background image

11111111 )�  PLEASE READ THESE INSTRUCTIONS

11111111  '/ 

FIRST BEFORE INSTALLATION 

Congratulations on the purchase of your new Nanolux CMH-315NC fixture 
We have done everything to insure a long life and safe operations,  but the 
installations and use of the ballast is the responsibility of the user.  Incorrect 
use or installations can lead to failure and damage to the ballast.  Damage 
to  the  luminaire  and  electronic  circuitry  as  a  result  of  incorrect 
installations and use revokes your warranty. Read  this manual  carefully 

before installing your luminaire. 

CD 

TECHNICAL SPECIFICATIONS

Model 

Input Voltage 

Output Voltage 

Input Frequency 

Output Power 

Power Factor 

Crest Factor 

THD 

Dimming 

Strike lamp 

Protection 

Function 

Size 

(l*W*H) 

Weight 

CMH 315NC 

No Fan 

120VAC,240VAC,27NAC(Optional) 

80VAC-1S0VAC 

50Hz-60Hz 

315W Max 

�0.99 

,;1.7 

;;10% 

none 

CMH 315W 

Over Temperature;Over/Under Voltage;Open/Short Circuit 

554*420*243mm(21.8*16.5*9.6 inch) 

6.0kgs(13.21bs) 

� INSTALL FIXTURE ON BALLAST 

1. Make sure power is off!!! 

2. Insert the fast mounting clips into the cutout in the center of the ballast, 

and slide them off to opposite sides. 

3. Hold the fixture from its base and plug in the fixture bu inserting terminal 

into the socket. 

4. Slide the fast mounting clips into the grooves on the ballast until they are 

in place to hold the fixture. 

5. Press the fast mounting lever to lock in place. 
6. Confirm the fixture is installed on the ballast properly and is not loose. 

1) Place  the  reflector over the  three bolts on the  mounting frame of 

the  ballast. Align  the  hood so  that  the  pin  alignment hole on the 

hood is in the same quadrant  as the alignment hole on the ballast 
frame. 

2) Rotate the hood clockwise so  the hood is aligned squarely with

the ballast assembly.

-01-

Adjust the reflector to

secure the pin into 

the hole. 

·�o�• 

[� 

SCOPE OF USE 

The Nanolux  CMH-315NC  fixtures  are  designed  to drive horticultural 
ceramic  metal-halide  lamps  for plant cultivation. They are  intended  for 
climate  room use. They are suited  for damp  locations but should not 

be used  outdoors or in wet environments. 

High Intensity Discharge lamps generate intense heat. Installations of HID 
lamps should follow local installation and safety regulations. 

1••�f 

INSTALLATION COMPLY WITH LOCAL

..-.  INSTALLATION REGULATIONS 

These  luminaires  are  suitable  for  a  damp  indoor  location.  Do  not  install 
your luminaires in a wet environment or outdoors. 

Do not operate these luminaires close to combustible materials. The lamp 
and reflector will get hot during operation.  Do not touch the reflector or 
lamp during or right after operation. Make  sure the power cord does not 
touch  any  hot  part  of  the  luminaire.  Make  sure  the  lamp  is  clean  and 
inserted correctly. 

A  normal  operating  environment  temperature  should  be  below  122

°

F. 

Exceeding the maximum environmental temperature will stress electronic 
components, which will lead to shorter lifetime and decreased reliability. 

When using a NCCS RTU in the USB port of a Nanolux ballast, the Dimming 
function control dial on the ballast will be taken out of function. 

-02-

RTU is removed from the ballast during operation OR the RTU loses comm­

unication with the DTU for any reason, the ballast will automatically turn off 

after 10 minutes. The ballast has to be unplugged from the power source and 
turned back on to reset. The ballast will then run in regular mode (no  NCCS) 
or if a RTU is plugged in, it will operate in NCCS mode. If the ballast continues 

to turn off for any reason during operation with the RTU in NCCS mode, replace 
the RTU and confirm it is communicating with the DTU. 
For further NCCS APP customer support and tech support pages, visit 

www.nanoluxtech.com. 

LAMP REPLACEMENT  AND HOT 

RESTRIKE 

CA UTION: 

00 0 

& && 

• Always install the lamp before connecting your luminaire to mains. 
• Allow lamp to cool 30 minutes before restarting (hot restrike). 
• When changing the lamp always disconnect the luminaire from mains 

by removing the mains plug. Let the lamp and reflector cool down for 

30  minutes  before  changing as they are very hot. When replacing a 

defective lamp without disconnecting the mains,  the lamp  will  not 
start. Disconnecting the power and reconnecting it will restart theballast. 

TO TAKE OUT A LAMP: 

• DISCONNECT THE MAINS  FIRST
• The  base  has  two  prongs  that  are  twisted  counter-clockwise  then 

pulled outward. It is recommended to handle and  hold the lamp by its 
base in order to prevent breaking the lamp. 

TO INSTALL A NEW LAMP: 

• DISCONNECT FROM MAINS FIRST 
• Make sure the lamp is clean, wear cotton gloves and clean the lamp 

after installation with a dry soft cloth. Never use detergents to clean 
a lamp, use pure alcohol  or wipe clean with a dry  clean soft cloth.

• Hold the lamp from its base and align the terminals to the sockets 
• Hold  the  lamp  from  its  base  and  Plug  in  the  the  lamp  by  inserting 

both terminla in the socket and press together firmly. 

• Turn the lamp in a clockwise to lock in place (or lock) 
• Wipe the lamp with a clean soft cloth. 
• Be sure not to touch the reflective material of the reflector with your 

bare hands. 