9
OPTION 1 -
Typical setup for most pools with automation
When using Option 1 the OXI will always be producing when unit is running so
you may prefer to reduce OXI output to stop chlorine levels increasing.
Did you know?
The Naked System is compatible with any external pool control system and will slave to
the controller allowing it to switch the unit ON and OFF. There are two options depending
upon the pool’s environment and use. If unsure, please contact us for further information.
Change Timers 1 and 2 in the Naked System to 00:00 to ensure the system is
always ON allowing it to be controlled completely by the external controller.
Change the unit from AUTO to ON using POWER MODE button on keypad.
STEP 1
STEP 2
OPTION 2 -
For indoor or very small pools
Timer 2 (T2) ON TIME must be adjusted to the same as T1 OFF TIME and T2 OFF
TIME must be adjusted to the same as T1 ON TIME. Resulting in the system
running in AUTO mode for 24 hours.
Did you know?
Note the timer settings from the Naked System (which were automatically
configured when the pool size was entered).
STEP 1
Enter Naked System timer settings into the timer settings of the external
controller to switch unit ON and OFF.
STEP 2
Example on a 50,000L Indoor Pool:
T1 ON TIME 08:00
T2 ON TIME 13:00
T1 OFF TIME 13:00. (Sanitisation)
T2 OFF TIME 08:00 (Filtration only)
The Ioniser will always switch off based on the volume of water entered so that
copper levels will not increase regardless of the Timers set.
There is a Water Flow Sensor in the OXI Cell. Please make sure the pump is
running whenever the Naked System is ON during Timers 1 and 2.
Did you know?
STARTUP | EXTERNAL CONTROLLERS