![N-Tron 708M12 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/n-tron/708m12/708m12_user-manual-and-installation-manual_3191386015.webp)
(Revised 2012-10-5)
Page 15 of 169
Applying Power
708M12 716M12
The M12 A coded power connector is keyed, where the mating connection from the power supply
can be made only when the male and female ends are lined up properly.
When the power is first connected all LED’s will flash ON Momentarily.
Verify the Power LED stays ON (GREEN).
Note:
Either V
1
or V
2
can be connected to power for minimal operation. For redundant applications both
inputs must be provided from the same Class 2 source. The power cord should be limited to less than 10
meters in order to ensure optimum performance.
Recommended 24V DC Power Supplies, similar to:
100VAC/240VAC:
N-Tron NTPS-24-1.3, DC 24V/1.3A