Page 17
www.NabcoEntrances.com
05-11-10
Acuvision Instruction Manual
.5 Output
Output LED Indicator
D.6 Usage Tips
D.6.1)
Door Panel Detection
For the Acuvision to work correctly, it must detect the door panel. If necessary use the Area
Minute Adjustment Mechanism to enable the detection area to reach the door panel, otherwise
the position of the door can not be detected resulting in improper operation. Use the LED
display as follows to confirm that the sensor detects the door panel.
When the green LED is blinking, the sensor is not detecting the door panel. When this happens,
auto-recognition will not function correctly. To correct this, make adjustments using the Area
Minute Adjustment Mechanism to tilt the detection area in toward the door.
If the amber LED is blinking when door is at full open position, or while door is opening from
mid-point of travel to full open, adjust the detection area outward away from the door.
(See page 13 in this Instruction Manual.)
D
Note:
Refer to page 7. If the sensor doesn’t reliably recognize the fully closed door position, a closed
Status
Power
Off
Power On
Stand by
Detecting
Mis-detection
Out of order
Fully
closed
position
Positions other
than fully
closed
Normal
Presence
Detection
Operation
Display
LED’s
off
Green LED
on
LED’s off
Red LED
on
Amber LED
on
Respective
LED Blinks
Red LED
Blinks
Continuously
N/A
DN0189
or non-swing
side for swing
or non-fold
side of folding
doors
Right bank
of switches
9 - 16