background image

SEM330

 

 

SEM330 and SEM370 are using the same main pcb board except the extra function. 
 

SEM330 basic version: 
has Micro SD-Card slot, Modbus RS-485, TCP/IP, 3 Phase 4-Line voltage input, 3 clamp connection 

terminal and extra sensor terminals. We also provide Battery clock back-up device.   

“B” type USB terminal is included. 

 

In case of TCP/IP, you can get web cloud service directly by connecting LAN cable (2-channel service 

is free)    30channel service is option. 
 

SEM330 optional items: 
*Temperature and humidity sensor 

*WIFI module   
*LORA module (FULL MESH networking service up to 100 channels)   

*Pressure sensor (0 to 10bar) 
*Dust sensor ( 3 channel) 

 
SEM330 have 5 push buttons and 3 led display but not useful except the following button. 

 
LED lamp: 

red led: power on indication 
 

SEM330 Piano switch on top side 

Please press the piano switch #3 before start the SEM330. 
 

If you are using WIFI module on SEM330, please press No. 5 button for WIFI pairing start. 
And press 3 seconds continuously, the green led lamp will blinking for WIFI pairing start.   

Содержание SEM330

Страница 1: ...SEM330 360 370 375 Energy Logger manual ...

Страница 2: ...rvice is free 30channel service is option SEM330 optional items Temperature and humidity sensor WIFI module LORA module FULL MESH networking service up to 100 channels Pressure sensor 0 to 10bar Dust sensor 3 channel SEM330 have 5 push buttons and 3 led display but not useful except the following button LED lamp red led power on indication SEM330 Piano switch on top side Please press the piano swi...

Страница 3: ...re which we provide free cost nevertheless if you see data please change the clamp connection position If you need to measure only single phase and 1 channel energy measuring please connect only N and T pole B type USB terminal If you connect 5V DC power SEM330 power is on and the clock is start to work In this case you can measure with optional sensors SEM330 Test Report dated on January 2019 by ...

Страница 4: ......

Страница 5: ...M370 3 Phase Energy Logger SEM370 basic version has Micro SD Card slot Modbus RS 485 TCP IP 3 Phase 4 Line voltage input 3 clamp connection terminal and extra sensor terminals We also provide Battery clock back up device ...

Страница 6: ...sh buttons and 3 led display LED lamp red led power on indication SEM330 Piano switch on top side Please press piano switch 3 before start the indicator if necessary If you want to measure Single phase but 3 channel application please make the cable as the above photo But if your cable connection method is reverse you can see data when you are using rs 485 software which we provide free cost never...

Страница 7: ...4 Line voltage connector with 4 line cables Please connect the RJ12 jack with 3 clamps on top of SEM370 case if you see data on lcd display please rotate the clamp connecting position SEM370 clamps SEM370 clamps must be ordered separately You must use the clamps which is confirmed by the We provide 30A 60A 100A 200A 500A clamps SEM370 LCD operation method SEM370 have 5 buttons MODE UP DOWN ENTER O...

Страница 8: ...r Factor Voltage Frequency ENERGY2 Active power W Total Energy power Wh or kWh Reactive Power AVR Apparent Power VA AVRh Vah COST GRAPH Daily and Monthly Energy cost calculation will be provided in the future We will also provide Daily Monthly Yearly graph in the future T H Temperature and Humidity Option Pressure sensor Option ...

Страница 9: ...433MHz Will be available in the future WIFI If you buy WIFI module and insert it onto the main pcb you can use WIFI mode Please move to WIFI mode and press the START icon and press the COMPLETE icon Then you could see the ENERGY1 lcd page and could see the green led is blinking continuously Then the WIFI pairing mode is starting now LAN Web cloud service Please connect the LAN cable on to the tcp ...

Страница 10: ...loud service automatically LANGUAGE Now we provide English mode only MODBUS RS 485 Please use the rs 485 software for to see the data AUTO SCROLL Will be available in the future ADMIN You can adjust the CT PT ratio with this mode RS 485 software operation method We supply RS 485 to USB adapter as below photo Please connect to and to by cable You must provide the cable ...

Страница 11: ...n starting the software please check the Port number is correct or not If it is okay please press the Open button then you could see the 30 kinds of data at once with 2 seconds interval If you are not satisfied you can change from 2 seconds to 200 seconds If you see figure on Active power W or kW please rotate the clamp position or change the voltage pole when you made mistake ...

Страница 12: ......

Страница 13: ...If you want to erase the PC software logged data please do the following action Setting Database Delete Data You can see the logged data is deleting ...

Страница 14: ...n and save the file to your wanted file position If you want to connect up to 30 channels of SEM370 you must memorize the Device Number by using RS 485 software Slave ID number setting as below Micro SD card data logging 1 minute interval data logging 1 month 1 file is saving now ...

Страница 15: ...ase press the ENTER button and you could see the unit is changing Electricity energy phase change You can change L1 L2 L3 3P phase by pressing the ENTER button If you have problem to connect R S T N 4 pole now due to the factory electricity line problem you can use 2 pole connect as below photo ...

Страница 16: ... you want to get 30 channel service please contact to Korins Inc directly Korins Inc www mywatt biz Phone 82 31 777 1588 Mobile 82 10 8905 1244 Email hyh korins kr 30 Channel web cloud service If the company or factory have problem with WIFI you can use 4G router instead Please connect I to TCP IP line as below photo ...

Страница 17: ...th your email address or company email address on this App site 1 Please log on the MYWATT30 app with your ID and password 2 Please select the NEW DEVICE icon and select the WIFI icon and select the SEM360 device 3 Please go to WIFI channel display mode on your smart phone 4 Please find and select the SEM370_XXX123 number which is matching your SEM370 serial number 5 After selection the above SEM3...

Страница 18: ...lease press NEXT icon until it stop the pairing process 11 If the pairing process is finishing please write an email or call a phone to Korins for to register the DEVICE number at the web server Korins staff will support on this final process SEM360 Model ...

Страница 19: ...M375 is suitable for wall mounting or stand type for the service staffs It has magnet on back side plastic part and could easily attach on to the steel plate SEM375 also have rechargeable battery for the clock backup ...

Страница 20: ...SEM375 and SEM370PRO 1 Graph Day Week Month Year You can change the date by up down key You can change the day week month year by using the Enter key 2 Chart Day Month Year Optional Graphic software MYWATT GRAPH 300 00 ...

Страница 21: ...Optional FEMS or BEMS software named Smart Electric Power Monitoring System Software ...

Страница 22: ...Optional sd card file software 300 00 You can see realtime hour day graph for W P F Ampere Voltage with this new software ...

Страница 23: ...David Hong chairman of MyWatt Inc Korins Inc http mywatt biz hyh korins kr 031 777 1588 010 8905 1244 ...

Страница 24: ......

Отзывы: