background image

(Revised 2011-03-14) 

39 

 

N-TRON Limited Warranty

 

 

N-TRON, Corp. warrants to the end user that this hardware product will be free from defects in workmanship and materials, under normal use 
and service, for the applicable warranty period from the date of purchase from N-TRON or its authorized reseller.  If a product does not operate 
as  warranted  during  the  applicable  warranty  period,  N-TRON  shall,  at  its  option  and  expense,  repair  the  defective  product  or  part,  deliver  to 
customer an equivalent product or part to replace the defective item, or refund to customer the purchase price paid for the defective product.  All 
products that are replaced will become the property of N-TRON.  Replacement products may be new or reconditioned.  Any replaced or repaired 
product  or  part  has  a  ninety  (90)  day  warranty  or  the  remainder  of  the  initial  warranty  period,  whichever  is  longer.    N-TRON  shall  not  be 
responsible for any custom software or firmware, configuration information, or memory data of customer contained in, stored on, or integrated 
with any products returned to N-TRON pursuant to any warranty. 
 
OBTAINING  WARRANTY  SERVICE:  Customer  must  contact  N-TRON  within  the  applicable  warranty  period  to  obtain  warranty  service 
authorization.  Dated proof of purchase from N-TRON or its authorized reseller may be required.  Products returned to N-TRON must be pre-
authorized  by  N-TRON  with  a  Return  Material  Authorization  (RMA)  number  marked  on  the  outside  of  the  package,  and  sent  prepaid  and 
packaged appropriately for safe shipment. Responsibility for loss or damage does not transfer to N-TRON until the returned item is received by 
N-TRON.  The repaired or replaced item will be shipped to the customer, at N-TRON’s expense, not later than thirty (30) days after N-TRON 
receives  the  product.    N-TRON  shall  not  be  responsible  for  any  software,  firmware,  information,  or  memory  date  of  customer  contained  in, 
stored on, or integrated with any products returned to N-TRON for repair, whether under warranty or not. 
 
ADVANCE  REPLACEMENT  OPTION:    Upon  registration,  this  product  qualifies  for  advance  replacement.    A  replacement  product  will  be 
shipped  within  three  (3)  days  after  verification  by  N-TRON  that  the  product  is  considered  defective.    The  shipment  of  advance  replacement 
products  is  subject  to  local  legal  requirements  and  may  not  be  available  in  all  locations.    When  an  advance  replacement  is  provided  and 
customer  fails  to  return  the  original  product  to  N-TRON  within  fifteen  (15)  days  after  shipment  of  the  replacement,  N-TRON  will  charge 
customer for the replacement product, at list price. 
 
WARRANTIES  EXCLUSIVE:  IF  AN  N-TRON  PRODUCT  DOES  NOT  OPERATE  AS  WARRANTED  ABOVE,  CUSTOMER'S  SOLE 
REMEDY  FOR  BREACH  OF  THAT  WARRANTY  SHALL  BE  REPAIR,  REPLACEMENT,  OR  REFUND  OF  THE  PURCHASE  PRICE 
PAID,  AT  N-TRON'S  OPTION.  TO  THE  FULL  EXTENT  ALLOWED  BY  LAW,  THE  FOREGOING  WARRANTIES  AND  REMEDIES 
ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, TERMS, OR CONDITIONS, EXPRESS OR IMPLIED, EITHER 
IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES, TERMS, OR CONDITIONS OF 
MERCHANTABILITY,  FITNESS  FOR  A  PARTICULAR  PURPOSE,  SATISFACTORY  QUALITY,  CORRESPONDENCE  WITH 
DESCRIPTION, AND NON-INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY DISCLAIMED. N-TRON NEITHER ASSUMES NOR 
AUTHORIZES  ANY  OTHER  PERSON  TO  ASSUME  FOR  IT  ANY  OTHER  LIABILITY  IN  CONNECTION  WITH  THE  SALE, 
INSTALLATION,  MAINTENANCE  OR  USE  OF  ITS  PRODUCTS.  N-TRON  SHALL  NOT  BE  LIABLE  UNDER  THIS  WARRANTY  IF 
ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT 
EXIST  OR  WAS  CAUSED  BY  CUSTOMER'S  OR  ANY  THIRD  PERSON'S  MISUSE,  NEGLECT,  IMPROPER  INSTALLATION  OR 
TESTING, UNAUTHORIZED ATTEMPTS TO OPEN, REPAIR OR MODIFY THE PRODUCT, OR ANY OTHER CAUSE BEYOND THE 
RANGE  OF  THE  INTENDED  USE,  OR  BY  ACCIDENT,  FIRE,  LIGHTNING,  POWER  CUTS  OR  OUTAGES,  OTHER  HAZARDS,  OR 
ACTS OF GOD.  
 
LIMITATION  OF  LIABILITY:  TO  THE  FULL  EXTENT  ALLOWED  BY  LAW,  N-TRON  ALSO  EXCLUDES  FOR  ITSELF  AND  ITS 
SUPPLIERS  ANY  LIABILITY,  WHETHER  BASED  IN  CONTRACT  OR  TORT  (INCLUDING  NEGLIGENCE),  FOR  INCIDENTAL, 
CONSEQUENTIAL,  INDIRECT,  SPECIAL,  OR  PUNITIVE  DAMAGES  OF  ANY  KIND,  OR  FOR  LOSS  OF  REVENUE  OR  PROFITS, 
LOSS OF BUSINESS, LOSS OF INFORMATION OR DATA, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION 
WITH  THE  SALE,  INSTALLATION,  MAINTENANCE,  USE,  PERFORMANCE,  FAILURE,  OR  INTERRUPTION  OF  ITS  PRODUCTS, 
EVEN  IF  N-TRON  OR  ITS  AUTHORIZED  RESELLER  HAS  BEEN  ADVISED  OF  THE  POSSIBILITY  OF  SUCH  DAMAGES,  AND 
LIMITS ITS LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT N-TRON'S OPTION. THIS 
DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED  HEREIN SHALL FAIL OF 
ITS ESSENTIAL PURPOSE.  
 
DISCLAIMER: Some countries, states, or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental 
or consequential damages  for certain products supplied to consumers or the limitation of liability for personal injury, so the above limitations 
and exclusions may be limited in their application to you. When the implied warranties are not allowed to be excluded in their entirety, they will 
be limited to the duration of the applicable written warranty. This warranty gives you specific legal rights which may vary depending on local 
law.  
 
GOVERNING LAW: This Limited Warranty shall be governed by the laws of the State of Delaware, U.S.A.

 

 

Содержание 102MC

Страница 1: ... Revised 2011 04 15 1 100 Series Media Converter Industrial Ethernet Switches User Manual Installation Guide ...

Страница 2: ...edia Converter and Ethernet Switch Installation Guide 102MC XX 105TX 106FX2 110FX2 XX YY 102MCE XX YY 105TX SL 108TX 111FX3 XX YY 104TX 105FX XX 108TX HV 112FX4 XX YY 105FXE XX YY 114FX6 XX YY 116TX Where XX ST or SC and YY 15 40 or 80 ...

Страница 3: ...tion contained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits a...

Страница 4: ...hing else to the unit Units not properly grounded may result in a safety risk and could be hazardous and may void the warranty See the grounding technique section of this user manual for proper ways to ground the unit WARNING Do not operate the equipment in a manner not specified by this manual ENVIRONMENTAL SAFETY WARNINGS WARNING Disconnect the power and allow to cool 5 minutes before touching E...

Страница 5: ... field installed conductors For the 116TX Use 105 C rated copper wire 0 22Nm 2 inch lbs tightening torque for field installed conductors 6 WARNING Install only in accordance with Local National Codes of Authorities Having Jurisdiction 7 Class I Div 2 Installations require that power connections must be current limited at the power source with an in line fuse rated at 0 5A 8 Class I Div 2 installat...

Страница 6: ...X models and up to 80 Kilometers for the FXE models without the use of repeaters The 110FX2 FXE2 has 8 10 100BaseTX RJ 45 auto sensing ports and 2 100BaseFX ports with ST or SC connectors capable of 2 Kilometers of 100 Mb communications for the FX models and up to 80 Kilometers for the FXE models without the use of repeaters The 111FX3 FXE3 has 8 10 100BaseTX RJ 45 auto sensing ports and 3 100Base...

Страница 7: ...and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth INSTALLATION Read the following warning before beginning the installation WARNING Never install or work on electrical equipment or cabling during periods of lightning activity Never connect or disconnect power when hazardous gasses are present LASER SAFETY MCE and FXE models only 4...

Страница 8: ...at the bottom of the unit and apply downward force on the clip until it disengages from the bottom of the unit from the DIN rail Rotate the bottom of the unit towards you and up at an approximate 15 upward angle to completely remove the unit To install the metal clip units to 35mm industrial DIN rail place the top edge of the included mounting bracket on the back of the unit against the DIN rail a...

Страница 9: ... Our Universal Rack Mount Kit P N URMK may be used to mount the 100 Series enclosures to standard 19 racks and our Panel Mount Assembly P N 1000 PM may be used to mount the metal clip versions of the 100 Series enclosures to a panel or any other flat surface NOTE the 1000 PM will only work with the factory installed MDR metal clip options and it is not acceptable for the 116TX units ...

Страница 10: ...om Top to Bottom SPD Speed LED LNK ACT Link Activity LED RJ45 Ports Auto sensing 10 100BaseT Connection Green LED lights when Power is connected NOTE The top LED indicates Link Activity LNK ACT and the lower LED indicates Speed SPD status ...

Страница 11: ...ption ON Power is Applied OFF Power is OFF LNK ACT ON Link established no Activity on cable BLINKING Link established Activity on cable OFF No link activity on cable SPD ON LINK is 100Mbps OFF Link is 10Mbs APPLYING POWER 102MC 104TX 105TX 105FX 106FX2 108TX and 116TX Power Connector Top View ...

Страница 12: ... Note Either V1 or V2 can be connected to power for minimal operation For redundant power operation V1 and V2 plugs must be connected to separate DC Voltage sources Use wire sizes of 16 28 gauge The power cord should be limited to less than 10 meters in order to ensure optimum performance Recommended 24V DC Power Supplies similar to 100 240VAC N Tron NTPS 24 1 3 DC 24V 1 3 105TX SL Top View Unscre...

Страница 13: ...vided on the back face of the enclosure In the event the provided grounding screw has been lost care should be taken to limit the penetration of the outer skin by less than 1 4 Failure to do so may cause irreversible damage to the internal components of the switch Note Ensure the power supply is grounded properly before applying power to the grounded switch This may be verified by using a voltmete...

Страница 14: ...o use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration for your Cat5 cable specifications 105TX SL DRAIN WIRE WITH LUG CONNECTING SWITCH CHASSIS TO KNOWN GOOD GROUNDING POINT METALLIC DIN RAIL CLIP DRAIN WIRE WITH LUG CONNECTING SWITCH CHASSIS TO KNOWN GOOD GROUNDING POI...

Страница 15: ...nd station Verify that the LNK LED s are ON once the connection has been completed To connect any other port to another Switch or Repeater use a standard Cat5 straight through or crossover cable Warning Creating a port to port connection on the same switch i e loop is an illegal operation and will create a broadcast storm which will crash the network TROUBLESHOOTING 1 Make sure the Power LED is ON...

Страница 16: ...radio communications Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may n...

Страница 17: ...Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Fiber Singlemode 7 10 125µm Fiber Fiber Transceiver Characteristics Fiber Length 2km 15km 40km 80km TX Power Min 19dBm 15dBm 5dBm 5dBm RX Sensitivity Max 31dBm 31dBm 34dBm 34dBm Wavelength 1310nm 1310nm 1310nm 1550nm Multimode Singlemode Connec...

Страница 18: ... Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances GOST R Certified ...

Страница 19: ...4VDC Input Ripple Less than 100 mV Input Wire Size 16 28 AWG Environmental Operating Temperature 40 C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable Connectors 10 100BaseT RJ45 UTP Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Warranty Effective J...

Страница 20: ... Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances GOST R Certified ...

Страница 21: ...ut Ripple Less than 100 mV Input Wire Size 12 24 AWG Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat3 Cable 100BaseT Cat5 Cable Connectors 10 100BaseT Five 5 RJ45 UTP Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Warranty Effective Janu...

Страница 22: ...d D Hazardous Locations or Nonhazardous Locations only EMI ANSI C63 4 FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 4 Class A Emissions EN55024 Immunity EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 SURGE EN61000 4 6 RF EN61000 4 8 PFMF EN61000 4 11 VDI GOST R Certified ...

Страница 23: ...ting Temperature 40 C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseTX Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Singlemode 7 10 125µm Connectors 10 100BaseTX Four 4 RJ 45 TX Ports 100BaseFX Two 2 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16...

Страница 24: ...ardous Locations or Nonhazardous Locations only EMI IEC61000 6 2 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances EN61000 4 11 Voltage Dips and Interruptions GOST R Certified ...

Страница 25: ...ms max 24VDC Input Ripple Less than 100 mV Input Wire Size 16 28 AWG Environmental Operating Temperature 40 C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable Connectors 10 100BaseT Eight 8 RJ45 UTP Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Warr...

Страница 26: ...ons or Nonhazardous Locations only The high voltage model is TÜV approved GS per EN 60950 1 EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances GOST R Certified HV Model Only ...

Страница 27: ...midity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Fiber Singlemode 7 10 125µm Fiber Fiber Transceiver Characteristics Fiber Length 2km 15km 40km 80km TX Power Min 19dBm 15dBm 5dBm 5dBm RX Sensitivity Max 31dBm 31dBm 34dBm 34dBm Wavelength 1310nm 1310nm 1310nm 1550nm Multimode Singlemode Connecto...

Страница 28: ... A B C and D Hazardous Locations or Nonhazardous Locations only EMI EN 61000 6 4 EN 55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN 61000 6 2 IEC 61000 4 2 ESD IEC 61000 4 3 RS IEC 61000 4 4 EFT IEC 61000 4 5 Surge IEC 61000 4 6 Conducted Disturbances GOST R Certified ...

Страница 29: ...C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseTX Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Singlemode 7 10 125µm Connectors 10 100BaseTX Eight 8 RJ 45 TX Ports 100BaseFX Two 2 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effect...

Страница 30: ...nd D Hazardous Locations or Nonhazardous Locations only EMI FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 4 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 Magnetic Field EN61000 4 11 Voltage Dips and Interruptions GOST R Certified ...

Страница 31: ...C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseTX Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Singlemode 7 10 125µm Connectors 10 100BaseTX Eight 8 RJ 45 TX Ports 100BaseFX Two 2 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effect...

Страница 32: ...nd D Hazardous Locations or Nonhazardous Locations only EMI FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 4 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 Magnetic Field EN61000 4 11 Voltage Dips and Interruptions GOST R Certified ...

Страница 33: ...C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseTX Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Singlemode 7 10 125µm Connectors 10 100BaseTX Eight 8 RJ 45 TX Ports 100BaseFX Four 4 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effec...

Страница 34: ...nd D Hazardous Locations or Nonhazardous Locations only EMI FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 4 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 Magnetic Field EN61000 4 11 Voltage Dips and Interruptions GOST R Certified ...

Страница 35: ...C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseTX Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Singlemode 7 10 125µm Connectors 10 100BaseTX Eight 8 RJ 45 TX Ports 100BaseFX Four 4 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effec...

Страница 36: ...nd D Hazardous Locations or Nonhazardous Locations only EMI FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 4 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 Magnetic Field EN61000 4 11 Voltage Dips and Interruptions GOST R Certified ...

Страница 37: ... Environmental Surrounding Air Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat3 Cable 100BaseTX Cat5 Cable Connectors 10 100BaseTX Sixteen 16 RJ 45 TX Ports Recommended Minimum Wiring Clearance Top 1 2 6 cm Front 2 5 1 cm Warranty Effective January 1 2008 all N TRON products carry a 3 y...

Страница 38: ... Hazardous Locations or Nonhazardous Locations only EMI ANSI C63 4 FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 4 Class A Emissions EN 55024 Immunity EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 PFMF EN61000 4 11 VDI GOST R Certified ...

Страница 39: ...RRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPE...

Отзывы: