![Nanomotion XCDX Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/nanomotion/xcdx/xcdx_user-manual_705065050.webp)
XCDX458000-00 rev A
50
Special Operations
implemented in vectors oriented along either X or Y axis. The following state
diagram describes Raster operation:
Figure 4: Raster Operation Flow Chart
To initiate Raster operation, first send to XCDX Raster Data command. In case
of non-rectangular raster, the Raster Data command must be followed with a
set of Add Vectors commands to specify individual vectors. To start physical
operation, send Raster Mode command with parameter 1 (Run).
Executing Raster operation can be interrupted by sending Raster Mode
command with parameter 2 (Pause) or 4 (Abort). In case of Pause, the
operation stops after finishing the current vector and waits for the next
command. Usually, the next command is Raster Mode with parameter 3
(Resume) that continues execution from the next vector. In case of Abort, the
operation stops immediately after decelerating current motion to zero velocity.
4.6.2
R
ASTER
D
ATA
Raster Data command should be sent before raster operation to initialize
internal data.
The Raster data command defines the following parameters