![Nanomotion AB1A-3U Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/nanomotion/ab1a-3u/ab1a-3u_user-manual_705064021.webp)
Connections and I/O Settings
Nanomotion Ltd.
Page 21 of 29
2.5
Fault Output
Fault: An open collector logic output that is active shorted to ground under the
following conditions:
•
Over Current
•
The motor is not connected and the “Motor Disconnect” signal
is floating
•
Emergency Stop
NOTE:
The Fault output is capable of sinking a maximum of 20 mA, and is not
protected from over current.
2.6
LED Indicators
There are five LED indicators located on the front side of the card. See Figure 8 for
LEDs’ locations.
•
Power ON
. Green LED. Lights when 48V is applied
•
Fault
. Red LED. Lights when over current protection is
triggered.
•
Motor Disabled
. Red LED. Lights when motor is connected
and the driver is disabled.
•
Motor Not Connected (NC)
. Red LED. Lights when motor is
not connected.
•
Motor Enabled
. Green LED. Lights when drive is enabled.