N.A.T. NAMC-ZYNQ-FMC Скачать руководство пользователя страница 3

 
NAMC-ZYNQ-FMC – Board Support Package Manual 
 
 
 

 

 

Version 1.0 

© N.A.T. GmbH 

III 

Disclaimer 

 

The following documentation, compiled by N.A.T GmbH (henceforth called N.A.T), repre-
sents the current status of the product´s development. The documentation is updated on 
a regular basis. Any changes which might ensue, including those necessitated by updated 
specifications, are considered in the latest version of this documentation. N.A.T is under 
no obligation to notify any person, organization, or institution of such changes or to make 
these changes public in any other way. 

We  must  caution  you,  that  this  publication  could  include  technical  inaccuracies  or 
typographical errors. 

N.A.T  offers  no  warranty,  either  expressed  or  implied,  for  the  contents  of  this 
documentation  or  for  the  product  described  therein,  including  but  not  limited  to  the 
warranties of merchantability or the fitness of the product for any specific purpose.  

In  no  event  will  N.A.T  be  liable  for  any  loss  of  data  or  for  errors  in  data  utilization  or 
processing  resulting  from  the  use  of  this  product  or  the  documentation.  In  particular, 
N.A.T will not be responsible for any direct or indirect damages (including lost profits, lost 
savings, delays or interruptions in the flow of business activities, including but not limited 
to, special, incidental, consequential, or other similar damages) arising out of the use of 
or  inability  to  use  this  product  or  the  associated  documentation,  even  if  N.A.T  or  any 
authorized N.A.T representative has been advised of the possibility of such damages. 

The use of registered names, trademarks, etc. in this publication does not imply, even in 
the  absence  of  a  specific  statement,  that  such  names  are  exempt  from  the  relevant 
protective  laws  and  regulations  (patent  laws,  trade  mark  laws,  etc.)  and  therefore  free 
for  general  use.  In  no  case  does  N.A.T  guarantee  that  the  information  given  in  this 
documentation is free of such third-party rights. 

Neither this documentation nor any part thereof may be copied, translated, or reduced to 
any  electronic  medium  or  machine  form  without  the  prior  written  consent  from  N.A.T 
GmbH. 
This  product  (and  the  associated  documentation)  is  governed  by  the  N.A.T  General 
Conditions and Terms of Delivery and Payment. 

 

Содержание NAMC-ZYNQ-FMC

Страница 1: ...NAMC ZYNQ FMC Board Support Package Manual NAMC ZYNQ FMC FMC AMC Module Board Support Package Manual V1 1...

Страница 2: ...NAMC ZYNQ FMC Board Support Package Manual Version 1 0 N A T GmbH II N A T GmbH Konrad Zuse Platz 9 53227 Bonn Oberkassel Phone 49 228 96 58 64 0 Fax 49 228 96 58 64 10 Internet http www nateurope com...

Страница 3: ...ng resulting from the use of this product or the documentation In particular N A T will not be responsible for any direct or indirect damages including lost profits lost savings delays or interruption...

Страница 4: ...ACKAGE DESCRIPTION 7 1 1 1 INTRODUCTION 7 1 2 PREREQUISITE FOR USING THE BSP 7 1 3 BSP STRUCTURE 7 1 4 VIVADO REFERENCE DESIGN 8 1 5 INSTALLING THE BSP 9 1 6 BUILDING A BOOT IMAGE FOR ZYNQ 10 1 7 PROG...

Страница 5: ...NAMC ZYNQ FMC Board Support Package Manual Version 1 0 N A T GmbH V List of Tables Table 1 BSP folder structure 8 Table 2 Makefile description 12...

Страница 6: ...on 11 Figure 6 Kernel selection 11 Figure 7 TeraTerm Serial Port Setup 13 Figure 8 MMC Boot Output 13 Figure 9 FRU wizard 14 Conventions If not otherwise specified addresses and memory maps are writte...

Страница 7: ...ionality such as standard communication interfaces Common information about the Petalinux build system can be found at UG1144 Petalinux Tools Documentation Reference Guide 2 or at Xilinx wiki http www...

Страница 8: ...Vivado reference design The BSP has a folder vivado witch contains the reference design for the ZYNQ FPGA that customers may use as a template for developing further logic on top of that The design wa...

Страница 9: ...x build system 1 5 Installing the BSP With having both Xilinx Vivado and Petalinux tools installed the next step is to install the BSP sources and set up several paths First you have to copy the main...

Страница 10: ...n the project folder later during the build system configuration The link gets created using the makefile make setup links NOTE Depending on the owner of the petalinux installation it may be the case...

Страница 11: ...mponents configuration Figure 5 U boot selection Figure 6 Kernel selection This is the only necessary configuration you need to do to build the reference design as all other configuration is preconfig...

Страница 12: ...ges it to a single binary make package Packages FSBL bitstream and u boot BOOT bin and image ub are stored at bsp make patch fsbl Patches FSBL sources as they are overwritten each time a new hardware...

Страница 13: ...ure 7 TeraTerm Serial Port Setup When inserting the AMC with connected USB cable into an operational MicroTCA chassis you should see the following output ensuring being connected to the correct COM po...

Страница 14: ...C RET n Generated 188 bytes binary data buf 0x3e12 len 256 01 00 00 01 00 08 00 f6 01 07 00 00 00 00 ca 4e 2e 41 2e 54 20 47 6d 62 48 cb 4e 2e 41 2e 54 20 46 4d 43 30 31 ca 30 30 30 30 30 30 30 30 30...

Страница 15: ...nx64 o directory Because LD_LIBRARY_PATH is a global setting it affects all binaries run within the shell where it is set In this case a library file is conflicting with a version required by awk The...

Страница 16: ...NAMC ZYNQ FMC Board Support Package Manual Version 1 0 N A T GmbH 16 Known bugs and restrictions There are no known bugs or restrictions yet...

Страница 17: ...com Petalinux 2 UG1144 Petalinux Tools Reference Guide https www xilinx com support documentation sw_m anuals petalinux2014_4 ug1144 petalinux tools reference guide pdf 3 IPMI FRU Storage Specificati...

Страница 18: ...Board Support Package Manual Version 1 0 N A T GmbH 18 Appendix B Document s History Revision Date Description Author 1 0 24 10 2016 initial release mm 1 1 15 05 2017 Added section Programing FMC FRU...

Отзывы: