Nalite Aquator Silver Скачать руководство пользователя страница 3

Two  appliance  modifications  are  manufactured:  modification  SILVER  is  used  for  production  of 

ionized  and  silvered  water,  and  modification  CLASSIC  is  used  for  production  of  ionized  water  only. 

Their technical data is presented in the table below. 

 
 
 

Title of parameters   

Values of parameters 

SILVER 

CLASSIC 

Container capacity, l 

Power supply voltage, V~ 

AC frequency, Hz 

Fuses, VP, A 

Average duration of electrolysis when generating: 

-  ionized water, min 

-  silvered water, sec 

Silver electrode weight (purity 999.9), g 

Power consumption when generating: 

-  ionized water, W 

-  silvered water, W 

Appliance total weight max., kg 

Operating conditions 

-  ambient temperature 

-  relative air humidity 

-  inlet temperature of water supply 

waterproof rating  

double and reinforced insulation  

it must not be disposed of with common 

household waste 

3.0 

110-230 

50 - 60 

 

9.7+/-0.1 

 

110 - 230 

1.2 

 

From 5 to 40

o

C  

From 80% to 25

o

C  

From 10 to 25

o

C  

IP54 

 

 

3.0 

110-230 

50 - 60 

 

 

110 - 230 

1.2 

 

From 5 to 40

o

C  

From 80 to 25

o

From 10 to 25

o

C  

IP54 

 

 

 
 

NOTE. Using the ionizer without adhering to the manufacturer's instructions may cause a safety risk. 

 

 

www.nalite.com

3.

 

TECHNICAL DATA

  

 

Содержание Aquator Silver

Страница 1: ...Pure water company presents www nalite com Nalite Natural Vitality Everyday...

Страница 2: ...has a slight positive electrical charge and acidic properties 7 2 pH 1 5 Partition membrane divides containers in two parts is conductive to the ions but prevents water from mixing 1 6 Silvered water...

Страница 3: ...ver electrode weight purity 999 9 g Power consumption when generating ionized water W silvered water W Appliance total weight max kg Operating conditions ambient temperature relative air humidity inle...

Страница 4: ...s recovery of natural acidic medium of the skin disinfection of premises and eco friendly agriculture Natural germicide Strong oxidizing agent Has an antiseptic anti allergic and contra inflammatory c...

Страница 5: ...ntainers 3 4 separated by membrane are fitted in the container 1 There are two marks on the inside of the container 1 the lower 5 indicates the minimum and upper 6 the maximum water level 5 3 The cove...

Страница 6: ...tion change Water leaking from the appliance containers during running or after the change of the membrane does not affect the quality of produced ionized water 5 6 Acidic water is generated at the an...

Страница 7: ...s are given relatively to calomel electrode Research report is stored in the enterprise Working time depend on salt content Appliance will let you choose pH values with 17 and 18 buttons by 0 2 unit W...

Страница 8: ...ues between 8 0 pH and 9 2 pH If the light electrode has been placed into the inner container select No by pressing the button 18 Then the appliance will let you choose from pH values between 9 0 pH a...

Страница 9: ...ot suitable for water ionizers as the emission of gases takes place in an acidic medium during the electrolytic Cl ions contained in the solution are soluble In this way metal from which the electrode...

Страница 10: ...t the silvered water into an opaque container 9 9 Clean the silver electrode 12 and the light electrode 7 carefully with a soft cloth If the electrodes are heavy contaminated clean them with a soft cl...

Страница 11: ...ntainer magnet is lost Close the cover rightly Insert the missing magnet 4 The message Silvered water is constantly displayed The inner container magnet is lost The magnetic sensor switch for the Silv...

Отзывы: