
(Revised 2010-7-30)
7
ATEX Installation Requirements
1.
The conductor size of the phase conductor must be in the range of 0.05-2.08 mm2.
2.
Field wiring must be suitable for a minimum of 110°C.
3.
Ethernet Switches are intended for mounting in an IP54 enclosure in a pollution degree 2
environ
ment.
4.
Temperature testing of the Ethernet Switches was conducted on the switch itself in an 85°C air-
circulating oven and resulted in a Temperature Code of T4. However, end-product temperature testing
shall be considered.
5.
The end user shall provide bonding means as necessary. All bonding equipment (components) shall be
evaluated according to EN 60079-15:2005 and covered by a component certificate for the actual use.
When installing bonding components that will pass through an enclosure wall, they must have a
minimum of IP54 rating equal to the enclosure. All electrical clearances must be maintained per the
manufacturer‟s instructions of the bonding component or per EN 60079-15:2005.
6.
Ethernet Switch requires protection against transients. The end-product shall provide a suitable form of
protection that removes the risk of or limits transients to no more than 42V.
Содержание 308FX2
Страница 6: ...Revised 2010 7 30 6...