2. Preview interface 
On Home Interface, user can enter into PREVIEW       interface, the interface will display some basic configurations, energy 
consumption, date, floor temperature etc. 

Short press button        to select the item you would like to modify, then short press up and 
down buttons to modify value of selected item, then short press button       to save and quit, 
short pressing button        only quits without saving.

Short press      button on Home Interface to switch operation modes: the icons of Away, Auto, Manual, Drying, Off modes  
will be displayed alternatively for 3 seconds and last displayed mode will be selected, or just short press 

F

 button to select 

a desired mode when the modes’ icon displayed alternatively. Press and hold       button on Home interface for over 3 
seconds to select Away mode directly, then Press and hold        button for 3 seconds to quit Away mode.

1.Away Mode:

 the device will control the heating system according to the set temperature within the set period.

User can set time to leave home and time to go home according to the requirements of themselves, and set how the 
device will control the temperature during this period.
1.1. If away mode has already been activated, the end time for away mode is valid, the device will execute Away Mode 
Temperature Schedule before the end time.
1.2. If away mode has already been activated, the values of end time for away mode are set as 0, the device will always 
execute current set temperature with no time limitation. The device will consider the mode as anti- freeze mode, the 
recommended temperature setting is 4-10°C.

2. Auto Mode:

 the device will control the heating system according to the configured time schedule or Z-Wave protocol 

Energy_Save_Heating Setpoint.
2.1. When configuration parameter 8 value set as 1, the device will control the temperature of energy save mode accord-
ing to the temperature set by Command Class Energy_Save_Heating Setpoint or set by using the move up and down 
buttons, following mentioned schedule will be invalid.
2.2. When configuration parameter 8 value set as 0, the temperature set by Command Class Energy_Save_Heating 
Setpoint and set by using the move up and move down buttons will both be invalid, Energy Save Mode will control 
temperature according to following user schedule.
For instance, if user would like to keep room temperature at 18C during 18:00-23:00 on every Monday, and keep room 
temperature at 20C after 22:30 on every Monday, then user can set schedule by himself.

Time Setting 

Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as follow:

Settings Menu

Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as follow:
Enter settings menu (needs to be added)
1. Under Home Interface, meanwhile the device is at OFF mode (Off icon), press and hold up and down buttons at the 
same time for over 5 seconds to enter Settings Menu.
2. Short press move up and down button to select a settings item, then short press button F to enter selected item.
3. Settings menu include, Preview menu, Z-Wave settings, Schedule, Monitor settings, Time/Date settings, Other settings

Control Mode

F

Содержание TOUCH Z-WAVE 16A

Страница 1: ...INSTRUCTION MANUAL NAMRON TERMOSTAT TOUCH Z WAVE 16A ...

Страница 2: ...eter can also be configured through advance config parameter 10 1 Away 2 Auto 3 Manual 4 Drying 5 Off Standard EN 60730 1 2016 A1 EN IEC 60730 2 9 2019 A1 EN IEC 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 60730 1 2016 A1 2019 EN 60730 2 19 2019 A1 2019 A2 2020 EN 50663 2017 ETSI EN 301 489 1V2 2 3 ETSI EN301 489 3V2 1 1 ETSI EN300 220 1 v3 1 1 ETSI EN300 220 2 V3 2 1 RED 2014 53 EU Certificate Z ...

Страница 3: ...o the connection box by tightening the screws Make sure that the thermostat is fixed without deformation Suggested torque is 0 2 0 4Nm 2 0 4 1kgf cm NTC L L N N L N Floor temp sensor SR ZV9092A 4512744 Off mode Manual mode Auto mode Drying mode Floor temperature Away mode Weekdays Time shift button Mode button Set temperature Function button Monitor set Other set Included to a Z Wave network Sched...

Страница 4: ...limitation The device will consider the mode as anti freeze mode the recommended temperature setting is 4 10 C 2 Auto Mode the device will control the heating system according to the configured time schedule or Z Wave protocol Energy_Save_Heating Setpoint 2 1 When configuration parameter 8 value set as 1 the device will control the temperature of energy save mode accord ing to the temperature set ...

Страница 5: ...d lasts After Mode set the mode after the drying mode ends Remain shows the remaining time of the drying mode For configuration method and modification please refer to Automatic Mode Energy Save Mode Schedule 5 Off Mode this mode only enables the device to turn on the heating system when anti freezing mode is enabled and the device meets all required conditions otherwise the device will not work m...

Страница 6: ...button for over 3 seconds or reset power of the device After cancel manually the relay will show heating forbidden icon within 120 seconds but other operations are allowed To prevent the undulation of sensor temperature when the sensor temperature is approaching the set temperature which will cause that the controller may keep switching on off the relay Here hysterersis enables the controller to c...

Страница 7: ...rough Advance Config parameter 11 and 12 Other Set Temperature Compensation Device state after reset power of the device If set as last status device will go to the status before power failure after power on again If set as default device will go to default mode after power on again This parameter can also be configured through Advance Config parameter 4 Re power Status To ensure the safety of the...

Страница 8: ...l be removed from the Z Wave network Select Reset then short press button the device will start reset Status will show Reset If there is no response from a gateway within 6 seconds or exclusion failed Status will show Fail If reset successfully Status will show Reset OK Note 1 if the device is excluded or reset successfully the Auto Mode Schedule will be reset to default value Note 2 the sent fram...

Страница 9: ..._Away_Heating set away temperature ThermostatSetPoint V2 COMMAND_CLASS_SECURITY V1 COMMAND_CLASS_SECURITY_2 V1 COMMAND_CLASS_TRANSPORT_SERVICE V2 COMMAND_CLASS_SUPERVISION V1 YES V3 YES V1 YES V2 YES V2 YES V3 YES V1 YES V3 YES V2 YES V1 YES V1 YES V1 YES V1 YES V8 YES V3 COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_OPERATING_STATE COMMAND_CLASS_THERMOSTAT_SETPOINT COMMAND_CLASS_ASSOCIAT...

Страница 10: ...CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO V2 V1 V1 V1 V5 YES YES V2 YES V3 YES V1 EndPoint2 floor temperature sensor command list Group ID Description 1 5 NAME Lifeline Profile Max nodes AGI_LIFE_LINE 0x0001 1 Send Command Class DEVICE_RESET_LOCALLY_NOTIFICATION to associated devices of this group when factory reset the device 2 Send Command Class THERMOSTAT_SETPOINT_REPOR...

Страница 11: ...evel 2 High Level 0x0A 10 1 1 Other Set Temperature control reference selection 1 room sensor 2 floor sensor 3 room floor sensor 0x04 4 1 1 Other Set Whether to recover to settings before power failure or power reset 0 use default settings 1 recover to settings before power failure or power reset 0x08 8 0 1 None Auto mode Energy save mode temperature schedule 0 use schedule set by user 1 use Energ...

Страница 12: ...ld unit is W 0 disable to report 1 100 report when absolute threshold is 1 100 0x13 19 10 1 None When to report current change absolute threshold unit is 0 1A 0 disable to report 1 10 report when absolute threshold is 1 10 0x14 20 2 1 None When to report voltage change absolute threshold unit is 1 V 0 disable to report 1 10 report when absolute threshold is 1 10 0x17 23 0 1 Other Set This paramete...

Страница 13: ...Namron AS Nedre kalbakkvei 88B 1081 Oslo Norway post namron com ...

Отзывы: