9
heatless desiccant air dryer
D2
2.4 typical system layout
IMPORTANT:
It is essential that the system into which the unit is installed is fitted with a pressure limiting/
relief device. This device should be installed between the compressor and the unit.
IMPORTANT: Inlet valves have a single direction flow. Any reverse flow of these valves can cause irreparable
damage to the valve diaphragms.
By-pass
(optional)
Recommended
inlet filtration
0.01 μm filter
1 μm filter
water separator
inlet flow
compressed
air outlet
compressed
air inlet
outlet flow
2.5 site location
When selecting an installation site for the unit, ensure the following conditions are met:
•
Installation site should be located indoors on a flat protected from the weather and other harmful conditions.
•
The ambient temperature must not drop below 1.5°C (34.7°F) or exceed 50°C (122°F)
•
The installation site should be level and able to support the weight of the product.
•
Ensure sufficient space around the product, to allow access for operation and maintenance.