background image

Europe Geographic Location Codes  

Portugal  

Morocco

  

Iceland  

Ireland  

Spain  

Albania  

Andorra  

Austria  

Belarous 

Belgium  

Bosnia and Herzegovina  

Bulgaria  

Croatia  

Czech Republic  

Denmark  

Estonia  

Faroe Islands  

Finland  

France  

Lyon & North 
South of Lyon 

Germany  

Frankfort & North 
South of Frankfort 

Gibraltar   

Algeria  

UK  

 

8
8
9

10 
10 

8
8
9
9

11 
11 
12
12

9
8

10

9
7

 

7
8
9

12
10 

8

11

9

11

9

7
9
8

10
12
10

7

 7

 

12
10

8

8
9
9
8

 

12
11

9
9

11
10 

Netherlands  

Belgium  

France  

Norway  

Sweden  

Denmark  

Germany  

Switzerland  

Czech Rep.  

Slovenia  

Italy  

13  

12  

Finland  

11  

Estonia  

Latvia  

10  

Poland

Slovakia  

Hungary  

Lithuania  

Serbia &  

8  

9  

Bosnia &

Herezgovinia  

Belarus  

Romania  

Montenegro  

Albania  

Greece  

Holy See (Vatican City)  

Hungary  

Iceland  

Ireland  

Italy 

Latvia 

Liechtenstein  

Lithuania  

Luxembourg  

Macedonia 

Malta  

Moldova 

Monaco  

Netherlands  

Norway  

Poland  

Portugal  

Romania

7  

Bulgaria  

Macedonia  

Greece  

6  

Ukraine  

Moldova  

Turkey  

Russia  

Russia  

Moscow & North 

South of Moscow 

Spain 

Madrid & North 

South of Madrid 

Serbia and Montenegro  

Slovakia  

Slovenia  

San Marino 

Sweden  

North of Stockholm 

Stockholm & South 

Switzerland  

Ukraine  

United Kingdom  

North of Newcastle 

Newcastle & South  

Croatia

Austria

Code

 

 

Code

  

Code

  

Country

Country

Country

Содержание HD150

Страница 1: ... ll see the battery compartment on the underside of the base of the scale lift and open see the enclosed drawing Fig1 the battery cover remove and or install the batteries Be sure that the batteries are installed correctly following the polarity indicators in the battery compartment Reinstall the battery cover OPERATION INSTRUCTIONS on the scale Either place the remote display box together with th...

Страница 2: ...is using standard professional calibration weights the other is the selection of 1 Press down the T key until the indicator displays GE Uxx GE oxx or GE FAC a GE Uxx means USA geographic location code xx is selected b GE FAC means Factory geographic location code is selected c GE oxx means Other except for USA and Factory geographic location code xx is selected 2 Press the M or D key to change the...

Страница 3: ...s internal calibration factors to compensate for variations in ferent weight at an end users local site than it did at the Calibration CAL site The scale maintains two gravity setting values one is local site gravity value the other is calibration site gravity value The scale will use the relationship between calibration and local gravity for its weight calculations We have compiled a list of loca...

Страница 4: ...rland Czech Rep Slovenia Italy 13 12 Finland 11 Estonia Latvia 10 Poland Slovakia Hungary Lithuania Serbia 8 9 Bosnia Herezgovinia Belarus Romania Montenegro Albania Greece Holy See Vatican City Hungary Iceland Ireland Italy Latvia Liechtenstein Lithuania Luxembourg Macedonia Malta Moldova Monaco Netherlands Norway Poland Portugal Romania 7 Bulgaria Macedonia Greece 6 Ukraine Moldova Turkey Russia...

Страница 5: ...rio North of Nakina Nakina South Saskatchewan 11 10 1 1 10 11 10 9 11 10 9 8 10 9 NunavutTerritory Manitoba Ontario 14 13 12 11 10 9 8 Quebec Ottawa Newfoundland Prince Edward Island New Brunswick Prince Edward Island Quebec Sept Iles South Saskatchewan North of Prince Albert Prince Albert South NorthwestTerritories Echo bay North South of Echo bay NunavutTerritory Victoria Island North BetweenVic...

Страница 6: ... Northwest of Lake Michigan Southeast of Lake Michigan Minnesota 16 15 16 15 16 15 15 14 12 18 15 17 17 16 18 Pennsylvania Rhode Island South Carolina South Dakota Tennessee Texas Northeast of Colorado River Southwest of Colorado River Utah Vermont Virginia Washington DC Washington State WestVirginia Wisconsin Green Bay North South of Green Bay Wyoming North of Casper Casper South 16 16 13 17 13 1...

Страница 7: ...almon River Mtns MT ND WY WA OR CA NV AZ UT CO NM TX SD NE 19 18 17 MN 16 15 14 IA OK KS WI MO AR 13 12 27 26 23 12 11 13 16 15 14 13 13 12 16 15 11 10 12 9 17 6 1 13 12 11 10 IL LA MS State Mississippi Kosciusko North South of Kosciusko Missouri Montana Helena North South of Helena Nebraska Nevada New Hampshire New Jersey New Mexico NewYork Albany North South of Albany North Carolina Raliegh Nort...

Страница 8: ...n available USB port on your computer 2 Power on the scale SETTING UP THE HD 300 FOR USE WITH THE UPS WORLDSHIP SOFTWARE USA CANADA ONLY Please note this function will not work in Europe 1 Open the UPSWorldship software and click on tools 2 Click on System Preferences ...

Страница 9: ...3 Click on Hardware in the drop down menu 4 Click on Scale Port drop down menu and choose USB ...

Страница 10: ...5 Click on ScaleType drop down menu and choose Toledo PS60 5155 150lb FlatTop 6 Click the Test Scale button ...

Страница 11: ...ll see the weight displayed in the weight OK to exit this screen On the next screen click OK again to exit to the main screen 8 Finally ensure that the box next to Electronic Scale Activated is checked Your scale is now set up and ready to use ...

Страница 12: ...d on a table SPECIFICATIONS Model HD150 HD300 Capacity 68kg 150lb 136kg 300lb Accuracy 0 02kg 0 05lb Units Platform dimension Display dimension ScaleWeight lb kg 0 05kg 0 1lb 355 5 x 355 5 x 63 5mm 14 x 14 x 2 5 165 x 82 5mm 6 5 x 3 25 3 4kg Operating temperature Power Source Optimum 10 40 C 50 104 f 6 0V 100 mA AC Power adaptor 4 x AA Batteries Load cell Battery compartment and cover www myweigh ...

Отзывы: