S4600-24X2CInstallation Instruction Manual
3 First power-on and start the switch
NADDOD Pte. Ltd.
22
Step 2.
Setting the terminal parameters (taking the setting of hyperterminal of Windows XP as an
example). The specific methods are as follows:
1. Click the “Start Menu
Programs
Accessories
Communications
Hyperterminal”, enter the
window of hyperterminal, and creat a new connection. The system will pop up the connection
instruction interface as shown in the figure.
Figure 3-2
Create a new connection
2. Enter the new connection name (e.g., Network) in the connection instruction interface, click the
button of “OK”, the system will pop up the interface as shown in the following figure, and select
the serial port to be used by the connection in the column of [Connect using].
Figure 3-3
Set port connection
3. After selecting the serial port, click the button of <OK>, the system will pop up the parameter
setting interface of connection serial port, set the bits per second as 115200, the data bits as 8, the
odd-even check as none, the stop bits as 1, and the data flow control as none. (In other Windows