Rev 041008 

16 

N-TRON Limited Warranty 

 

N-TRON,  Corp.  warrants  to  the  end  user  that  this  hardware  product  will  be  free  from  defects  in  workmanship  and  materials, 
under  normal  use  and  service,  for  the  applicable  warranty  period  from  the  date  of  purchase  from  N-TRON  or  its  authorized 
reseller.    If  a  product  does  not  operate  as  warranted  during  the  applicable  warranty  period,  N-TRON  shall,  at  its  option  and 
expense, repair the defective product or part, deliver to customer an equivalent product or part to replace the defective item, or 
refund to customer the purchase price paid for the defective product.  All products that are replaced will become the property of 
N-TRON.  Replacement products may be new or reconditioned.  Any replaced or repaired product or part has a ninety (90) day 
warranty or the remainder of the initial warranty period, whichever is longer.  N-TRON shall not be responsible for any custom 
software  or  firmware,  configuration  information,  or  memory  data  of  customer  contained  in,  stored  on,  or  integrated  with  any 
products returned to N-TRON pursuant to any warranty. 
 
OBTAINING WARRANTY SERVICE: Customer must contact N-TRON within the applicable warranty period to obtain 
warranty service authorization.  Dated proof of purchase from N-TRON or its authorized reseller may be required.  Products 
returned to N-TRON must be pre-authorized by N-TRON with a Return Material Authorization (RMA) number marked on the 
outside of the package, and sent prepaid and packaged appropriately for safe shipment. Responsibility for loss or damage does not 
transfer to N-TRON until the returned item is received by N-TRON.  The repaired or replaced item will be shipped to the 
customer, at N-TRON’s expense, not later than thirty (30) days after N-TRON receives the product.  N-TRON shall not be 
responsible for any software, firmware, information, or memory data of customer contained in, stored on, or integrated with any 
products returned to N-TRON for repair, whether under warranty or not. 
 
ADVANCE REPLACEMENT OPTION:  Upon registration, this product qualifies for advance replacement.  A replacement 
product will be shipped within three (3) days after verification by N-TRON that the product is considered defective.  The 
shipment of advance replacement products is subject to local legal requirements and may not be available in all locations.  When 
an advance replacement is provided and customer fails to return the original product to N-TRON within fifteen (15) days after 
shipment of the replacement, N-TRON will charge customer for the replacement product, at list price. 
 
WARRANTIES EXCLUSIVE: IF AN N-TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, 
CUSTOMER'S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR, REPLACEMENT, OR 
REFUND OF THE PURCHASE PRICE PAID, AT N-TRON'S OPTION. TO THE FULL EXTENT ALLOWED BY LAW, THE 
FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, 
TERMS, OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR 
OTHERWISE, INCLUDING WARRANTIES, TERMS, OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A 
PARTICULAR PURPOSE, SATISFACTORY QUALITY, CORRESPONDENCE WITH DESCRIPTION, AND NON-
INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY DISCLAIMED. N-TRON NEITHER ASSUMES NOR AUTHORIZES 
ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, 
INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. N-TRON SHALL NOT BE LIABLE UNDER THIS 
WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION 
IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER'S OR ANY THIRD PERSON'S MISUSE, 
NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO OPEN, REPAIR OR MODIFY 
THE PRODUCT, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, 
LIGHTNING, POWER CUTS OR OUTAGES, OTHER HAZARDS, OR ACTS OF GOD.  
 
LIMITATION OF LIABILITY: TO THE FULL EXTENT ALLOWED BY LAW, N-TRON ALSO EXCLUDES FOR ITSELF 
AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), 
FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR 
LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATA, OR OTHER FINANCIAL 
LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, 
PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF N-TRON OR ITS AUTHORIZED 
RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS LIABILITY TO 
REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT N-TRON'S OPTION. THIS DISCLAIMER 
OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF 
ITS ESSENTIAL PURPOSE.  
 
DISCLAIMER: Some countries, states, or provinces do not allow the exclusion or limitation of implied warranties or the 
limitation of incidental or consequential damages for certain products supplied to consumers, or the limitation of liability for 
personal injury, so the above limitations and exclusions may be limited in their application to you. When the implied warranties 
are not allowed to be excluded in their entirety, they will be limited to the duration of the applicable written warranty. This 
warranty gives you specific legal rights which may vary depending on local law.  
 
GOVERNING LAW: This Limited Warranty shall be governed by the laws of the State of Alabama, U.S.A. 

Содержание 400 Series

Страница 1: ...Rev 041008 1 400 Series Industrial Ethernet Switches Installation Guide...

Страница 2: ...Rev 041008 2 Industrial Ethernet Switch Installation Guide 405TX 405FX SC 405FX ST 405FXE SC YY 405FXE ST YY Where YY 15 40 or 80...

Страница 3: ...ited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever in...

Страница 4: ...s of lightning activity WARNING Do not perform any services on the unit unless qualified to do so WARNING Do not block the air vents WARNING Observe proper DC Voltage polarity when installing power in...

Страница 5: ...05FXE is a 5 port unmanaged switch that is similar to the 405FX but with extended range The N TRON 405FXE utilizes a singlemode fiber transceiver that is capable of 15 Kilometers of 100 Mb communicati...

Страница 6: ...WARNING The 405FXE unit contains a Class 1 Laser Do not stare into the laser beam fiber optic connector when installing or operating the product Never install or work on electrical equipment or cabli...

Страница 7: ...lf Duplex Remove jumper In order to verify the jumper settings have been set correctly for units which have the N View option turned on you should install N ViewOPC Server software on a PC connected t...

Страница 8: ...rom the 35mm industrial DIN Rail apply downward force to the unit until it disengages from the bottom of the unit from the DIN Rail Then rotate the unit approximately 15 upward and towards you to comp...

Страница 9: ...XE Only ACT Activity LED for Fiber Optic Port 405FX FXE only X RJ45 Crossover Uplink Port 405TX Only RJ45 Ports Auto sensing 10 100BaseT Connections Red LED indicates controller error Green LED lights...

Страница 10: ...C Power Cables into the Plug s observing polarity Plug the Voltage Input Plug s back into the side header Tightening torque for the terminal block power plug is 0 22 Nm 0 162 Pound Foot All LED s will...

Страница 11: ...can run a drain wire lug from any of the Din Rail screws or empty PEM nuts on the enclosure When using an unused PEM nut to connect a ground lug via a machine screw care should be taken to limit the...

Страница 12: ...Rev 041008 12 RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications...

Страница 13: ...port to port connection on the same switch i e loop is an illegal operation and will create a broadcast storm which will crash the network TROUBLESHOOTING 1 Make sure the Power LED is ON 2 Make sure...

Страница 14: ...ing Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable 100BaseFX Multimode 50 62 5 125 m Fiber Singlemode 7 10 125 m Fiber Fiber...

Страница 15: ...Zone 2 Group IIC T4A EMI EN55022 Class A FCC Part 15 Class A EMS EN55024 1998 EN61000 4 2 1995 EN61000 4 3 1997 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 GOST R Certified Warranty Effective J...

Страница 16: ...IES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S O...

Отзывы: