Nabco Gyro Tech Acuvision Скачать руководство пользователя страница 20

Page 20 

www.NabcoEntrances.com 

05-11-10 

Acuvision Instruction Manual 

D.7) Troubleshooting 

 

D.7.1)  Sensor symptoms and how to solve them 

 

 

 

D.7.2)  Sensor symptoms using wrong Door Mode settings

 

Symptoms 

Possible Causes 

Measures 

No 
Function 

Power

Connector Defects 

Check Wiring Cable and Connector 

Abnormal Power Voltage 

Rated Voltage for This Sensor is 12

24V AC/DC.     Do not 

apply voltages other than the rated voltages. Use Class 2 power 
supply. 

No 
Detection 

Sensor Lens is stained with 
dirt, water, etc. 

Wipe off the stain with neutral detergent applied soft cloth. (Do 
not use such chemicals as Thinner or Alcohol, etc.) 

Low Sensitivity 

Set higher sensitivity 

Wrong Detection Area Set-
ting  

Make readjustments with Area Setting Switches, Area Setting 
Lever, Area Fine Adjustment Mechanism 

Mis-detection 

High Sensitivity 

Lower Sensitivity at the Setting Switch. 

Detection Area Overlapped 
by other Detecter(s) 

Set the different Interference Prevention Modes by setting 
switches. 

Not Detecting Door 

Check to ensure Detection Area is tilted toward Door panel. 

Movable Object(s) placed in 
Detection Area 

Readjust the Detecting Area to avoid objects or remove the ob-
ject(s) to outside the Detection Area. 

Conditions in Detection Ar-
ea altered 

When conditions in Detection Area change, the Sensor keeps 
on detecting as long as the time set for Presence Detection. 
Shorten the Presence Detection Time at the setting switch. 

Operation Display Red LED 
Blinks Several Times at Ful-
ly Opened Position 

Detection is made by Door Detector.  Lower the sensitivity. 
(Example: SW4=OFF, SW5=ON ) 

Operation Display Amber 
LED  Blinks Several Times 
at Fully Open Position 

Detection is made by Door Detector. Lower the sensitivity. 
( Example: SW4=OFF, SW5=ON ) 

Operation Display Green LED Blinks 

The sensor does not recognize the movement of Door. Readjust 
the area toward Door side by Area Fine Adjustment Mechanism. 

Operation Display Red LED Blinks 

Self-Diagnosis Function Determines the unit Out of Order. 

Standstill Memory Time (Learn Time) is 
Short 

After turning power on, allow up to 3 minutes without anyone 
entering the detection pattern for the sensor to stabilize.  

Mode 
Type 

Folding Door Setting 

Sliding Door Setting 

Swing Door Setting 

Folding Door 

○ 

Normal Operation 

Repeated reverse motions or 
opens at fully closed posi-
tion. 

  Operational 

Sliding Door 

No activating signal at fully 
closed position, thus no 
opening door. 

○ 

Normal Operation 

No activating signal  at fully 
closed  position,  thus  no 
opening door. 

Swing Door 

  Operational 

Repeated reverse motions or 
opens at fully closed posi-
tion. 

○ 

Normal Operation 

Содержание Gyro Tech Acuvision

Страница 1: ...rating Instructions contained in this manual Failure to do so may result in property damage or bodily injury Acuvision Instruction Manual WARNING Turn OFF all power to the Automatic Door if a Safety S...

Страница 2: ...on detection zone 12 D 4 3 Minute adjustment of depth coverage 13 D 4 4 Adjusting for Width Coverage 13 D 4 5 Setting Width coverage 14 D 4 6 Operation Mode Set Up D 4 6 1 Mutual Interference Preventi...

Страница 3: ...ion will memorize the door swing area and door position during the first activation cycle During the door cycle the Acuvision will also scan the threshold area and store this information into its memo...

Страница 4: ...x Resistance load Semiconductor Relay No Detection OPEN Detection CLOSED Power failure OPEN Mounting height Max 118 above detection area Detection area when mounted at a height of 118 118 3000mm Width...

Страница 5: ...al C Appearance and Dimensions Figure 1 Appearance 8 66 220mm Mounting Pitch 7 87 200mm 1 34 34mm 3 0 76mm Sensor is interchangeable with Acusensors and Acumotion 8 pin Connector Dip Switches 1 8 Dept...

Страница 6: ...hims can be used to make the necessary adjustments The unit must be mounted such that it detects the door and still provides adequate threshold protection Under normal circumstances the unit will be m...

Страница 7: ...to wind or stack pressure this input signal may be required in order for the sensor to recognize when the door is in the fully closed position A mechanical or magnet ic door closed switch is necessar...

Страница 8: ...Quick Disconnect connector off main microprocessor harness as shown Wire nut Acuvision harness to main harness as shown below Mount the Acuvision Sensor Note Acuvision dipswitch Settings 9 ON 10 OFF D...

Страница 9: ...GREY YELLOW BLUE WHITE BLACK GREEN INPUT INPUT COM OUTPUT 2 N O OUTPUT 2 COM OUTPUT 1 COM OUTPUT 1 N O HOLE ON THE HEADER COVER ACUVISION HARNESS TERMINAL 1 TERMINAL 2 NOT USED TERMINAL 5 NOT USED NOT...

Страница 10: ...NUM BOARD TERMINAL BLOCK CONNECTIONS DOOR CLOSED INPUT SEE NOTE ON PG 18 ACUVISION HARNESS 12 24 VOLTS AC DC 12 24 VOLTS AC DC NOT USED BLUE WHITE BLACK GREEN OUTPUT 2 N O OUTPUT 2 COM OUTPUT 1 COM OU...

Страница 11: ...ng something new in the detection area CAUTION Confirm that the wiring is correct before turning on the power Turn power off before making adjustments to the sensor D 4 Customized Settings The followi...

Страница 12: ...s in field measurements procedures and conditions from ANSI standards 4 Use of spacers for mounting Depth Adjustment Lever Position 1 Position 2 Position 3 Position 4 Position 5 Figure 2 Depth of cove...

Страница 13: ...ed too high on the header Refer to page 7 Do not use the adjustment knob to widen the detection area D 4 4 Adjusting for Width Coverage The width coverage is achieved in seven increments as shown belo...

Страница 14: ...light intensity reflected from the floor surface in the detection area The detection area is the reference area as determined by the Acuvision Detection sensitivities can vary depending on the color o...

Страница 15: ...activates unnecessarily use the lower sensitivity When low or snow sensitivity is used care must be taken to assure that adequate sensing is maintained D 4 6 4 Standstill memory time Learn Time The Ac...

Страница 16: ...es within the memorized detection area whether on the floor or above the floor will generate a signal to open the door The base memory pattern will be re learned automatically after the selected memor...

Страница 17: ...correct this make adjustments using the Area Minute Adjustment Mechanism to tilt the detection area in toward the door If the amber LED is blinking when door is at full open position or while door is...

Страница 18: ...ensitivity See pages 16 in this Instruction Manual D 6 5 Moving items If you have a short split curtain flowerpot or any other items that may shake in the detection area the Acuvision may falsely acti...

Страница 19: ...ere rain or snow falls on it ghosting or damage to the sensor may occur In this case use Acusensor Rain Cover P N 14 10278 D 6 10 Changes in background conditions If the background condition within th...

Страница 20: ...Area Conditions in Detection Ar ea altered When conditions in Detection Area change the Sensor keeps on detecting as long as the time set for Presence Detection Shorten the Presence Detection Time at...

Отзывы: