>300/1
1.8"
>2000/
78"
>600/23.6"
>300/1
1.8"
>600/2
3.
6"
NOTE:
The minimum distance
between the outdoor unit and walls
described in the installation guide
does not apply to airtight rooms.
Be sure to keep the unit unobstructed
In at least two of the three directions
(Front,Left,Right).
(As shown on the right)
Drilling Hole In Wall
You must drill a hole in the wall for the refrigerant piping, and the signal cable that will
connect the indoor and outdoor units.
1. Determine the location of the wall hole according to the location of the outdoor unit.
2. Use a 65 mm (2.5 ") core drill to drill holes in the wall.
3. Place the cuff on the hole. This protects the edge of the hole and helps seal the hole
when the installation process is complete.
NOTE:
When drilling the wall hole, make sure to avoid wires,
plumbing, and other sensitive components.
Outdoor unit condensed water drainage(Optional)
The condensed water and the ice formed in the outdoor
unit during heating operation can be drained away thro-
ugh the drain pipe
1.Fasten the drain port in the 25mm hole placed in the
part of the unit as shown in the picture.
2.Connect the drain port and the drain pipe.
Pay attention that water is drained in a suitable place.