The DLX Datalogger offers a unique combination of functions that provide the 

features of a CAN interface, data acquisition module, and data logger all in one compact package. Different variations of 

the DLX are available. Additional channels are available depending upon the unit purchased. The standard DLX hardware 

provides the following: 

 

Connecting the DLX 

The DLX uses two D-Sub connections to handle all the sensor inputs, network communication and DC power during data 

acquisition and stand-alone data-logging. Connect to the PC using the USB cable to to configure the DLX and retreive MDF4 

data-log files. The wire diagram below shows the functions of break-out cables available for the DLX: 

 

 

 

Note:

 The DLX can be powered by USB cable or by COM cable using an external power supply/vehicle battery. 

 

 

 

Four 0 to 20 V single-ended analog inputs 

 

Four +/- 5 V differential analog inputs 

 

Four K-type thermocouple inputs 

 

Four digital input/output channels 

 

One 5 to 15 V sensor power output 

 

One ISO9141 K-Line channel 

 

Two high speed CAN 2.0B channels 

 

Removable SDHC memory card 

 

ASAM MDF4 file format 

 

 

Содержание DLX 1100 Series

Страница 1: ...ensor inputs network communication and DC power during data acquisition and stand alone data logging Connect to the PC using the USB cable to to configure the DLX and retreive MDF4 data log files The...

Страница 2: ...Public 2 DOC 000078 Connectivity I O Cable Part Number 150 0211 6FT DB26 to un terminated cables plus 4x K type connectors...

Страница 3: ...ls of all associated hardware devices and connections To build the device tree Right click on Computer in the device tree Click Add device Select USB Port from the list of Ports in the Select Device t...

Страница 4: ...ical errors USB Flashing Primary green Unit is receiving USB message Flashing Secondary yellow Unit is transmitting USB messages CAN 1 CAN 2 Flashing Primary green Unit is receiving CAN message Flashi...

Страница 5: ...easurement Range 200 C to 1372 C 328 F to 2501 F Max Sample Rate 10 Hz per channel Input Protection 36 V Sensor Power Supply Number of Channels 1 adjustable output 5 15 V 500 mW max load Adjustment St...

Страница 6: ...icators 1 Power 1 USB communication 2 CAN communication 1 K Line communication 1 LIN communication 1 Logger status Memory Storage Type User removable SDHC memory card with sealed cover 16 GB class 10...

Страница 7: ...ntrol Document Category Document Version Quick Start Guide 1 0 Release Type Status Public Draft Document Number Customer List Publish Date DOC 000078 All 2019 04 12 Subject DLX Datalogger Quick Start...