![Nanomotion XCDX Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/nanomotion/xcdx/xcdx_user-manual_705065046.webp)
XCDX458000-00 rev A
46
XCDX Commands
• T (optional): defines T value. If omitted, T is set to zero in the current
point.
4.5.13
K
ILL
Kill motion. The command causes deceleration of the axis at KDEC in all
axes or in the specified axes.
Selector (optional) - a bitwise mask that defines which coordinates are
involved (bit 0 - X, bit 1 - Y, bit 2 - Z, bit 3 - T). If the parameter is
omitted, all axes assumed.
4.5.14
S
ET
T
RIGGER
P
OLARITY
Set trigger polarity.
The parameter defines polarity of the trigger pulse:
• 0 - active low
• 1 - active high
4.5.15
J
OYSTICK
Enable / disable joystick operation. If joystick is enabled, three analog
signals from 3D joystick are transformed into X/Y/Z velocity. If joystick is
disabled, the signals are ignored.
• Selector: a bitwise mask that defines which coordinates are involved
(bit 0 - X, bit 1 - Y, bit 2 - Z).
Command ID
Parameters
Format
103
Selector (opt)
X (opt)
Y (opt)
Z (opt)
T (opt)
Int8(1)
Real(4)
Real(4)
Real (4)
Real (4)
Command ID
Parameters
Format
105
Selector
(opt)
Int8 (1)
Command ID
Parameters
Format
106 Polarity
Int8