background image

(Revised 2010-11-15) 

20 

 

Recommended Wiring Clearance:

 

 

Top:   1 " (2.54 cm)  

 

Front: 4 " (10.16 cm) 

 
Emissions and Safety Approvals:

 

FCC Part 15 Class A CE, UL, FM Class 1 Div 2 Groups A,B,C,D 
Note: Shielded cables must be used to meet emission standards. 
 
DNV/Det Norske Veritas (A-10136)

 

 

Ordering Information

 

 

PN 

 

 

Description 

 

604MFX-ST 

Industrial Ethernet Switch, ST Fiber Connectors, 

608MFX-ST 

MM, 2km 

 
604MFXE-ST-YY 

Industrial Ethernet Switch, ST Fiber Connectors, 

608MFXE-ST-YY 

Singlemode 

 
Where: 

YY = -15, -40, or -80km 

 
URMK 

19” Rack Mount Kit 

 
SDP1 

Din Rail Power Supply 

 

111-220VAC input 

 

[email protected] 

 

 

Warranty

:  Effective January 1, 2008, all N-TRON products carry a 3 year 

limited warranty from the date of purchase. 
 

Contact/Support Information 

N-TRON Corp 
820 S. University Blvd., Suite 4E,  
Mobile, AL 36609 
TEL: (251) 342-2164 
FAX: (251) 342-6353 
Website: 

www.n-tron.com

 

E-mail: 

[email protected]

 

 

Содержание 604MFX-ST

Страница 1: ...Revised 2010 11 15 1 600 Series Industrial Ethernet Switches Hardware Installation Guide...

Страница 2: ...Revised 2010 11 15 2 Industrial Ethernet Switch Installation Guide 604MFX ST 604MFXE ST 15 604MFXE ST 40 604MFXE ST 80 608MFX ST 608MFXE ST 15 608MFXE ST 40 608MFXE ST 80...

Страница 3: ...limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoeve...

Страница 4: ...he warranty See the grounding technique section of this user manual for proper ways to ground the unit WARNING Do not work on equipment or cables during periods of lightning activity WARNING Do not pe...

Страница 5: ...Optic ports The 604 608MFX are managed switches that supports SNMP management software as well as configuration by a CLI Command Line Interface Serial Port Telnet and or Web based browsers The 600 Ser...

Страница 6: ...ts contain a class 1 laser Do not stare into the laser beam fiber optic connector when installing or operating the product Never install or work on electrical equipment or cabling during periods of li...

Страница 7: ...f this product and who possess the relevant qualifications for their work e g Training in or authorization for connecting up grounding or labeling circuits and devices or systems in accordance with cu...

Страница 8: ...Voltage Current for F1 F2 is limited to 24V 100mA 3 Plug the Voltage Input Plug back into the side header All LED s will flash ON Momentarily 4 Tightening torque for the terminal block power plug is 0...

Страница 9: ...n Likewise the TX out port 8 should be connected to the RX in port 7 of the far end station completing the ring The RX in port 8 should be connected to the TX out port 7 on the far end station 608MFX...

Страница 10: ...separate paths Two of the 608MFX s in a ring are connected together via a connection cable with an ITP cable maximum length of 40m and inform each other of their operating states One of the 608MFX un...

Страница 11: ...1 1 1 Cat5E Cat5E Replacing the Standby Master during operation When replacing a standby master during operation the following procedure is necessary to prevent an interruption on the network 1 Remov...

Страница 12: ...ting the 608MFX is in the active mode In other words the Ring master has failed and the standby takes over the data traffic RM Redundancy Manager green LED Status Meaning ON The 604 608MFX is operatin...

Страница 13: ...tate Port Status OFF No Valid Connection to the port Green Valid Connection to the port good link Flashes green once per cycle port switched to standby Flashes green three time per cycle port is disab...

Страница 14: ...return to their defaults as set in the factory This allows you to cancel settings made from the Web based management tools Telnet or the command line configurator serial port or the fault mask If the...

Страница 15: ...EEE 802 1Q Users must configure their networks so that no VLAN packets are sent IEEE 802 1P QOS The 600 Series does support QOS Users should configure their networks such that no packets with a priori...

Страница 16: ...ee Network Management Users guide The pin outs are shown below DSR Pin 6 RTS Pin 7 CTS Pin 8 Pin 9 Pin 1 RXD Pin 2 TXD Pin 3 DTR Pin 4 GND Pin 5 Standby Sync Port 608MFX Only A 9 pin female connector...

Страница 17: ...The following table shows the pin out and the connections for both types of cable PC Port 25 Pin 9 Pin 604 608MFX Female Female 9 Pin Female Signal Name Pin Pin Pin Signal Name TXD 2 3 2 RXD RXD 3 2...

Страница 18: ...rity 7 Verify that cabling is Category 5 or higher for 100Mbit TX Operation 62 5 125 m 1300nm for 100 Mbit FX Operation 8 Verify TX port 7 is connected to RX port 8 and vice versa 9 Verify that only o...

Страница 19: ...erature 40 C to 80 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 6 500 ft Shock and Vibration Shock 200g 10ms Vibration 1g 10 500Hz Seismic 20g 5 200Hz 15s 3 axis Reliability MT...

Страница 20: ...rnet Switch ST Fiber Connectors 608MFX ST MM 2km 604MFXE ST YY Industrial Ethernet Switch ST Fiber Connectors 608MFXE ST YY Singlemode Where YY 15 40 or 80km URMK 19 Rack Mount Kit SDP1 Din Rail Power...

Страница 21: ...kaged appropriately for safe shipment Responsibility for loss or damage does not transfer to N TRON until the returned item is received by N TRON The repaired or replaced item will be shipped to the c...

Страница 22: ...SS OF BUSINESS LOSS OF INFORMATION OR DATA OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN I...

Отзывы: