sold hereunder, together with all proceeds 
thereof to secure the performance of the cus-
tomer’s obligations hereunder. 

All orders unless otherwise requested are shipped 
F.O.B. Amityville, NY. 

 

Cancelled Orders 

Special or custom order items that cannot be cancelled 
with our suppliers are subject to a 100% cancellation 
charge. 
No unauthorized, returned merchandise will be ac-
cepted for credit. 
Orders returned or canceled are subject to a 25% re-
stocking charge. 
 

Return Material Authorizations 

No products will be accepted for return to Continental 
without prior written authorization (RMA).  Unauthor-
ized returns will not be accepted from the carrier by 
the receiving department.  The customer may request 
a return material authorization (RMA), whether for 
credit or repair of the product.  Continental will either 
issue an RMA or provide the customer with a written 
explanation for not issuing the RMA.  Except for war-
ranty claims, no returns will be accepted more than 60 
days after shipment from Continental.  Orders that are 
accepted for return are subject to a 25% restocking 
charge.  No product will be accepted for return which 
has been special ordered or custom in nature. 
 

Limited Warranty 

Return Material Authorization (RMA) numbers are 
required to be issued by Continental prior to returning 
any Product for service, repair, credit or exchange.  
Continental warrants that its Products shall be free 
from defects in materials and workmanship for a pe-

WARRANTY / TERMS & CONDITIONS 

Standard Terms of Sale 

Содержание Continental Access SUPER TWO CICP1300IOCOMBO

Страница 1: ...Supervised Alarm Relay Expansion Unit With Battery Backed Accessory Power Model CICP1300IOCOMBO Installation and Service Manual A NAPCO SECURITY GROUP COMPANY 355 Bayview Avenue Amityville NY 11701 Ph...

Страница 2: ...DISCLAIMER Continental Instruments LLC makes no representations or warranties with respect to the contents hereof and specifically dis claims any implied warranties of merchantability or fitness for a...

Страница 3: ...its for a Class A computing device pursuant to Part 15 of FCC Rules which are de signed to provide reasonable protection against such interference when operated in a commer cial environment Operation...

Страница 4: ...s 14 Grounding Accessory Drain and Shield Wires 14 POWER CONNECTIONS 15 AC Power Source Grounding 15 Modular Cable 16 ACCESSORY POWER 17 RELAY POWER 17 RELAY CONNECTIONS 18 Relay Characteristics 18 AL...

Страница 5: ...oximately four hours The Alarm Monitoring functions of the Alarm Relay Board are powered by the Access Control Panel and continue as long as the Access Control Panel is ac tive The Expansion Enclosure...

Страница 6: ...g Jurisdiction require Plenum Rated cabling UL Type CL2P cabling will be acceptable In Canadian installations CSA CMG FT4 foil shielded cabling may be used in non plenum installations and CSA CMP FT6...

Страница 7: ...Jack on the left side of the Super Two Access Control Panel Component Layout is shown below CONFIGURATION Figure 1 Expansion Unit Components Cable Tie Mounts Drain Wire Stud 12 Volt Power Supply AC P...

Страница 8: ...indicate a change in any Alarm Input status OK Flashes steadily to indicate a working connec tion to the control panel RELAY Indicates working power connection via 12V IN LOGIC Working 5 volt power f...

Страница 9: ...Board and the alarm inputs of the Super Two Access Control Panel AC power failure is signaled when AC power is lost or when this supervision circuit is opened 12V OK This output provides 12 VDC power...

Страница 10: ...cess Control Panel but be mindful of the 500mA load that must be met by the 12 Volt power source for each Alarm Relay Board Note The maximum total length of modular cable to be used to connect the thr...

Страница 11: ...dware the individual Card Reader electronics and wiring or the Electric Door Lock Hardware that will not be detected until the equipment is used For this reason please instruct staff at the installati...

Страница 12: ...0 inches wide 508mm X 4 0 inches deep 101 6mm Confirm that adequate free space exists on both sides of the Expansion Unit cabinet for cabling conduit entering and exiting the cabinet Determine the dir...

Страница 13: ...ce using the Expansion Unit cabinet as a template or using the measurements provided in Figure 6 NOTE Mark the small oval portion of the cabinet screw holes see Figure 7 Detail A and B below 3 Place t...

Страница 14: ...s See Important Safety Information page 6 Incoming Power Conduit Knockout The Expansion Unit requires the Mains Power Cable be con nected to the AC Input Terminal Block see page 15 The power cabling i...

Страница 15: ...res to the cable tie mount provided located below the AC Input Power Terminal Block NOTE Use of a dedicated unswitched AC power source results in optimal performance with minimum interference Table 1...

Страница 16: ...he first Alarm Relay Board must connect to the Access Con trol Panel using the Jack on the right side of the board A Pass through connector is on the left side of the board if addi tional boards are u...

Страница 17: ...of 1 60 Amps for Readers EM Locks and Accessories WARNING Observe Positive and Negative wire polarity be tween accessory devices and the Expansion Unit RELAY POWER The CICP1300IOCOMBO Expansion Unit...

Страница 18: ...ed near each relay will light when the associated relay is activated Metal oxide varistors MOVs are placed across the con tacts to reduce electrical noise The MOVs limit any noise caused by the switch...

Страница 19: ...tall the resistors close to the alarm contacts and embed them in epoxy Alarm Cable Requirements Connecting alarm sensors to the expansion board requires 22 AWG stranded shielded cables with drain wire...

Страница 20: ...eplace the fuse with a 1 ampere 1 00A 5x20mm slow blow UL approved fuse 4 Re install the fuse holder with the new fuse Expansion Unit Primary Fuse 230VAC Instal lations European Union A 1 2 ampere 0 5...

Страница 21: ...Replace the fuse with a 5x20mm 4 Amp 250V fast blow not a time lag fuse 5 Reset the main circuit breaker Expansion Unit Accessory Circuit Protection A 3 0 Amp resetable fuse protects the battery char...

Страница 22: ...ight of the board When being installed in the CICP1300IOCOMBO with the power supply and battery connect the small white Molex Connector from the cable plugged into RLY PWR OUT Connector When installed...

Страница 23: ...upply from the Expansion Unit cabi net 6 Install the new power supply in the reverse order of the removal Backup Battery Replacement WARNING Verify that the AC source voltage is switched off at the br...

Страница 24: ...D Temperature Range Operating Storage 32 115 F 0 46 C 32 149 F 0 65 C Relative Humidity 0 to 85 non condensing Link Programs 64 Standard POWER RATINGS As supplied from the factory the CICP1300IOCOMBO...

Страница 25: ...s financial capabilities Continental will charge a Service Fee of 50 00 for any returned check If customer believes an invoice to be in error cus tomer shall notify Continental of the error within th...

Страница 26: ...any indirect consequential or incidental damages in cluding those to person and those for lost wages or other economic loss Product Liability Continental s sole Liability and the customer s exclu siv...

Страница 27: ...30 34 31 35 32 36 33 37 34 38 35 39 36 40 Expansion Board 2 Relay Input 37 41 38 42 39 43 40 44 41 45 42 46 43 47 44 48 45 49 46 50 47 51 48 52 49 53 50 54 51 55 52 56 Expansion Board 3 VIRTUAL INPUT...

Страница 28: ...CATEGORIES 14 CHARGER PCB 5 CICP1300IOBD INSTALLING 22 COMMUNICATION CABLES 14 COMPONENT LAYOUT DIAGRAM 7 CONFIGURATION 7 CONFIGURATIONS ADDITIONAL 10 CURRENT DRAW SPECIFICATIONS 24 DISCONNECT THE BAT...

Страница 29: ...POWER 17 RLY PWR OUT 9 HEADER 17 SAFETY INFORMATION 6 SCHEMATIC 31 SECOND ALARM RELAY BOARD 10 SECOND SUPERVISED ALARM RELAY BOARD INSTALLING 22 SERIAL SIGNAL 8 SOFTWARE VERSION REQUIREMENTS 5 SPECIFI...

Страница 30: ...Supervised Alarm Relay Power Expansion Unit 30 NOTES...

Страница 31: ...pervised Alarm Relay Power Expansion Unit WIRING DIAGRAM AC FUSE BLOCK European Union IEC60127 T 0 5AL North America UL 1A Slow Blo MAINS INSTALLATION WIRING TO BE CARRIED OUT BY QUALI FIED PERSONNEL...

Страница 32: ...Supervised Alarm Relay Power Expansion Unit 32 A NAPCO SECURITY GROUP COMPANY 355 Bayview Avenue Amityville NY 11701 Phone 631 842 9400 Fax 631 842 9135...

Отзывы: