Napa 90-515 Скачать руководство пользователя страница 5

 

5

 

 Battery % –

 The digital display shows 

an estimated charge percentage of the 

battery connected to the charger’s battery 

clamps.

 Voltage –

 The digital display shows 

the voltage at the charger battery clamps, 

in DC volts.

 BATTERY TYPE BUTTON 

Use this button to select the battery type.

NOTE:

 Batteries should be marked with 

their type. If charging a battery that is not 

marked, check the manual of the item 

that uses the battery. If the battery type is 

unknown, use the AGM setting.

 – Used in cars, trucks and motorcycles, 

these batteries have vent caps and 

are often marked “low maintenance” or 

“maintenance-free”. This type of battery is 

designed to deliver quick bursts of energy 

(such as starting engines) and has a greater 

plate count. The plates are thinner and have 

somewhat different material composition. 

Regular batteries should not be used for 

deep-cycle applications.

 – The Absorbed Glass Mat 

construction allows the electrolyte to be 

suspended in close proximity with the 

plate’s active material. In theory, this 

enhances both the discharge and recharge 

efficiency. The AGM batteries are a variant 

of Sealed VRLA (valve regulated lead-acid) 

batteries. Popular uses include high-

performance engine starting, power sports, 

deep-cycle, solar and storage batteries.

 – The electrolyte in a GEL cell has a 

silica additive that causes it to set up or 

stiffen. The recharge voltages on this type 

of cell are lower than those for other styles 

of lead-acid battery. This is probably the 

most sensitive cell in terms of adverse 

reactions to overvoltage charging. Gel 

batteries are best used in VERY DEEP 

cycle application and may last a bit longer 

in hot weather applications. If the wrong 

battery charger is used on a gel cell 

battery, poor performance and premature 

failure will result.

LED INDICATORS

 

CLAMPS REVERSED (red) LED 

flashing:

 The connections are reversed.

 

CHARGING (yellow/orange) LED lit: 

The charger is charging the battery.

  CHARGED/MAINTAINING (green) 

LED lit: 

The battery is fully charged and 

the charger is in maintain mode.

NOTE: 

See

 Operating Instructions 

for a 

complete description of the charger modes.

 RATE SELECTION BUTTON

Use this button to set the maximum 

charge rate. Press the button until the 

desired charge rate is selected.

   (3A Charge/Maintain) –

 For charging 

small batteries, such as those commonly 

used in garden tractors, snowmobiles and 

motorcycles. Also used to maintain fully 

charged large batteries.

 (15A Rapid Charge) –

 For charging 

automotive, marine and light truck batteries. 

Not intended for industrial applications.

11. OPERATING INSTRUCTIONS

WARNING:

 A spark near the battery may 

cause an explosion. 

IMPORTANT:

 Do not start the vehicle with 

the charger connected to the AC outlet, or 

it may damage the charger.

NOTE:

 This charger is equipped with 

an auto-start feature. Current will not be 

supplied to the battery clamps until a 

battery is properly connected. The clamps 

will not spark if touched together. 

CHARGING A BATTERY  

IN THE VEHICLE

1. 

Turn off all the vehicle’s accessories.

2. 

Keep the hood open.

3. 

Clean the battery terminals.

4. 

Place the charger on a dry, non-

flammable surface.

5. 

Lay the AC/DC cables away from any  

fan blades, belts, pulleys and other 

moving parts.

6. 

Connect the battery, following the 

precautions listed in sections 6 and 7.

7. 

Connect the charger to an  

electrical outlet.

8. 

Select the battery type and charge rate.

9. 

When charging is complete, 

disconnect the charger from the AC 

power, remove the clamps from the 

vehicle’s chassis, and then remove 

the clamp from the battery terminal.

CHARGING A BATTERY  

OUTSIDE OF THE VEHICLE

1. 

Place battery in a well-ventilated area.

2. 

Clean the battery terminals.

3. 

Connect the battery, following the 

precautions listed in sections 6 and 7.

4. 

Connect the charger to the  

electrical outlet.

5. 

Select the battery type and charge rate.

Содержание 90-515

Страница 1: ...xplica c mo utilizar el cargador de bater a de manera segura y confiable Por favor lea y siga las siguientes instrucciones y precauciones GARDER LE MANUEL D INSTRUCTION ET LISEZ LE AVANT CHAQUE UTILIS...

Страница 2: ...VE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow these in...

Страница 3: ...position and removing AC cord from electric outlet Never allow clips to touch each other 5 2 Attach clips to battery and chassis as indicated in sections 6 and 7 6 FOLLOW THESE STEPS WHEN BATTERY IS I...

Страница 4: ...improper connection can result in a risk of an electric shock or electrocution NOTE Pursuant to Canadian Regulations use of an adapter plug is not allowed in Canada Use of an adapter plug in the Unit...

Страница 5: ...ERSED red LED flashing The connections are reversed CHARGING yellow orange LED lit The charger is charging the battery CHARGED MAINTAINING green LED lit The battery is fully charged and the charger is...

Страница 6: ...re none have the battery checked or replaced MAINTAINING A BATTERY This charger maintains both 6 and 12 volt batteries keeping them at full charge NOTE The maintain mode technology allows you to safel...

Страница 7: ...by trying to charge a large battery or bank of batteries on too low of a current setting Try again with a higher current setting or have the battery checked or replaced F04 The connections to the bat...

Страница 8: ...ssful after 10 hours the charger will go into abort mode The display shows bAD bAt F02 Desulfation was unsuccessful after 10 hours The battery may be defective Have battery checked or replaced The dis...

Страница 9: ...used subjected to careless handling repaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including b...

Страница 10: ...e intentar llevar a cabo cualquier actividad de mantenimiento o limpieza El simple apagado de los controles no reducir este riesgo 1 11 ADVERTENCIA RIESGO DE GASES EXPLOSIVOS a RESULTA PELIGROSO TRABA...

Страница 11: ...la carga as tambi n como los ndices de carga recomendados 3 6 Determine la tensi n de la bater a al consultar el manual del usuario del veh culo y aseg rese de que el interruptor de selecci n de la t...

Страница 12: ...le aislado de bater a de 24 pulgadas 61 cm de largo con calibre 6 seg n el Calibre americano de cables AWG por sus siglas en ingl s al borne NEGATIVO NEG N de la bater a 7 3 Conecte el gancho POSITIVO...

Страница 13: ...tes al cargador Tensi n La pantalla digital muestra la tensi n en los ganchos de bater a pertenecientes al cargador en volts de CC BOT N DE TIPO DE BATER A Utilice este bot n para establecer el tipo d...

Страница 14: ...ra CARGA DE LA BATER A EN EL VEH CULO 1 Apague todos los accesorios del veh culo 2 Mantenga el cofre abierto 3 Limpie las terminales de la bater a 4 Coloque el cargador sobre una superficie seca y no...

Страница 15: ...mas con la bater a problemas el ctricos del veh culo conexiones equivocadas u otras condiciones que surgan podr as causar absorsi n de corriente excesiva De modo que ocasionalmente seguimiento de su b...

Страница 16: ...al intentar cargar una bater a grande o bater as en serie en un ajuste bajo de energ a Intente otra vez con un ajuste m s alto de corriente o verif que o reempl ce la bater a F04 Las conexiones a la b...

Страница 17: ...el cargador pasar al modo de anulada La pantalla muestra bAD bAt F02 La desulfataci n fall despu s de 10 horas La bater a podr a estar en malas condiciones Verif quela o reempl cela La pantalla muest...

Страница 18: ...o modificado por personas que nos sean el Fabricante o si esta unidad es revendida a trav s de un vendedor minorista no autorizado El Fabricante no realiza ninguna otra garant a incluidas a t tulo en...

Страница 19: ...LLER A PROXIMIT D UNE BATTERIE AU PLOMB LES BATTERIES PRODUISENT DES GAZ EXPLOSIFS EN SERVICE NORMAL IL EST AUSSI IMPORTANT DE TOUJOURS RELIRE LES INSTRUCTIONS AVANT D UTILISER LE CHARGEUR ET DE LES S...

Страница 20: ...de sortie nominale du chargeur 4 EMPLACEMENT DU CHARGEUR 4 1 Placez le chargeur aussi loin que possible de la batterie que les c bles CC le permettent 4 2 Ne jamais placer le chargeur directement sou...

Страница 21: ...our effectuer le dernier raccordement 7 6 Pour interrompre l alimentation du chargeur mettre les interrupteurs hors circuit retirer le cordon C A de la prise enlever la pince raccord e au ch ssis et e...

Страница 22: ...marqu s faible entretien ou sans entretien Ce type de batterie est con u pour rapidement offrir de l nergie par exemple le d marrage des moteurs et a une plus grande teneur en germes Les plaques sont...

Страница 23: ...et taux de charge 6 Lorsque la batterie est charg e d brancher le chargeur de l lectricit d branchez la pince n gative et enfin la pince positive 7 Une batterie marine bateau doit tre retir e et char...

Страница 24: ...8 ou plus Charg 6 1 6 3 12 2 12 7 Doit tre recharg e Moins de 6 1 Moins de 12 2 D charg D LAI DE MARCHE Si aucune touche n est touch e dans les 10 minutes apr s le chargeur de batterie est mis sous te...

Страница 25: ...as de charges sur la batterie S il y en a enlevez les S il n y en n a pas faites v rifier ou remplacer la batterie bAd bAT F06 Le chargeur a d tect que la batterie peut tre devenir trop chaud emballem...

Страница 26: ...uvaise faites la v rifier ou remplacer L cran affiche bAD bAt F05 Le manque de progr s est d tect apr s que 12 heures au mode maintien se soient coul es La batterie ne tient pas la charge Cela pourrai...

Страница 27: ...ne r paration ou une modification par une personne autre que le fabricant ou si cet appareil est revendu au travers d un d taillant non autoris Le Fabricant ne fait aucune autre garantie y compris mai...

Отзывы: