N-Tron 100-POE-SPL Скачать руководство пользователя страница 7

(Revised 2010-11-15) 

DIN-Rail Mounting

 

 

Install the unit in a standard DIN rail.  Recess the unit to allow at least 2” of horizontal clearance for CAT5e 
cable bend radius. 

 

                               

 

 
    To install the unit to 35mm industrial DIN rail, 
place  the  top  edge  of  the  included  mounting 
bracket  on  the  back  of  the  unit  against  the  DIN 
rail at a 15° angle as shown. Rotate the bottom of 
the  unit  to  the  back  (away  from  you)  until  it 
snaps into place. 

    To  remove  the  unit  from  the  35mm  industrial 
DIN  rail,  pull  forward  on  the  unit  until  it 
disengages  from  the  bottom  of  the  DIN  rail. 
Rotate the bottom of the unit towards you and up 
at  an  approximate  15°  upward  angle  to 
completely remove the unit. 
 

 

 

 

 

 

URMK   

 

 

 

 

 

1000-PM 

 

   

Most N-Tron™ products are designed to be mounted on industry standard 35mm DIN rail. However, DIN rail 

mounting may not be suitable for all applications. Our Universal Rack Mount Kit (P/N: URMK) may be used to 
mount the 100-POE-SPL-XX enclosures to standard 19" racks, and our Panel Mount Assembly (P/N: 1000-PM) 
may be used to mount the 100-POE-SPL-XX enclosures to a panel or any other flat surface. 

 
 

Содержание 100-POE-SPL

Страница 1: ...Revised 2010 11 15 1 100 POE SPL Industrial Power Extractor User Manual Installation Guide...

Страница 2: ...tractor Installation Guide 100 POE SPL XX Unmanaged Industrial PoE Power Extractor Where XX is 12 for 12VDC output voltage option 24 for 24VDC output voltage option 48 for 48VDC output voltage option...

Страница 3: ...ion contained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchan...

Страница 4: ...TRON Corp the protection provided by the equipment may be impaired WARNING Do not perform any services on the unit unless qualified to do so Do not substitute unauthorized parts or make unauthorized m...

Страница 5: ...Cat5e cable connected to a PoE sourcing device The 100 POE SPL allows legacy devices which are not PoE capable to be deployed without the need to provide a dedicated power supply The 100 POE SPL can b...

Страница 6: ...emove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth INSTALLATION Read the following warning...

Страница 7: ...unit from the 35mm industrial DIN rail pull forward on the unit until it disengages from the bottom of the DIN rail Rotate the bottom of the unit towards you and up at an approximate 15 upward angle...

Страница 8: ...48VDC connector Model dependent Green LED lights when Power is present POE IN RJ45 connector for data and PoE in DATA OUT RJ45 connector for data only out LEDs The table below describes the operating...

Страница 9: ...ource device into the POE IN port Verify the Power LED stays ON GREEN Note Either V1 or V2 can be connected to power for minimal operation For redundant power operation V1 and V2 plugs must be connect...

Страница 10: ...gative output terminal and the chassis grounding point of the switch As an alternative grounding method both V legs of the power input connector are connected to chassis internally on the PCB Connecti...

Страница 11: ...voltage to 12 24 48VDC for the legacy end device Warning The 100 POE SPL XX is not a switch and will not actively boost the Ethernet signals So the total max segment length is a combined 100meters Mea...

Страница 12: ...cause harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian...

Страница 13: ...DC Max Full Load Output Wire Size 16 28 AWG Max Capacitive Load 400uF Assuming 50ohm DC Load Max Inrush 700mA 50ms 24VDC Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85...

Страница 14: ...2 Groups A B C D hazardous or non hazardous locations temperature code of T4 EMI EN61000 6 4 EN55022 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN6...

Страница 15: ...RANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON...

Отзывы: