4.3 EtherNet/IP master settings
4-5
4.3 EtherNet/IP master settings
4.3.1 Fieldbus settings
Protocol settings
1
Open <Constant Setting> - [8 Communication] - [3 Fieldbus] screen.
>> The following screen will appear.
2
Align the cursor with the combo box of the “Channel” in which EtherNet/IP is to
be used, and press the [Enter].
>> Select “AnyBusEtherNet/IP”, and press the [Enter].
+
3
Use the [Enable] + [Left] or [Right] cursor keys to switch to the radio buttons (a
horizontal row of selector buttons), and select “MASTER”.
4
Align the cursor with the combo box of “Slot ID”, and press the [Enter].
>> Select the Slot ID in which the field bus base board is installed, and press the
[Enter].
INFO.
The slot ID is required in order to specify the slot position where the EtherNet/IP board is
installed. For the relationship between the slot position and the slot ID, refer to “1.2.3
Hardware Configuration”.
5
Input the module number in the edit box of “module”, and press the [Enter].
INFO.
“Module” is a number that specifies the position of the module on field bus base board. When
“0” is set, the channel is disabled. For the position of the module, refer to “1.2.4 Hardware
Setting”.
Now proceed to set the EtherNet/IP (master).