6 of 38
GT 300-350-8300-8350 Opus Overhead Concealed Swing Door Installation Manual
www.NabcoEntrances.com
P/N C-00175
Rev 5-23-18
SECTION 4 .2: Power Configurations
4 .2 .1 Full Power Swing Doors
X
Utilize Sensor(s) to open a Swing door.
• Sensors activate the Control by detecting motion of pedestrians (or moving objects) that come into range.
X
Must be compliant with ANSI Standard Code 156.10 to reduce chance of injury to pedestrians and wheeled traffic.
4 .2 .2 Low Energy Swing Doors
X
Utilize a Knowing Act to open a Swing door.
• A conscious effort that is carried out in many different ways, including (but not limited to): manually opening/
closing a Swing door; pressing various types of Push Plates; turning a Key switch; flipping a Rocker Switch;
utilizing a keypad or card reader, etc.
X
Must be compliant with the ANSI Standard Code 156.19 to reduce chance of injury to pedestrians and wheeled traffic.
SECTION 4 .3: Door Frame Specifications
Specification
Measurement
Minimum Frame Face for Mounting
1-3/4 inches (44mm)
Minimum Clearance from Top of Door to Ceiling
Bottom Load
Side Load
6-1/8” (156 mm)
7-18” (181 mm)
Minimum Door Thickness
1-3/4 inches (44 mm)
SECTION 4 .4: Handing
DN0461
Inswing
Single
Right Hand
Inswing
Single
Le Hand
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
Simultaneous
Outswing Pair
Simultaneous
Inswing Pair
Outswing
Single
Right Hand
Outswing
Single
Le Hand
Dual Inswing
Outswing Pair
Dual Inswing
Outswing Pair
CHAPTER 5: INSTALL THE BOTTOM LOAD DOOR FRAME
SECTION 5 .1: Prep the Bottom Load Header
1. Place Header on flat surface with Bottom facing up. Protect Header from scratches.
2. Remove #10-24 x 3/4 inch screws and Dress Plate. Set aside.
3. Mark the locations of each Lock Cover Plate to ensure it is reinstalled in the correct position.
4. Remove Lock Cover Plates from bottom of Header, then boxes and/or parts bags from inside Header. Set Aside.