Naicon Diloc D.18TU Скачать руководство пользователя страница 6

3

3

SAFETY PRECAUTIONS

Do not  cover the intake or
exhaust openings with
cloths or towels.

A lack of air flow can lead 
to overheating and fire.

Never insert your finger or 
other foreign objects into grills 
or openings. Take special care 
to warn children of these 
dangers.

Do not use in areas 
where chemicals are 
handled.

This will cause the unit 
deterioration due to 
chemicals and solvents
dissolved in the air.

Care should be taken when 
using the unit in a room with
the following persons:

Infants, children, elderly people,
and people not senstive to 
humidity.

You may be injured if you

fall or if the unit falls over.

Water may spill inside the

unit, causing insulation

failure and electrical 

shock or fire.

!!

! !

It may cause failure of 
appliance or accident.

There is danger of fire or 
electric shock.

Do not place heavy object on the 
power cord and take care so that
the cord is not  compressed.

Operation without filters 

may cause failure.

Always insert the filters 
securely. Clean filter 
once every two weeks.

CAUTION

Do not climb up on 
or sit on the unit.

If water enters the unit, turn 
the unit off and disconnect the 
power , contact a qualified 
service technician.

! !

Do not place flower
vases or other water
container on top of 
the unit.

The manufactures nameplate is located on the rear panel of the unit and contains electrical and other
technical data specific to this unit.
Be sure the unit  is properly grounded. To minimize shock and fire hazards, proper grounding is important. 
The power cord is equipped with a three-prong grounding plug for protection against shock 
hazards.
Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is 
not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician 
install the proper receptacle. 
Ensure the receptacle is accessible after the unit installation.

Do not use extension cords or an adapter plugs with this unit. 

However,  if it is necessary to use an 

extension cord, use an approved   Dehumidifier  extension cord only (available at most local hardware 
stores). 
To avoid the possibility of personal injury, always disconnect the power supply to the unit, before installing 
and/or servicing.

Electrical Information

It may cause electric shock
or failure of appliance.

Содержание Diloc D.18TU

Страница 1: ...USER MANUAL D 22TU USER MANUAL PLEASE NOTE Read carefully this manual before install and or use the product Keep this manual for future consultation EN...

Страница 2: ...e 1430 volte pi elevato rispetto ad 1kg di anidride carbonica CO per un periodo 2 di 100anni In nessun caso l utente deve cercare di intervenire sul circuito refrigerante o di aprire il prodotto In ca...

Страница 3: ...lla targa del prodotto e che l impianto sia conforme alle norme vigenti 16 Pericolo di lesioni non usare il prodotto per scopi diversi da quelli per cui stato costruito Non fare uso errato dell appare...

Страница 4: ...k of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play the appliance...

Страница 5: ...rd Do not place the unit near a heat source Before cleaning turn off the power and unplug the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc CAUTIO...

Страница 6: ...unit If water enters the unit turn the unit off and disconnect the power contact a qualified service technician Do not place flower vases or other water container on top of the unit The manufactures n...

Страница 7: ...to initiate the Auto start and Auto stop feature in conjuction with the and key pads 1 1 1 1 2 2 3 3 4 4 5 5 6 6 7 7 Unit operation on indicator light 8 8 High fan indicator light Timer on off indica...

Страница 8: ...error Unplug the unit and plug it back in If error repeats call for service ES Temperature sensor error Unplug the unit and plug it back in If error repeats call for service Auto Restart If the unit b...

Страница 9: ...automatically controlled according to the actual room humidity The unit will quit dryer mode after a maximum 10 hours operation NOTE The Dryer mode must be operated in a close room do not open the do...

Страница 10: ...spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of...

Страница 11: ...e bucket is restored in its correct position NOTES When you remove the bucket do not touch any parts inside of the unit Doing so may damage the product Be sure to push the bucket gently all the way in...

Страница 12: ...should be checked and cleaned at least every 30 days or more often if necessary NOTE DO NOT RINSE OR PUT THE FILTER IN AN AUTOMATIC DISHWASHER To remove Grip the tab on the filter and pull it upward t...

Страница 13: ...idity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C 41 O O F There is a kerosene heater or something givin...

Страница 14: ...ge and or defects resulting from modifications or adaptations made to the product without prior written authorization issued by Naicon in order to conform it to technical or technical standards nation...

Страница 15: ...Note...

Страница 16: ...Naicon SRL Via il Caravaggio 25 Trecella I 20060 Pozzuolo Martesana Milan Italy Tel 39 02 95 003 1 Fax 39 02 95 003 313 www naicon com e mail naicon naicon com made in China...

Отзывы: