0x15(21)
600
(10mins)
4
None
Time interval value for periodic active report of Meter
60-2678400 (31 days) , unit is S
0x16(22)
1
1
Other Set
The OLED display brightness when operate the device.
0, low level
1, mid level
2, high level
0x11(17)
300
(5mins)
1
None
Time interval value for periodic report of temperature, humidity, unit is S
0, disable to report
30~28800, report when time interval value is 30~28800
0x12(18)
5
1
None
When to report power change absolute threshold, unit is W
0, disable to report
1~100, report when absolute threshold is 1~100
0x13(19)
10
1
None
When to report current change absolute threshold, unit is 0.1A
0, disable to report
1~10, report when absolute threshold is 1~10
0x14(20)
2
1
None
When to report voltage change absolute threshold, unit is 1 V
0, disable to report
1~10, report when absolute threshold is 1~10
0x17(23)
0
1
Other Set
This parameter defines which sensor temperature will be displayed on
Home page.
0x00: indoor a ir temperature
0x01: external temperature (floor temperature)
0x18(24)
0
1
Other Set
The time zone that the time parameters command adopts is UTC, the time
zone need to be set:
+12 ~ -12