N-Tron 400 Series Скачать руководство пользователя страница 13

Rev 041008 

13 

CONNECTING THE UNIT 
 
For 405FX & 405FXE units, remove the dust cap from the fiber optic connectors and connect the fiber 
optic cables.  The TX port on the 405FX should be connected to the RX port of the far end station.  The 
RX port on the 405FX should be connected to the TX port of the far end station. 
 
For 10/100 Base-TX ports, plug a Category 5 twisted pair cable into the RJ45 connector.  Connect the 
other  end  to  the  far  end  station.    Verify  that  the  LNK  LED’s  are  ON  once  the  connection  has  been 
completed.    For  Switch  to  Switch  or  Switch  to  Repeater  connections,  use  the  X-port  and  a  standard 
Category 5 cable.  To connect any other port (other than the X-Port) to another Switch or Repeater, use a 
standard Category 5 crossover cable.   
 
Warning:  Creating a port to port connection on the same switch (i.e. loop) is an illegal operation and 
will create a broadcast storm which will crash the network! 

 

TROUBLESHOOTING 

1.

 

Make sure the   (Power LED) is ON. 

2.

 

Make sure the 

!

 (Error LED) remains OFF 3 seconds after initial power up. 

3.

 

Verify that Link LED’s are ON for connected ports. 

4.

 

Verify straight through cabling used between stations.   

5.

 

Verify crossover cabling used between switches or repeaters (non X-Port only). 

6.

 

Verify that cabling is Category 5 for 100Mbit Operation. 

7.

 

Verify TX is connected to far end RX and vise versa    (405FX/FXE only). 

 
SUPPORT 

Contact N-TRON Corp. at: 
TEL: 251-342-2164 
FAX: 251-342-6353 

www.n-tron.com

 

[email protected]

 

 

FCC STATEMENT 
 
This product complies with Part 15 of the FCC-A Rules. 
Operation is subject to the following conditions: 
(1)

 

This device may not cause harmful Interference 

(2)

 

This device must accept any interference received, including interference that may cause undesired 
operation. 

 

    

     

     

  

 

Содержание 400 Series

Страница 1: ...Rev 041008 1 400 Series Industrial Ethernet Switches Installation Guide...

Страница 2: ...Rev 041008 2 Industrial Ethernet Switch Installation Guide 405TX 405FX SC 405FX ST 405FXE SC YY 405FXE ST YY Where YY 15 40 or 80...

Страница 3: ...ited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever in...

Страница 4: ...s of lightning activity WARNING Do not perform any services on the unit unless qualified to do so WARNING Do not block the air vents WARNING Observe proper DC Voltage polarity when installing power in...

Страница 5: ...05FXE is a 5 port unmanaged switch that is similar to the 405FX but with extended range The N TRON 405FXE utilizes a singlemode fiber transceiver that is capable of 15 Kilometers of 100 Mb communicati...

Страница 6: ...WARNING The 405FXE unit contains a Class 1 Laser Do not stare into the laser beam fiber optic connector when installing or operating the product Never install or work on electrical equipment or cabli...

Страница 7: ...lf Duplex Remove jumper In order to verify the jumper settings have been set correctly for units which have the N View option turned on you should install N ViewOPC Server software on a PC connected t...

Страница 8: ...rom the 35mm industrial DIN Rail apply downward force to the unit until it disengages from the bottom of the unit from the DIN Rail Then rotate the unit approximately 15 upward and towards you to comp...

Страница 9: ...XE Only ACT Activity LED for Fiber Optic Port 405FX FXE only X RJ45 Crossover Uplink Port 405TX Only RJ45 Ports Auto sensing 10 100BaseT Connections Red LED indicates controller error Green LED lights...

Страница 10: ...C Power Cables into the Plug s observing polarity Plug the Voltage Input Plug s back into the side header Tightening torque for the terminal block power plug is 0 22 Nm 0 162 Pound Foot All LED s will...

Страница 11: ...can run a drain wire lug from any of the Din Rail screws or empty PEM nuts on the enclosure When using an unused PEM nut to connect a ground lug via a machine screw care should be taken to limit the...

Страница 12: ...Rev 041008 12 RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications...

Страница 13: ...port to port connection on the same switch i e loop is an illegal operation and will create a broadcast storm which will crash the network TROUBLESHOOTING 1 Make sure the Power LED is ON 2 Make sure...

Страница 14: ...ing Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable 100BaseFX Multimode 50 62 5 125 m Fiber Singlemode 7 10 125 m Fiber Fiber...

Страница 15: ...Zone 2 Group IIC T4A EMI EN55022 Class A FCC Part 15 Class A EMS EN55024 1998 EN61000 4 2 1995 EN61000 4 3 1997 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 GOST R Certified Warranty Effective J...

Страница 16: ...IES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S O...

Отзывы: