23
8. Error Codes
If an error is generated, the roulette lamp flashes to indicate the type of the generated error.
When an error is generated, check the lamp flashing pattern to identify the type of the generated error, and
take the corrective measure indicated below.
If the following measures do not correct the problem or if you have any question regarding the game
machine, contact your distributor.
z
z
z
z
z
Before performing the maintenance, be sure to turn off the power switch of the machine
to prevent an electrical shock.
z
z
z
z
z
Use only specified parts when replacing consumables. Using improper parts can
result in a fire or equipment malfunctions.
z
z
z
z
z
Inspect the inside of the machine regularly, and remove any foreign items. Foreign
items can cause a fire or electrical shock.
z
z
z
z
z
If the machine generates an abnormality, turn off the machine immediately and contact
your distributor.
Operating the machine without correcting a problem can result in a fire or electrical
shock.
WARNING
Error indication
Type of error
Main symptom
Corrective measure and resetting method
Flashing of 2-point
lamp
Flashing of 5-point
lamp
Flashing of 10-point
lamp
Flashing of 50-point
lamp
Flashing of ?-point
lamp
Jammed coins
Tilt error
Jammed Goal switch
Mouse Open/Close
switch error
Hopper error
Coins are jammed.
The Tilt switch detected
shaking of the machine.
The Goal switch is not
operating properly.
The Mouse Open/Close
switch is not operating
properly.
There is no coin in the hopper.
Foreign items or incorrect-
size coins are jammed inside
the hopper.
Remove the jammed coins. When the jammed
coins are removed, the machine automatically
resets.
DIP switch A No. 6 ON
Press the Clear Error switch. The machine
resets after 10 seconds.
DIP switch A No. 6 OFF
The machine automatically resets after 10
seconds.
Remove the cause of the jamming, and press
the Clear Error switch to reset the machine.
Remove the cause of the jamming, and press
the Clear Error switch to reset the machine.
Fill the hopper with coins or remove foreign items
and incorrect-size coins from the hopper, and
then press the Hopper Test switch to reset the
machine.