Naicon Diloc D.18TU Скачать руководство пользователя страница 11

8

8

OPERATING THE UNIT

Removing the collected water

1. Pull out the bucket  a little.

2. Hold both sides of the bucket

with even strength, and pull it
out from the unit.

3. Pour the water out.

There are two ways to remove collected water.
1. Use the bucket

When the unit is off,if the bucket is full, the unit will 

beep 8 times and the Full indicator light will flash, the 
digital display shows P2.
When the unit is on,if the bucket is full, the compressor 
turns off and the fan turns off after 30 seconds for drying
the water of the condenser, then the unit  will beep 8 
times and the Full indicator light will flash, the digital 

display shows P2.

Slowly pull out the bucket. Grip the left and right 
handles securely, and carefully pull out straight so 
water does not spill. Do not put the tank on the floor 
because the bottom of the bucket is uneven. Otherwise 
the bucket will fall and cause the water to spill.
Throw away the water and replace the bucket. The 
bucket must  be in place and securely seated  for the 
dehumidifier to operate.
The machine will re-start when the bucket is restored
in its correct position.

NOTES:

    When you remove the bucket, do not touch any parts 
     inside of the unit. Doing so may damage the product.
     Be sure to push the bucket gently all the way into the 
     unit. Banging the bucket against anything or failing to 
     push it in securely may cause the unit not to operate.
     When you remove the bucket,if there is some water in
     the unit you must dry it .

Fig.5

Fig.6

2. Continuous draining

Fig.7

Water can be automatically emptied into a floor 
drain by attaching the unit with a water hose
(not included).
Remove the rubber plug from the back drain
hose outlet. Attach a drain hose(ID=13.5mm)
and lead it to the floor drain or a suitable
drainage facility(see Fig.7).
Make sure the hose is secure so there are no leaks.
Direct the hose toward the drain,making sure that
there are no kinks that will stop the warter flowing.
 Place the end of the hose into the drain and make sure
the end of the hose is level or down to let the water flow
smoothly.Do never let it up.
Select the desired humidity setting and fan speed 
on the unit for continuous draining to start.

NOTE: When the continuous drain feature 
is not being used,remove the drain hose 
from the outlet.

Attach the hose 
to the drain 
hose outlet.

Remove the 
rubber plug

Содержание Diloc D.18TU

Страница 1: ...USER MANUAL D 22TU USER MANUAL PLEASE NOTE Read carefully this manual before install and or use the product Keep this manual for future consultation EN...

Страница 2: ...e 1430 volte pi elevato rispetto ad 1kg di anidride carbonica CO per un periodo 2 di 100anni In nessun caso l utente deve cercare di intervenire sul circuito refrigerante o di aprire il prodotto In ca...

Страница 3: ...lla targa del prodotto e che l impianto sia conforme alle norme vigenti 16 Pericolo di lesioni non usare il prodotto per scopi diversi da quelli per cui stato costruito Non fare uso errato dell appare...

Страница 4: ...k of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play the appliance...

Страница 5: ...rd Do not place the unit near a heat source Before cleaning turn off the power and unplug the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc CAUTIO...

Страница 6: ...unit If water enters the unit turn the unit off and disconnect the power contact a qualified service technician Do not place flower vases or other water container on top of the unit The manufactures n...

Страница 7: ...to initiate the Auto start and Auto stop feature in conjuction with the and key pads 1 1 1 1 2 2 3 3 4 4 5 5 6 6 7 7 Unit operation on indicator light 8 8 High fan indicator light Timer on off indica...

Страница 8: ...error Unplug the unit and plug it back in If error repeats call for service ES Temperature sensor error Unplug the unit and plug it back in If error repeats call for service Auto Restart If the unit b...

Страница 9: ...automatically controlled according to the actual room humidity The unit will quit dryer mode after a maximum 10 hours operation NOTE The Dryer mode must be operated in a close room do not open the do...

Страница 10: ...spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of...

Страница 11: ...e bucket is restored in its correct position NOTES When you remove the bucket do not touch any parts inside of the unit Doing so may damage the product Be sure to push the bucket gently all the way in...

Страница 12: ...should be checked and cleaned at least every 30 days or more often if necessary NOTE DO NOT RINSE OR PUT THE FILTER IN AN AUTOMATIC DISHWASHER To remove Grip the tab on the filter and pull it upward t...

Страница 13: ...idity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C 41 O O F There is a kerosene heater or something givin...

Страница 14: ...ge and or defects resulting from modifications or adaptations made to the product without prior written authorization issued by Naicon in order to conform it to technical or technical standards nation...

Страница 15: ...Note...

Страница 16: ...Naicon SRL Via il Caravaggio 25 Trecella I 20060 Pozzuolo Martesana Milan Italy Tel 39 02 95 003 1 Fax 39 02 95 003 313 www naicon com e mail naicon naicon com made in China...

Отзывы: