Connections and I/O Settings
Nanomotion Ltd.
Page 16 of 29
Connect the following groups of cables together, isolating each of the signals:
•
POWER SUPPLIES – use 22 AWG (or lower AWG) wires for
the power supplies. For noisy surroundings, it is
recommended to twist the ground line and the power line
together.
•
ANALOG COMMAND – a twisted shielded cable is
recommended.
•
DISCRETE INPUTS – These signals are not sensitive to
noise and can be grouped together in the same harness with
any of the other groups.
2.2.1 Shielding
As the high motor voltage is induced on the cable shield, it is required to ground the
shield on both motor and driver sides to the infrastructure earth.