Nakanishi AL-M1203BS2 Скачать руководство пользователя страница 2

11

English

1

. CAUTIONS FOR HANDLING AND OPERATION

 Read these warnings and cautions carefully and only use in the manner intended.

 These warnings and cautions are intended to avoid potential hazards that could result in personal injury to the 

operator or damage to the device. These are classied as follows in accordance with the seriousness of the risk.

Class

Degree of Risk

WARNING

A safety hazard could result in bodily injury or damage to the device if 
the safety instructions are not properly followed.

 

CAUTION

A hazard that could result in light or moderate bodily injury or damage to 
the device if the safety instructions are not followed.

WARNING

Handling
Connection to the Air Line Kit should be performed by a person with experience with 
compressed air and air compressors.

Air Pressure
Compressed air is required. Do not exceed an air pressure of 1.0MPa at primary side and 
0.85MPa at secondary side of the Air Line Kit.

Use of Clean Air
Do not use compressed air contaminated with chemicals, oil compounds, organic solvents, 
salinity or corrosive gasses in order to avoid damage to the device.

Connection of connection hose and supply air / oil hose
Connect the input connection hose and supply air / oil hose securely to avoid accidental 
disconnection during use. Input air pressure should never exceed 1.0MPa.
Pressure exceeding 1.0MPa may cause the connection hose and supply air / oil hose to 
rupture.

Inlet and Outlet Connections
Do not hit, impact or cause shock to the Inlet or Outlet Connector Connections. Never put undo 
stress or load on the Inlet or Outlet Connector Connections. Any damage to these components 
can cause air leakage and the inability of the inlet or outlet quick disconnect to adequately 
secure the connection hose and supply air / oil hose.

Mounting the Air Line Kit
When installing the Air Line Kit, securely install the Air Line Kit by mounting it on a at, level 
surface. If the Air Line Kit is dropped, damage to the Air Line Kit and injury to the operator is 
possible.

Electric shock
Do not touch the connection terminal, during operation of the Air Line Kit, this may cause an 
electric shock.

Air Regulator Bowl

The bowl is made of a polycarbonate.
Do not use the Air Line Kit in conditions where chemicals or organic solvents are present in 
the atmosphere.

Do not remove the bowl guard. Using the Air Line Kit without the bowl guard may cause 
injury to the operator should the bowl burst.

When removing the bowl from the regulator, remove all pressure from the Input and Outlet 
sides of the Air Line Kit.

Thank you for purchasing the Air Line Kit " AL - M1203BS2 ". This Air Line Kit is designed to adjust the air ow 
supply and provide automatic oil mist lubrication to the air tool. An air motor, spindle and compressor are required 
along with this Air Line Kit. 
Read this and all the associated component Operation Manuals carefully before use. Always keep this Operation 
Manual in a place where a user can referred to for reference at any time.

Содержание AL-M1203BS2

Страница 1: ...い 流体の種類について 使用流体は圧縮エアーを使用してください エアー圧力は 1 次側 1 0MPa 以下 2 次側 0 85MPa 以下で 使用してください 圧縮エアーについて 化学薬品 有機溶剤を含有する合成油 塩分 腐食性ガス等を含む圧縮エアーは 使用しないでください ボウルの破損や作動不良の原因になります 配管用ホース 給気ホースの接続 ホースは 確実に接続してください 使用中にホースが外れるとホースがあばれ けがをするおそれがあ ります 配管用ホース耐圧 1 0MPa 以下 を守って使用してください 継手部について 継手部に衝撃を与えたり 負荷がかかる接続をしないでください 破損によりエアー漏れや 継手が折れ て配管用ホース 給気ホースがあばれるおそれがあります 落下について エアーラインキットを取り付ける場合は 平らな面に確実に取り付けてください エアーラインキットを 落下させ...

Страница 2: ...ly air oil hose to rupture Inlet and Outlet Connections Do not hit impact or cause shock to the Inlet or Outlet Connector Connections Never put undo stress or load on the Inlet or Outlet Connector Connections Any damage to these components can cause air leakage and the inability of the inlet or outlet quick disconnect to adequately secure the connection hose and supply air oil hose Mounting the Ai...

Страница 3: ... sure to use the power source voltage of DC 24V CAUTIONS for STORAGE INSTALLATION and OPERATION Do not use the Air Line Kit where corrosive gasses chemicals seawater water oils or steam exist Do not place in direct sunlight Do not use where the Air Line Kit is subject to vibration or repetitive shock Do not use where a heat source or radiated heat exist To conform to STORAGE INSTALLATION and OPERA...

Страница 4: ...id Paraf n or equivalent Oil Reservoir Capacity 170cm3 Dimensions W490 D101 H320mm Weight 3 9Kg Operation Environment Temperature 0 40 C Humidity MAX 75 No condensation Atmospheric Pressure 800 1 060hPa Transpotation and Storage Environment Temperature 10 50 C Humidity 10 85 Atmospheric Pressure 500 1 060hPa Maximum Operating Pressure 0 6MPa Heat Resistant Class Class B Valve Seat Leakage Less tha...

Страница 5: ... Lubricator L4000 8 W LL Table 2 Air Filter Lubricator Replacing Option Name Model Manufacturer Air Filter Bowl Assy Aoto Drain Polycarbonate Bowl with Manual Cock F4000 W BOWL F CKD Air Filter Consumable Parts Kit The set includes the Louver Baf e Element and Bowl O Ring F4000 KIT Y Lubricator Bowl Assy This set includes the Bowl Assy and Bowl O Ring L4000 BOWL LL Standard Accessories Connection ...

Страница 6: ...r limit of the bowl or if air pressure is not applied to the bowl the bowl will discharge from the Drain Outlet Port by the Auto Drain Mechanism Connect a drain hose with a ȭ6mm I D Not included provided by the end user to the Drain Out Port to discharge the debris 0 4 2 1 0 MPa 8 6 Pressure Gauge H Increased L Decreased Regulator Knob Lock Release L H Fig 3 Lock and Release of the Regulator Knob ...

Страница 7: ...evel Limit of Fig 4 2 Replacing the Lubricating Oil and draining the water in the Lubricating Oil Fig 4 Remove the Oil Reservoir from lubricator drain the water in Lubricating Oil and supply the lubricating oil Oil Filler Cap Window Adjusting Dome Oil Reservoir Upper Oil Limit Lower Oil Limit 3 Adjustment of Oil Drip Rate Fig 5 O direction Increase S direction Decrease 5 5 Solenoid Operated Valve ...

Страница 8: ... Valve and Alarm Buzzer Fig 7 Solenoid Operated Valve Supply Air Oil Hose Exhaust Air Oil Hose Red Black Connection Hose Primary Joint Connector for Air Hose DC 24V Red Black Red White DC 24V DC 24V ȭ6 Filter Joint Air Motor Spindle ȭ6 One Touch Joint 6 1 Installation of the Air Line Kit 6 2 Connection of the Air Line Kit Mount it to the vertical wall on horizontal attitude Because the head of the...

Страница 9: ... One Touch joint of the Solenoid Operated Valve supply a small amount of oil directly into the supply air oil hose if bowl is completely empty Excessive oil drips An excessive amount of oil drips into the system will cause the bearings to flood slowing the speed or causing the air motor spindle speed to fluxuate Drain the Lubricating Oil in the bowl to the proper level by loosening Drain Valve Use...

Отзывы: