Magnum 4A Control Wiring & Adjustment Manual
Part #15-10682
Rev. 7-03-14
4-16
Adjustments and Status LEDs
Section 4c. Status LEDs
(2) LED Indicators are used to display what the Magnum 4A Control
is reacting to
at any instant
within the Swing door cycle. This helps to identify when the Swing door system is functioning
properly. Please see Figure 4-4.
Figure 4-4
LED Indicators
DN 0558
Red LED
Green LED
LED
TRANSFORMER
AUX
PWR
J2
F1
TDAS
SIGNAL
INPUT
TDPG
LCHK
CLOSE
Fuse 1: 0.5A 24 VAC
STOP
OPEN
BCHK
J1
Table 4-3
Status LED Indicators
LED
Status
Description
Green
Cycle
Indicates door position during an open and closed cycle.
Indicator
Action
Fast Flashing
(2 flashes per second)
Door is opening.
On Solid
Door is in Back Check.
Slow Flashing
(1 flash per second)
Door is closing.
Off
Door is in Latch Check or Closed
Red
Safety Indicates state of the (2) Safety Signals, or the state of the Current Limit at any instant during the
Swing door cycle.
Indicator
Action
Slow Flashing
(1 flashes per second)
X
Door mounted Sensor on Swing side of door is activated.
X
Continuous Safety.
Fast Flashing
(2 flashes per second)
X
Header Mounted Sensor on Swing side of door is
activated.
X
Safety with Lockout.
On Solid
X
Current Limit is activated.
Содержание Magnum 4A Control