No. 

Breakdown signs 

Possible reason 

Solution 

1. 

The appliance does not switch on, 
the indicators do not light on, 
electrolysis is not running 

No power supply voltage 
Appliance is broken 

Check for power supply voltage  
Contact the manufacturer or its 
representative 

2. 

Ionization is weak: water of lower 
concentration is produced during the 
set time 

 Contaminated membrane 
 The light electrode is 
contaminated 

 Change the membrane. 
 Clean the electrode with vinegar 

3. 

The message ‘Cover is open ’ is 
constantly displayed 

The cover was closed 
wrongly 
The inner container 
magnet is lost 

Close the cover rightly 
 
Insert the missing magnet 
 

4. 

The message ‘Silvered water’ is 
constantly displayed 

The inner container 
magnet is lost 
The magnetic sensor 
switch for the ‘Silvered 
water’ is out of order 

Insert the missing magnet 
 
Contact the manufacturer or its 
representative 

 

 
12.1

 

The  warranties  are  valid  for  24  months  from  the  date  of  sale  if  the  user  has  not  violated  the 
requirements of this instruction.  

12.2

 

The  defective  appliance  has  to  be  delivered  to  the  store  where  it  was  purchased  or  to  the 
manufacturer during the warranty period.  

12.3

 

The  warranty  is  not  applied  if  the  appliance  is  damaged  mechanically  or  it  has  been  used  without 
adhering to the instructions. 

 

www.nalite.com

11.

 

TROUBLESHOOTING  

 12.

 

WARRANTIES 

Содержание Aquator Silver

Страница 1: ...Pure water company presents www nalite com Nalite Natural Vitality Everyday...

Страница 2: ...has a slight positive electrical charge and acidic properties 7 2 pH 1 5 Partition membrane divides containers in two parts is conductive to the ions but prevents water from mixing 1 6 Silvered water...

Страница 3: ...ver electrode weight purity 999 9 g Power consumption when generating ionized water W silvered water W Appliance total weight max kg Operating conditions ambient temperature relative air humidity inle...

Страница 4: ...s recovery of natural acidic medium of the skin disinfection of premises and eco friendly agriculture Natural germicide Strong oxidizing agent Has an antiseptic anti allergic and contra inflammatory c...

Страница 5: ...ntainers 3 4 separated by membrane are fitted in the container 1 There are two marks on the inside of the container 1 the lower 5 indicates the minimum and upper 6 the maximum water level 5 3 The cove...

Страница 6: ...tion change Water leaking from the appliance containers during running or after the change of the membrane does not affect the quality of produced ionized water 5 6 Acidic water is generated at the an...

Страница 7: ...s are given relatively to calomel electrode Research report is stored in the enterprise Working time depend on salt content Appliance will let you choose pH values with 17 and 18 buttons by 0 2 unit W...

Страница 8: ...ues between 8 0 pH and 9 2 pH If the light electrode has been placed into the inner container select No by pressing the button 18 Then the appliance will let you choose from pH values between 9 0 pH a...

Страница 9: ...ot suitable for water ionizers as the emission of gases takes place in an acidic medium during the electrolytic Cl ions contained in the solution are soluble In this way metal from which the electrode...

Страница 10: ...t the silvered water into an opaque container 9 9 Clean the silver electrode 12 and the light electrode 7 carefully with a soft cloth If the electrodes are heavy contaminated clean them with a soft cl...

Страница 11: ...ntainer magnet is lost Close the cover rightly Insert the missing magnet 4 The message Silvered water is constantly displayed The inner container magnet is lost The magnetic sensor switch for the Silv...

Отзывы: