background image

SER-485-IR_2510 R3 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N-Tron Corp. 

820 S. University Blvd. Suite 4E, Mobile, AL 36609 

PH: 251-342-2164 · FAX: 251-342-6353

 

1

1

.

.

 

 

C

C

h

h

e

e

c

c

k

k

 

 

f

f

o

o

r

r

 

 

R

R

e

e

q

q

u

u

i

i

r

r

e

e

d

d

 

 

H

H

a

a

r

r

d

d

w

w

a

a

r

r

e

e

 

 

  SER-485-IR Isolated Repeater 

  This Quick Start Guide 

  Additional Items Required but not included 

o

  A 10 to 48 VDC Power Supply.  

o

  RS-422/485 Cables.   

 

2

2

.

.

 

 

I

I

n

n

f

f

o

o

r

r

m

m

a

a

t

t

i

i

o

o

n

n

 

 

 

 

U

U

L

L

 

 

C

C

l

l

a

a

s

s

s

s

 

 

1

1

 

 

D

D

i

i

v

v

 

 

2

2

 

 

1. Power, input /output (I/O) wiring must be in 

accordance with Class 1 Division 2 wiring methods 
[Article 501.10(B) of the National Electric code, 
NFPA70] and in accordance with the local authority 
having jurisdiction.  

2. Maximum ambient air temperature 80°C 
3. 

WARNING – EXPLOSION HAZARD: 

SUBSTITUTION OF COMPONENTS MAY IMPAIR 
SUITABLITY FOR CLASS 1, DIVISION 2. 

4. 

WARNING –

 

EXPLOSION HAZARD: 

WHEN IN 

HAZARDOUS LOCATIONS, TURNING OFF 
POWER BEFORE REPLACING OR WIRING 
MODULES 

5. 

WARNING – EXPLOSION HAZARD: 

DO NOT 

DISCONNECT EQUIPMENT UNLESS POWER HAS 
BEEN SWITCHED OFF OR THE AREA IS KNOWN 
TO BE NON-HAZARDOUS. 

6. 

WARNING –

 THIS APPARATUS IS SUITABLE FOR 

USE IN CLASS 1 DIVISION 2, GROUPS A, B, C, 
AND D, OR UNCLASSIFIED AREAS

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Quick Start Guide 

SER-485-IR 

Triple Isolated RS-422/485 

Repeater 

3

3

.

.

 

 

I

I

n

n

f

f

o

o

r

r

m

m

a

a

t

t

i

i

o

o

n

n

 

 

 

 

F

F

r

r

o

o

n

n

t

t

 

 

P

P

a

a

n

n

e

e

l

l

 

 

 

 

 

 
Front Panel 

Power TB 

2 Position, Removable 

DATA LED 

Red, Flashes when RS-422/485 

 

 

Data Received on TB1 

TB 1 

5 Position, Removable 

TB 2 

5 Position, Removable 

DATA LED 

Red Flashes when RS-422/485 

 

 

Data Transmitted on TB2 

Power LED 

Red, ON When Power Applied 

Dip Switch 

12 Position, One on the top of the  

 

 

Unit, on the bottom of the unit 

 
 
RS-422/485 Terminal Blocks  

TB1 

RS-485 2-Wire 

RS-422/485 4-Wire 

GND 

GND 

Data B(+) 

RDB(+) 

Data A(-) 

RDA(-) 

--- 

TDB(+) 

--- 

TDA(-) 

 

 

 

TB2 

RS-485 2-Wire

 

RS-422/485 4-Wire

 

GND 

GND 

Data B(+) 

RDB(+) 

Data A(-) 

RDA(-) 

--- 

TDB(+) 

--- 

TDA(-) 

 

4

4

.

.

 

 

I

I

n

n

f

f

o

o

r

r

m

m

a

a

t

t

i

i

o

o

n

n

 

 

-

-

 

 

D

D

I

I

P

P

 

 

S

S

w

w

i

i

t

t

c

c

h

h

 

 

 

Communications

 Mode 

 

RS-485 

ON 

ON 

ON 

ON 

2-Wire 

Half Duplex 

RS-485  

ON 

OFF 

OFF 

OFF 

4-Wire 

Full Duplex 

RS-422 

OFF 

OFF 

OFF 

OFF 

Full 

Duplex 

 

Termination Resistor 

 

Use the 120Ω  

ON 

Built in Termination 
Use External  

OFF 

or no termination 

 

Transmit Bias 

 

Use the 1.2KΩ 
Transmit 

OFF 

Bias Resistor 
Use External or no  

ON 

Transmit Bias Resistor 

 

Receive Bias 

 

Use the 1.2KΩ Receive 

OFF 

Bias Resistor 
Use External or no  

ON 

Transmit Bias Resistor 

 
 

Отзывы: