20/07/16 M26.1_Benzina Honda (Naked)_EN
ENGLISH
ENGLISH
REV
.0-07/16
M
26.1
Starting and Stopping
(Honda gX 200 / 270 / 390 gaSoLinE EnginE)
NOTE
Do not alter the primary conditions of regulation and do not
touch the sealed parts.
!
check daily
STARTING
1.
Turn the fuel cock (87) to ON
FUEL VALVE
2.
Switch the choke control (66) to CLOSE
N.B.
: Do not use the air valve if the motor is hot or the air
temperature is too high.
CHOKE LEVER
CLOSED
CLOSED
3.
Turn the engine switch (28) to the ON position
ENGINE SWITCH
STARTER GRIP
4.
Lightly pull the start-up knob (73) until meeting resistance,
then pull decisively
ENGINE SWITCH
FUEL VALVE
STOPPING
To stop the engine in an emergency, simply turn the engine
switch to the OFF position.
Under normal conditions, use the following procedure:
1) stop to draw single-phase current from the auxiliary sockets
2) Wait for a few minutes to allow the machine to cool off,
take however into consideration the prescriptions given in
the engine use manual
3) Turn the engine switch to the OFF position.
4) Shut the gasoline cock.
ATTENTION:
Allow the start-up knob to re-enter slowly, avoiding having it
knock against the motor and thereby damaging the start-up
system.
5.
Once the engine is started, with the starter off, let it turn for
a few minutes before drawing the load.
CAUTION
RUNNING-IN
During the first 50 hours of operation, do not use more than
60% of the maximum output power of the unit and check the
oil level frequently, in any case please stick to the rules given
in the engine use manual.
!
20