6
heatless desiccant air dryer
D2
2.
technical specification
specifications
standard
options
maximum water content (ISO class)
class 2 -40°C (-40°F) pdp
class 1: -
70°C (-94°F) pdp
minimum operating pressure
4
barg (
5
8 psig)
-
maximum operating pressure
16
barg (
232
psig)
-
recommended operating temp range
1.5 to °
C (35 to
°
F)
-
design operating temperature range
1.5 to 50°
C (35 to 122
°
F)
-
power supply requirements
100-240V AC @ 50-60 Hz
24V DC
consult rating label, options operating parameters may differ
ISO Class 2 at recommended max rated flow at 7 Barg and 25°C inlet; see correction factors.
2.1
flow rates
model
inlet flow rate
connection
Nm3/hr
scfm
inlet
outlet
NDL-060
58
34.1
1”
BSPP or NPT
1”
BSPP or NPT
NDL-070
70
41.2
NDL-080
90
52.9
NDL-090
112
65.9
NDL-100
150
88.2
NDL-110
180
105.9
NDL-120
224
131.8
NDL-130
301
177.1
Inlet Tempertrue Correction Factors
°C
5
10
15
20
25
30
35
40
45
50
°F
41
50
59
68
77
86
95
104
113
122
correction factor
0.8
0.9
0.94
1
1
0.98
0.95
0.9
0.85
0.72
Inlet Pressure Correction Factors
barg
4
5
6
7
8
9
10
11
12
13
14
16
psig
58
72
87
101
116
130
145
159
188
203
217
232
correction factor
0.63
0.75
0.88
1
1.13
1.25
1.38
1.50
1.63
1.75
1.88
2.13
Содержание D2