NA-DE 10465 Скачать руководство пользователя страница 2

SPECIFICATIONS

10465

Operating voltage

Angle of coverage

Height

Detection range

Time setting

Lighting load

Protection class

Opr. temperature

Mounting section size

230-240V~   50/60 Hz

360°

2.8 m.

6 -24 m. (adjustable)

10 sec. 

±

 1 sec. / 5 min. 

±

 10 sec.

Max 2000W incandescent

Max 800W fluorescent

IP20   Class II

-20 °C ~ +40°C

Ø 130 mm

10465

e-motion 360° digital motion sensor ( trio sensor )

Detection range is determined at the temperature of +20°C

DETECTING RANGE

SETTING

[email protected]     •     www.na-de.com.tr

Walking targential to the sensor

(normal detection range)

Walking directly to the sensor

(lower detection range)

Figure 1

TROUBLESHOOTING

MALFUNCTION

CAUSE

SOLUTION

• Lamp is off

• There is no
electricity on the
device

• Continuously
lamp is on

• Change perception
area in device

• Daylight adjustment set to
night-time mode during daytime
operate
• Bulb faulty or there is no
connection
• Power switch off or no electricity

• Fuse faulty

• Fuse switch off or fuse faulty

• Connection faulty.

• Continuously movement in
detection zone
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
trees & bushes or open windows in
detection zone.

• Sudden temperature changes due
to weather(wind, rain, snow) or the
air expelled from fans.
• Different ambient temperatures.

• Control daylight setting and
re-adjust
• Fit the bulp into the lamp holder,
if it still does not operate, change
the bulb.
• Check the electricity and power
on.
• Change the fuse.

• Check the fuse if necessary use
a new fuse.
• Check the connection cables.

• Check the detection zone.

• Avert it is being detection.

• Change detection zone, change
site of installation.

• Change site of installation or
keep the reasons away.

• Change site of installation.

N N N

LS L L

(Notr)

(Line)

(Lamp)

24 m

2.8 m.

12 m.

(max)

(min)

(e)

(f)

(g)

TIME

LUX

SENSE

(max)

(min)

(max)

(min)

(e) Time setting

Light ON time can be adjusted continuously from
“10 sec. 

±

 1 sec. / 5 min. 

±

 10 sec.” If you turn the knob 

anticlockwise

 device

will operate at minimum time. (10 seconds)

Control dial set to  - = Shortest time (10 sec. 

±

 1 sec.)

Control dial set to + =  Longest time (5 min. 

±

 10 sec.)

(f) Daylight setting

The sensor’s response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob 

anticlockwise

 device will operate at dark.

Control dial set  +  = daylight operation approx. 2000 lux.
Control dial set  -  = night-time operation approx. 2 lux.

(g) Detection Range Setting (SENSE)

SENSE adjustment is used to set the detection range. For optimum range, please set the knob
to middle point. For maximum range (24 m) please turn clockwise, for minimum range (6 m)
turn anti-clockwise.

NOTE:

 Device will automatically make its own offset by checking environment for approximately

5 minutes after the first installation. After this period device will operate normally. If you think
the device does not operate normal in first installation, please wait for 5 minutes and start to
test again. Be sure that there is no motion by this period.

DETECTION AREA

Detection area of motion sensors depends on the angle between PIR detector and moving
direction, temperature , mounting style and mounting place. Temperature is very important for
operation for motion sensor like all electronic devices. Using higher value of loads written on
manuals and packages will decrease temprature inside the device when using Na-De Motion
Sensor. As a result detection range will decrease and may cause defect of electronic components.
Environment temperature will also cause decrease of detection range. Detection range give is
determined at +20°C. If the weather is hot, it will decrease.

The maximum detection range can be realized when walking tangential to  the sensor (figure1)
When walking directly to the sensor detection range will be low. Because you will not be able
to cut vertical areas. Detection range of Na-De Motion Sensors is 24 meters as diameter, 12
meters as radius.

GUARANTY

We will remedy defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement at our own discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well
packed complete with a brief description of the fault, a receipt or invoice ( date of purchase and
dealer’s stamp) to the appropriate Service Center.

Mounting

(a)

(b)

After placing the long parts of the both springs inside the slot and short parts
of the both springs out  of the slot on the ceiling as shown on the Figure (a), press
 the product through the slot and  make the springs tense as shown on the
figure (b). Thus, installation is achieved successfully.

KK-10465_150310_EN_00

12 m.

General Spesifications

• It detects your motion automatically when you move and it turns on lightings connected.
• Digital microprocessor sensor technology provides perfect detection. The item is available
for indoor usage.

USAGE AREAS

• At the building entrances, stair vestibutes.
• At the long halls within the flats.
• At the places required within the flats.
• At covered parking lots.
• At the requisite locations within the hotels.
• At the schools, hospital and oil filing station.

“OFFERS ENERGY SAVING FEATURE’’

GENERAL SECURITY CAUTIONS

• Take off the original package and control if there is any damage of transportation and general
view of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply any liquid.
• Protect from any stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist electricians must install
and apply.

CAUTIONS FOR INSTALLATION AND USAGE

• Installing must be carried out professionally in accordance with applicable national wiring and
electrical operating conditions.
• Turn of the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Place the product horizontal to the ceiling.
• Fix the bulbs before operating.
• Use 10A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 10 - 15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting of the time
and daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that
you can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the product, take of carefully and clean with a dry rag.
• Avoid mounting the detector close to objects that can cause rapid temperature changes such
as heaters, fans, refrigerators and ovents etc, and prevent the detector from point-blank
sunshine.
• It can cause the device operate inaccurately if there is tree, brushes etc. in the coverage area.

Complies with ROHS Regulation Directive

2002/95/EC

Отзывы: