NAL Research Corporation (TN2014-001-V1.4.5)
6
2.2 Iridium RF Specifications
Operating Frequency:
1616 to 1626.5 MHz
Duplexing Method:
TDD
Input/Output Impedance: 50
Multiplexing Method:
TDMA/FDMA
2.3 Iridium Radio Characteristics
Average Power during a Transmit Slot (Max):
1.6W
Receiver Sensitivity at 50
(Typical): –117 dBm
Maximum Cable Loss Permitted:
2dB
Link Margin – Downlink:
13dB
Link Margin – Uplink:
7dB
2.4 Electrical Specifications
Input Voltage Range:
+3.6VDC to +5.3VDC or +6.0VDC to +32VDC
Main Input Voltage Ripple:
< 40mV peak-to-peak
Transmit Current (Average):
200mA @ 5VDC
Transmit Current (Peak):
1.5A @ 5VDC
Receive Current (Average):
45mA @ 5VDC
Receive Current (Peak):
195mA @ 5VDC
Message Transfer Power (Average): <= 1.0W @ 5VDC
Current in Between Reports:
Less than 65
A @ 5VDC
Power Input Type:
DC power or LiIon battery
NOTE:
The DC power requirement was measured at the 9602-LP multi-interface connector
and not at the DC power supply. Users must take into account voltage drop across the power
supply cable to ensure adequate current provided to the 9602-LP during SBD sessions. If
input voltage does not stay above 3.0VDC during surge or high current demand, the 9602-
LP will reset itself.
NOTE:
The average current drawn during transmission may vary depending on the field-of-
view between the 9602-LP antenna and the Iridium satellite, the type of Iridium antenna
used and the cable loss.
2.5 Environmental Specifications
Operating Temperature Range: –40
o
F to +185
o
F (–40
o
C to +85
o
C)
Operating Humidity Range:
≤ 75% RH
Storage Temperature Range:
–40
o
F to +185
o
F (–40
o
C to +85
o
C)
Storage Humidity Range:
≤ 93% RH
NOTE:
Operating temperature range based on a duty-cycled usage model with the stand-
alone 9602 transceiver sending one SBD message per hour and is otherwise turned off during
the hour.