Nakayama SP1040 Скачать руководство пользователя страница 9

6

OPERATION

Connecting pressure pipe

- screw the pressure pipe onto the pressure connector. All joint 

connections must be sealed with a threaded sealing stripe.

-When using the hose, screw the right hose adapter into the 

pressure connector. 

-Secure the hose firmly to the hose adapter and secure it with a 

hose clamp. 

If it is used occasionally, please use a suitable pipe. A rigid pipe 

with a check valve is recommended for use in a fixed position. 

This can be done at the close of the machine to prevent liquid 

backflow.

Use a strong rope to connect the handle of the pump and dip it 

into the liquid to be conveyed at a certain angle, so that the 

lower side of the device has no bubble formation to prevent the 

bubbles from being sucked in. Put the equipment down slowly, 

and once the pump is submerged, it can be adjusted again. The 

pump is arranged at the bottom of a liquid container, Fasten the 

end of the rope after lowering so that the pump can also be 

handled when hanging on the rope. The pump can work after 

the device is connected to the main power source.  

The pump is not allowed to transport corrosive 

substances, flammable and explosive substances 

(such as gasoline, petroleum, nitro diluent), grease, 

oil, brine and toilet equipment sewage, as well as 

low mobility mud sewage. The temperature of the 

liquid cannot exceed 35 

°C

Содержание SP1040

Страница 1: ...www NakayamaTools com SP1040...

Страница 2: ...www NakayamaTools com RCCB 30m A 16...

Страница 3: ...www NakayamaTools com 350 60 60 cm 1 2 3 4 5 6 1 1...

Страница 4: ...www NakayamaTools com 2 2 1 2 1 2 1 2 1 2 1 2 1 2 350 C SP1040 230 V 50 Hz 1000 W IPX8 40 m 6500 l h 7 m 1 mm...

Страница 5: ...and don t press the power cord 4 The power supply voltage must be the same as the voltage given on the model board 5 To avoid hazards all installation and replacement of compo nents can only be carrie...

Страница 6: ...the main power supply 14 Please contact technical staff 15 Connectors for power plugs and extension cables must be made sure that they are watertight and must not be placed in the water Furthermore co...

Страница 7: ...g the length of the power line 2 Please check the following items before the pump startsrun ning 3 A float switch must be installed so that it is easy to switchbe tween the ON and OFF switching points...

Страница 8: ...ou set up the float switch make sure that the switch does not touch the base before the pump is opened Warning There is a risk of dry running Risk for equipment damage Do not lift the pump by cable or...

Страница 9: ...e pump and dip it into the liquid to be conveyed at a certain angle so that the lower side of the device has no bubble formation to prevent the bubbles from being sucked in Put the equipment down slow...

Страница 10: ...t 2 Clean the pump and replace worn parts Reasons Errorshooting ERROR SHOOTING In most cases you will be able to troubleshoot problems easily by yourself Before you contact us please refer to the foll...

Страница 11: ...le occasions Process equipment Products marked with adjacent symbols shall not be treated as domestic rubbish You must deal with these old electrical and electronic equipment separately Please contact...

Страница 12: ...ubmersion depth Max Grain size Max supply height 1 mm SP1040 230 V 50 Hz 1000 W IPX8 40 m 6500 l h 7 m Attention Risk for equipment damage The particle size mentioned cannot be used for simple gravel...

Отзывы: