background image

APPENDIX

DMX 

PRIMER

There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable
of receiving DMX 512 will require one or a number of sequential channels. The user must assign a starting
address on the fixture that indicates the first channel reserved in the lighting console. There are many different
types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a
start address should be planned in advance. Channels should never overlap. If they do, this will result in erratic
operation of the fixtures whose starting address is set incorrectly. You can, however, control multiple fixtures of
the same type using the same starting address as long as the intended result is that of unison movement or
operation. In other words, the fixtures will be slaved together and all respond exactly the same.

DMX fixtures are designed to receive data through a DMX Chain. A DMX chain connection is where the DMX
OUT of one fixture connects to the DMX IN of the next fixture. The order in which the fixtures are connected is
not important and has no effect on how a lighting console communicates to each fixture. Use an order that
provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor twisted pair
cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is data Negative
(S-) and pin 3 is data positive (S+). Company NA carries 3-pin and 5-pin XLR DMX compliant cables.

G

ENERAL

 

MAINTENANCE

To   maintain   optimum   performance   and   minimize   wear   fixtures   should   be   cleaned   frequently.   Usage   and
environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at
least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead
to   reduced   lamp   life   and   increased   mechanical   wear.   Be   sure   to   power   off   fixture   before   conducting
maintenance.

Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust collected on
external vents and internal components. Clean all glass when the fixture is cold with a mild solution of glass
cleaner or isopropyl alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to the cloth or tissue
and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they are free of haze and
lint.

The cleaning of internal and external optical lenses and/ or mirrors must be carried out periodically to optimize
light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or
particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics. Clean with soft cloth
using normal glass cleaning fluid. - always dry the parts carefully. – clean the external optics at least every 20
days. Clean the internal optics at least every 30 / 60 days.

23

Содержание MultiFlash Series

Страница 1: ......

Страница 2: ...rts are present and in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear to be damaged from shipping or if the carton itself shows signs of m...

Страница 3: ...amaged Never disconnect the power cord by pulling or tugging on the cord Avoid direct eye exposure to the light source while it is on Caution There are no user serviceable parts inside the unit Do not...

Страница 4: ...must be daisy chained in one single line To comply with the EIA 485 standard no more than 32 devices should be connected on one data link Connecting more than 32 fixtures on one serial data link witho...

Страница 5: ...so operate in any orientation Always make sure there is adequate room for ventilation Do not obstruct the unit s fan or vents Support Stand Always use a professional stand rated to support weight grea...

Страница 6: ...MENU button to access the menu function currently displayed or to enable a menu option To return to the top of the menu map or menu without changing the value press the X button Main Menu Functions Ma...

Страница 7: ...Menu Map MultiFlash MultiFlash Q MultiFlash LR Q MultiFlash Rayzr 7...

Страница 8: ...Menu Map MultiFlash JR 8...

Страница 9: ...in Menu 2 Use UP and DOWN buttons to find the DMX address function 3 Press SELECT button to access the DMX address value change submenu 4 Use UP and DOWN buttons to set necessary DMX address value e g...

Страница 10: ...ntrol MultiFlash fixtures are two fixtures in one strobe and a wash blinder fixture In each of the control modes the fixture occupies varying numbers of DMX channels and has different control channels...

Страница 11: ...olution The RGB modes are designed to automatically adjust the white LEDs according to the RGB mix coming from the lighting controller The RGBW modes are designed to give independent control of all 4...

Страница 12: ...Strobe and RGBW Strobe modes a feature in the Strobe FX channel allows the MultiFlash to become a temporary wash blinder fixture If the Strobe FX channel is set to DMX value 5 the Strobe color channel...

Страница 13: ...background pixels run at burst speed in this mode The foreground strobe is randomized which is not achievable in any other mode and is difficult to reproduce with most DMX controllers at this rate ASY...

Страница 14: ...5 the Strobe color Channels become strobe wash blinder color and Strobe Intensity is used as a master intensity channel For example you can be strobing in White and then quickly change the fixture in...

Страница 15: ...idual segments pixels RGB or RGBW control can be selected plus the desired pixel segments The LED segments are comprised of 8 LEDs There are two segments of 8 LEDs per row There are 6 rows of LEDs for...

Страница 16: ...xel groups In advanced controlling modes MultiFlash MultiFlash Q and MultiFlash LR Q may be controlled as a wash with 1 2 3 4 6 or 12 pixel modes Note Only the entire fixture can be strobed Operators...

Страница 17: ...y to simulate strobing of individual segments However strobe functions and strobe color can only be set for the whole fixture Pixel Locations MultiFlash Rayzr MultiFlash Rayzr Q 1m consists out of 36...

Страница 18: ...ADVANCED RGB STROBE DMX CHANNELS 18...

Страница 19: ...ADVANCED RGBW STROBE DMX CHANNELS 19...

Страница 20: ...always is turned on Note MultiFlash Q MultiFlash Rayzr and MultiFlash LR Q have a Power Fan menu category In this menu you have three modes Turbo Mode Full Power full fans when needed Theater Mode Red...

Страница 21: ...se and power source There are two options 50Hz and 60Hz Use the UP and DOWN buttons to change these values Reset Set factory defaults Two options NO and YES Use the UP and DOWN buttons to change these...

Страница 22: ...g green and white colors red and blue tend to be similar After color hue has been matched do a color intensity calibration again as changing color hue changes intensity as well This has to be done onl...

Страница 23: ...nectors The shield connection is pin 1 while pin 2 is data Negative S and pin 3 is data positive S Company NA carries 3 pin and 5 pin XLR DMX compliant cables GENERAL MAINTENANCE To maintain optimum p...

Страница 24: ...its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you have RMA please include the following information on a...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...28...

Страница 29: ...29...

Страница 30: ...30...

Отзывы: